• 제목/요약/키워드: Multi-channel stimulation

검색결과 16건 처리시간 0.03초

다채널 진동자극이 체성감각에 미치는 영향 (Effect of Multi-Channel Vibration Stimulation on Somatosensory Sensibility)

  • 배태수;김형재;김솔비;장윤희;김신기;문무성
    • 한국정밀공학회지
    • /
    • 제28권6호
    • /
    • pp.651-656
    • /
    • 2011
  • Although prosthetic training was received, most of amputees mainly depend on visual feedback to use prostheses, not on cutaneous and proprioceptive sensibility. Our objective of this study was to determine if there are changes in the somatosensory sensibility of amputees compared to non-amputees using multi-channel vibration stimulation system. One transradial amputees and ten non-amputees were involved. To investigate changes of residual somatosensory sensibility at stump, we set up custom-made vibration stimulation system including eight actuators (4 medial and 4 lateral) and GUI-based acquisition system. The results showed that there was similar pattern of subjective response at most of channels among group as stimulation increases. However, amputees' subjective response at channel 8 for 238Hz vibration was more sensitive than that of healthy persons. With respect to channels, response at channel 4 (medial) corresponding region to flexor carpi ulnaris for transradial amputees was most sensitive than other channels. In addition, sensitivity of four medial channels was on average about 0.5 scale than that of four lateral channels. Somatosensory sensibility was amputee, women, and men in sensibility order.

다채널 전극을 이용한 초음파 자극 시 쥐 해마 신경 세포의 활동 전위 검출 (Modulation in Action Potentials of Rat Hippocampal Neurons Measured on Multi-Channel Electrodes During Ultrasound Stimulation)

  • 한희석;전현재;황서영;이예나;변경민;전상범;김태성
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권4호
    • /
    • pp.177-181
    • /
    • 2013
  • It is known that ultrasound affects action potentials in neurons, but the underlying principles of ultrasonic neural stimulation are not clearly elucidated yet. In this study, we measured the action potentials of rat hippocampal neurons cultured on multi-electrode arrays during ultrasound stimulation. From most of electrodes, it was observed that the ultrasound stimulation increased the frequencies of action potentials (i.e., spikes) during ultrasound stimulation.

소규모 전원장치를 이용한 다채널 자기 신경자극 시스템 (Multi-Channel Magnetic Nerve Stimulation System with Small Size Power Supplies)

  • 한병희;김기왕;이세호;조민형;이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권2호
    • /
    • pp.139-144
    • /
    • 2001
  • 자기 신경자극기는 신경의학, 재활의학을 포함한 많은 임상의학 분야에서 널리 쓰이고 있다. 자기 신경자극기는 전력소모가 크고 고압 전원이 필요한 이유 때문에 단채널 시스템만이 임상환경이나 연구환경에서 쓰여 왔었다. 본 논문에서는 4채널 자기 신경자극기 개발을 소개하였다. 고압 커패시터를 충전하는데 있어서 단계적 충전방식을 사용하여 작은 크기의 직류 전원장치로 다채널 시스템을 구현하였고, 채널별로 서로 다른 자극 프로토콜로 자극 코일을 구동할 수 있는 다채널 제어시스템을 구성하였다. 개발된 시스템은 신경계통 장애가 있는 환자들의 재활이나 자기적인 침술 등 다양한 기능적 자기 자극에 활용될 수 있을 것으로 기대된다.

  • PDF

근막통증증후군의 통증유발점 치료를 위한 멀티어레이 전극과 프로그램 가능한 다채널 전기자극기 개발 (Development of Multi-Array Electrode and Programmable Multi-channel Electrical Stimulator for Firing Trigger Point of Myofascial Pain Syndrome)

  • 김수홍;김수성;전계록
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.221-227
    • /
    • 2015
  • In this study, Multi-Array Electrodes (MAE) and Programmable Multi-channel Electrical Stimulator (PMES) were implemented for firing Trigger Points (TPs) of the patient with Myofascial Pain Syndrome (MPS). MAE has 25 Ag/AgCl electrodes arranged in the form of array ($5{\times}5$) fabricated with flexible pad, which are applicable to be easy-attached to curved specific region of the human body. PMES consisted of 25 channels. Each channel was to generate various electric stimulus patterns (ESPs) by changing the mono-phasic or bi-phasic of ESP, On/Off duration of ESP, the interval between ESP, and amplitude of ESP. PMES hardware was composed of Host PC, Stimulation Pattern Editing Program (SPEP), and Multi-channel Electrical Stimulator (MES). Experiments were performed using MAE and PMES as the following. First experiment was performed to evaluate the function for each channel of Sub- Micro Controller Unit (SMCU) in MES. Second experiment was conducted on whether ESP applied from each channel of SMCU in PMES was focused to the electrode set to the ground, after applying ESP being output from each channel of SMCU in PMES to MAE.

A Multi-photodiode Array-based Retinal Implant IC with On/off Stimulation Strategy to Improve Spatial Resolution

  • Park, Jeong Hoan;Shim, Shinyong;Jeong, Joonsoo;Kim, Sung June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권1호
    • /
    • pp.35-41
    • /
    • 2017
  • We propose a novel multi-photodiode array (MPDA) based retinal implant IC with on/off stimulation strategy for a visual prosthesis with improved spatial resolution. An active pixel sensor combined with a comparator enables generation of biphasic current pulses when light intensity meets a threshold condition. The threshold is tuned by changing the discharging time of the active pixel sensor for various light intensity environments. A prototype of the 30-channel retinal implant IC was fabricated with a unit pixel area of $0.021mm^2$, and the stimulus level up to $354{\mu}A$ was measured with the threshold ranging from 400 lx to 13120 lx.

The Comparisons of 4 Channel Auditory Brainstem Response for Tracking Auditory Neuro-Pathway

  • Woo, Jin-Wan;Lee, Sang-Min;Hong, Sung-Hwa;Sung, Young-Ju;Park, Sook-Kyoung;Lee, Yong-Hee;Kim, In-Young;Kim, Sun-I.
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권3호
    • /
    • pp.195-200
    • /
    • 2004
  • The Auditory Brainstem Response (ABR) with a click stimulation in guinea pigs was used to examine the auditory neuro-pathway from the cochlear nucleus to brain. Using multi-channel active electrodes, the 3-dimensional auditory pathway was examined from the cochlea to the inferior colliculus through the brainstem. These results are similar to the well-known neuro-pathway. This study on the multi-channel ABR shows that the positions of the ABR generators move to the central brain and the contralateral pathway. It is generally agreed that the ABR is generated by some structures along the auditory pathway. This study provides some information on the neuro-pathway where the ABR peak is generated.

체내 이식 기기용 표준 CMOS 고전압 신경 자극 집적 회로 (A High-Voltage Compliant Neural Stimulation IC for Implant Devices Using Standard CMOS Process)

  • 알피안 압디;차혁규
    • 전자공학회논문지
    • /
    • 제52권5호
    • /
    • pp.58-65
    • /
    • 2015
  • 본 논문에서는 신경 관련 인공 전자기기를 위한 신경 자극 집적회로를 $0.18-{\mu}m$ 표준 CMOS 반도체 공정을 이용하여 설계하였다. 제안 된 신경 자극 회로는 12.8-V 전원을 사용하면서 $10-k{\Omega}$의 부하에 최대 1 mA의 전류까지 전달이 가능하다. 표준 CMOS 공정 기술로 구현을 위해서 저전압 트랜지스터만을 이용하여 설계를 하였고, 고전압에서의 안정적인 동작을 위하여 트랜지스터 스태킹 기술을 적용하였다. 또한, 신경 자극 동작 후 전하 잔여량이 남아 있지 않도록 active charge balancing회로를 포함하였다. 제안 된 단일 채널 자극 집적회로의 경우 디지털-아날로그 변환기, 전류 출력 드라이버, 레벨 시프터, 디지털 제어 부분, 그리고 active charge balancing 회로까지 모두 포함하여 전체 칩 레이아웃 면적은 $0.13mm^2$을 차지하며, 다중 채널 방식의 신경 자극 기능의 체내 이식용 인공 전자기기 시스템에 적용을 하는데 적합하다.

STN DBS of Advanced Parkinson's Disease Experienced in a Specialized Monitoring Unit with a Prospective Protocol

  • Lee, Ji-Yeoun;Han, Jung-Ho;Kim, Han-Joon;Jeon, Beom-Seok;Kim, Dong-Gyu;Paek, Sun-Ha
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권1호
    • /
    • pp.26-35
    • /
    • 2008
  • Objective : In the evaluation of patients with Parkinson's disease (PD), most neurologists only see their patients during a limited period of their fluctuating 24-hour-a-day lives. This study aimed to assess the short-term outcome of STN stimulation for patients with advanced PD evaluated in a 24-hour monitoring unit for movement disorder (MUMD) using a prospective protocol. Methods : Forty-two patients with advanced PD consecutively treated with bilateral STN stimulation using multi-channel microelectrode recording were included in this study. All patients were evaluated using a 24-hour MUMD with a video recording/editing system and were evaluated with a prospective protocol of the Unified Parkinson's Disease Rating Scale, Hoehn and Yahr Staging, Schwab and England Activities of Daily Living, levodopa equivalent daily dose (LEDD), Short Form-36 Health Survey, and neuropsychological tests. Magnetic resonance (MR) images of the brain were performed prior to and six months after surgery. Results : All patients were evaluated at three and six months after surgery. There was a rapid and significant improvement of the motor symptoms, especially in tremor and rigidity, after STN stimulation with low morbidity. Dyskinesia was markedly decreased with much lowered LEDD values by 50% after STN stimulation. 1.5T MR images were safely taken according to the manufacturer's guidelines at six months after surgery without any adverse effects in 41 patients treated with STN stimulations. Conclusion : Evaluations in a 24-hour monitoring unit could reduce the dose of medication efficiently to an optimal level with patients' comfort and improve the clinical symptoms in harmony with STN stimulation.

전기자극 변조방식이 체성감각에 미치는 영향 (Effects of Modulation Type on Electrically-Elicited Tactile Sensation)

  • 황선희;아라 조샨;송동진;배태수;박상혁;강곤
    • 한국정밀공학회지
    • /
    • 제29권7호
    • /
    • pp.711-716
    • /
    • 2012
  • The purpose of this study was to investigate how the modulation method affects the effectiveness of eliciting tactile sensations by electrical stimulation. Two methods were employed and the results were compared and analyzed; pulse amplitude modulation (PAM) and pulse width modulation (PWM). Thirty-five healthy subjects participated in the experiments to measure the stimulation intensity that began to elicit a tactile sensation - activation threshold (AT). Constant-current monophasic rectangular pulse trains were employed, and the stimulation intensity was varied from zero until the subject felt any uncomfortable sensation. The step size of the stimulation intensity was 100nC/pulse. After each experiment, the subject described the sensation both quantitatively and qualitatively. The two modulation methods did not make a significant difference as far as the AT values were concerned, but most of the subjects showed 'intra-individual' consistency. Also, it was confirmed that our range of the stimulation parameters enabled us to obtain three major tactile sensations; tickling, pressure and vibration. The results suggested that the stimulation parameters and the modulation type should be selected for each individual and that selective electrical stimulation of the mechanoreceptors needs more diversified researches on the electrode design, multi-channel stimulation protocol, waveforms of the pulse train, etc.