• 제목/요약/키워드: Multi-Point

검색결과 2,352건 처리시간 0.029초

멀티레터레이션법을 이용한 절대간섭계의 점광원 위치 결정법 (Position Determination Using Multi-lateration Method)

  • 김병창
    • 제어로봇시스템학회논문지
    • /
    • 제12권9호
    • /
    • pp.856-860
    • /
    • 2006
  • A CCD camera is used to determine the position of the point sources that influence the measurement accuracy in the absolute interferometer. The principle of determination method is based on the GPS in which the position is determined by more than 3 distance information from the known positions. Two-dimensional array of photo-detectors in the CCD camera is used as known positions. Performing optimization of the cost function constructed with phase values measured at each pixel on the CCD camera, the position coordinates of each source is precisely determined.

다파장 IR-heater를 이용한 재작업 장치 설계 (Design of Rework Device using Multi-wave IR-heater)

  • 조도현
    • 전자공학회논문지 IE
    • /
    • 제47권1호
    • /
    • pp.6-11
    • /
    • 2010
  • 본 논문은 다파장 IR-heater를 이용하여 전자부품을 솔더령 하거나 또는 회로기판으로부터 분리를 하는 전자회로기판 수리장치에 관한 설계를 다룬다. 이 IR 수리 장치는 IR-heater를 이용하여 납땜의 용융온도 설정에 따라 안정한 온도 제어 아래 목표 영역의 온도를 중가시킨다. 이렇게 설계된 시스템은 PCB와 실장된 소자에 어떠한 열 손상을 주지 않는다. 그 성능융 실험을 통해 평가한다.

Nanometric Positioning Over a One-Millimeter Stroke Using a Flexure Guide and Electromagnetic Linear Motor

  • Fukada, Shigeo;Nishimura, Kentaro
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권2호
    • /
    • pp.49-53
    • /
    • 2007
  • In this study, we investigated experimentally the potential of a planer positioning mechanism with three degrees of freedom using a flexure guide and an electromagnetic linear motor. The goal was to produce a multi-axis positioning system with nanometric resolution over a 1-mm stroke. An $X-Y-\theta$ stage was designed based on previous results from a single-axis prototype and was constructed with a flexure guide mechanism and voice coil motor type linear actuators. We examined the necessity of a driving method and control system to ensure high resolution for multi-axis positioning. Experiments were conducted to evaluate the performance, and the results confirmed the mechanism's potential; fine point-to-point (PTP) positioning was achieved over a 1-mm stroke, with a resolution of 2 nm for translation in X-Y and 0.01 asec for yaw in $\theta$.

열전달 질량유량계 개발 (Development of Thermal Mass Flow Meter)

  • 지대성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.118-122
    • /
    • 1999
  • Thermal mass flow meter was developed using principle of convective heat transfer. The advantage of thermal mass flow meter is measuring mass flow directly, therefore, it is not required to use densitometer or temperature/pressure and DP gages. The final accuracy of this thermal mass flow meter is $\pm1.0{\%}$ or better, reproducibility is $\pm0.2{\%}$, and the response time is 600 ms. The thermal mass flow meter was developed from a single point to multi-points (maximum is 9 points), and the number of points is determined according to desired accuracy and size of piping/duct. Since this thermal mass flow meter adopted microprocessor based design, it is intrinsically accurate, self-error detectable, and has self-diagnosis function. The applications of this thermal mass flow meter are for measurement and control of HVAC air flow, other gas flow, and liquid flow.

  • PDF

Joint Transmission 기반의 LTE-Advanced 시스템에 대한 호 수락 제어의 성능 분석 (Analysis of Call Admission Control for Joint Transmission-Based LTE-Advanced Systems)

  • 김승연;이형우;류승완
    • 한국통신학회논문지
    • /
    • 제38B권7호
    • /
    • pp.535-542
    • /
    • 2013
  • Coordinated multi-point transmission (CoMP) is considered to be a promising technique to improve the throughput for LTE-Advanced systems. One important approach for CoMP is Joint Transmission (JT). However, the analytical model of JT has not been fully studied, as user equipments (UEs) receiving the desired signals from an adjacent base station (BS) as well as serving BS, or only serving BS were not distinguished. We derive a new analytical model to describe the call admission control in JT based systems. The performance measures of interest are the call blocking probability, and resource utilization. Furthermore, we compare the performance of JT-based systems and non-JT- based systems. The analytical results are in reasonable agreement with the simulation results.

Performance Evaluation of Coordinated Multi-Point Transmission and Reception in Indoor Mobile Communication Systems

  • Lee, Woongsup;Lee, Howon
    • Journal of information and communication convergence engineering
    • /
    • 제11권3호
    • /
    • pp.167-172
    • /
    • 2013
  • Recently, mobile communication systems are suffering from exponentially increasing data traffic. As a promising solution to the increase in data traffic, a coordinated multi-point transmission and reception (CoMP) scheme has been proposed. Although a great deal of research has been done on this new technology, the performance of mobile communication systems with CoMP has not been evaluated properly in a typical indoor environment. To address this, we have developed a system-level simulator and evaluated the performance of mobile communication systems with CoMP. Unlike previous works, we have used an actual antenna pattern in our simulator and link-level results are properly taken into account through link-level abstraction. By using a system-level simulator, we have evaluated the performance of mobile communication systems with CoMP in an indoor environment and found that unlike an outdoor cellular environment, CoMP may not improve the performance of overall mobile communication systems in an indoor environment.

Analysis of Generalized n-winding Coupled Inductor in dc-dc Converters

  • Kang, Taewon;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.88-89
    • /
    • 2017
  • This paper investigates the design of multi-winding coupled inductor for minimum inductor current ripple in rapid traction battery charger systems. Based on the general circuit model of multi-winding coupled inductor together with the operating principles of dc-dc converter, the relationship between the ripple size of inductor current and the coupling factor is derived under the different duty ratio. The optimal coupling factor which corresponds to a minimum inductor ripple current becomes -(1/n-1), i.e. a complete inverse coupling without leakage inductance, as the steady-state duty ratio operating point approaches 1/n, 2/n, … or (n1)/n. In an opposite manner, the optimal coupling factor value of zero, i.e. zero mutual inductance, is required when the steady-state duty ratio operating point approaches either zero or one.

  • PDF

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

  • Jung, Chae-Kyun;Jung, Yeon-Ha;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.628-634
    • /
    • 2014
  • This paper investigates the transient characteristics of grounding systems used in under-ground distribution power cables. Recently, two kinds of grounding system are used for underground distribution cables in Korea. The first one is conventional multi-point grounding system, the other is newly proposed non-bundled common grounding system. The non-bundled common grounding system has an advantage the decreasing the power loss due to decrease of the shield circulation current. In this paper, the lightning overvoltage induced in neutral wire (in case of non-bundled common grounding system, overvoltage between opened neural wires and grounding in each phase) of these two kinds of grounding systems are estimated and compared by field tests and EMTP simulations. The EMTP simulation methods are firstly verified by comparison of measurement and simulation. Finally, the insulation level against lightning is expected by EMTP simulation results using verified model.

Analysis of Macro-Diversity in LTE-Advanced

  • Kim, Gun-Yeob Peter;Lee, Jung-Ah C.;Hong, Sang-Jin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제5권9호
    • /
    • pp.1596-1612
    • /
    • 2011
  • Coordinated Multi-Point (CoMP) transmission / reception is being studied in Long Term Evolution-Advanced (LTE-A) for future evolution of the $3^{rd}$ Generation Partnership Project (3GPP) LTE. Support of soft handover is essential for improving the performance of cell edge users. CoMP provides a natural framework for enabling soft handover in the LTE system. This paper evaluates the soft handover gain in LTE-A downlink. Mathematical analysis of signal to interference plus noise ratio (SINR) gain and the handover margins for soft handover and hard handover are derived. CoMP system model is developed and an inter-cell and intra-cell interference model is derived, taking into account the pathloss, shadowing, cell loading, and traffic activity. Reference signal received power (RSRP) is used to define the triggers and the measurements for soft handover. Our results indicate that parameter choices such as handover margin and the CoMP set size impact CoMP performance gain.

Robust Hcontrol applied on a fixed wing unmanned aerial vehicle

  • Uyulan, Caglar;Yavuz, Mustafa Tolga
    • Advances in aircraft and spacecraft science
    • /
    • 제6권5호
    • /
    • pp.371-389
    • /
    • 2019
  • The implementation of a robust $H_{\infty}$ Control, which is numerically efficient for uncertain nonlinear dynamics, on longitudinal and lateral autopilots is realised for a quarter scale Piper J3-Cub model accepted as an unmanned aerial vehicle (UAV) under the condition of sensor noise and disturbance effects. The stability and control coefficients of the UAV are evaluated through XFLR5 software, which utilises a vortex lattice method at a predefined flight condition. After that, the longitudinal trim point is computed, and the linearization process is performed at this trim point. The "${\mu}$-Synthesis"-based robust $H_{\infty}$ control algorithm for roll, pitch and yaw displacement autopilots are developed for both longitudinal and lateral linearised nonlinear dynamics. Controller performances, closed-loop frequency responses, nominal and perturbed system responses are obtained under the conditions of disturbance and sensor noise. The simulation results indicate that the proposed control scheme achieves robust performance and guarantees stability under exogenous disturbance and measurement noise effects and model uncertainty.