• Title/Summary/Keyword: Multi-Hazard

Search Result 214, Processing Time 0.034 seconds

Chinese buffer material for high-level radiawaste disposal --Basic features of GMZ-l

  • WEN Zhijian
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.236-244
    • /
    • 2005
  • Radioactive wastes arising from a wide range of human activities are in many different physical and chemical forms, contaminated with varying radioactivity. Their common feature is the potential hazard associated with their radioactivity and the need to manage them in such a way as to protect the human environment. The geological disposal is regarded as the most reasonable and effective way to safely disposal high-level radioactive wastes in the world. The conceptual model of geological disposal in China is based on a multi-barrier system that combines an isolating geological environment with an engineered barrier system. The buffer is one of the main engineered barriers for HLW repository. The buffer material is expected to maintain its low water permeability, self-sealing property, radio nuclides adsorption and retardation property, thermal conductivity, chemical buffering property, overpack supporting property, stress buffering property over a long period of time. Benotite is selected as the main content of buffer material that can satisfy above. GMZ deposit is selected as the candidate supplier for Chinese buffer material of High Level Radioactive waste repository. This paper presents geological features of GMZ deposit and basic property of GMZ Na bentonite. GMZ bentonite deposit is a super large scale deposits with high content of Montmorillonite (about $75\%$) and GMZ-l, which is Na-bentonite produced from GMZ deposit is selected as reference material for Chinese buffer material study.

  • PDF

Prevalence and antimicrobial resistance of Salmonella spp. and Escherichia coli isolated from ducks in Korea

  • Kim, Hyobi;Lee, Jiyoung;Jang, Yangho;Chang, Byungjoon;Kim, Aeran;Choe, Nonghoon
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.2
    • /
    • pp.91-95
    • /
    • 2016
  • This study was conducted to investigate the prevalence and antimicrobial resistance of Salmonella spp. and Escherichia (E.) coli isolated from ducks in Korea. A total of 400 cecal content samples were collected from 40 duck farms in Korea. Isolated Salmonella spp. and E. coli strains were 83 and 364 of the 400 cecal samples, respectively. The most prevalent serotype among the 83 Salmonella isolates was Salmonella Typhimurium (51 isolates: 61.45%). Resistance to the tested antimicrobial agents by Salmonella isolates was low except for erythromycin, while the resistance of the E. coli isolates to the other tested antimicrobial agents was high and 90.9% (331/364) of E. coli isolates showed multi-antimicrobial resistance. Antimicrobial resistance in duck zoonotic pathogens should be of concern to the Korean duck industry, as these pathogens exhibit a high rate of antimicrobial resistance and pose a potential hazard to public health.

Damage assessment and performance-based seismic design of timber-steel hybrid shear wall systems

  • Li, Zheng;He, Minjuan;Li, Minghao;Lam, Frank
    • Earthquakes and Structures
    • /
    • v.7 no.1
    • /
    • pp.101-117
    • /
    • 2014
  • This paper presents a reliability-based analysis on seismic performance of timber-steel hybrid shear wall systems. Such system is composed of steel moment resisting frame and infill wood frame shear wall. The performance criteria of the hybrid system with respect to different seismic hazard levels were determined through a damage assessment process, and the effectiveness of the infill wood shear walls on improving the seismic performance of the hybrid systems was evaluated. Performance curves were obtained by considering different target non-exceedance probabilities, and design charts were further established as a function of seismic weight. Wall drift responses and shear forces in wood-steel bolted connections were used as performance criteria in establishing the performance curves to illustrate the proposed design procedure. It was found that the presence of the infill wood shear walls significantly reduced the non-performance probabilities of the hybrid wall systems. This study provides performance-based seismic evaluations on the timber-steel hybrid shear walls in support of future applications of such hybrid systems in multi-story buildings.

Study on Establish of Multi-Hazard Map in Urban Area (도시지역에서의 멀티 해저드 맵 구축을 위한 연구)

  • Kim, Yeon Joong;Yoon, Jung Sung;Tanaka, Kohji
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.17-17
    • /
    • 2015
  • 세계적으로 최근 국지적 호우에 의한 홍수 및 토사재해가 빈번히 발생하여 인적피해 및 자산피해가 급증하고 있다. 일반적으로 강우에 의해 홍수가 발생되며 하안 및 하천 구조물에 피해를 주는 동시에 월파 및 제방이 붕괴되어 하천에서 제내지로 범람하여 범람피해가 발생된다. 하지만 도시지역에서 발생되는 강우는 불투수 면적비율이 비교적 커 다른 지역보다 최대 침수심이 발생되는 시간이 매우 빠르게 도달하는 환경적 특징이 있다. 또한 선상지 지역에 발달된 도시는 어느 동일한 강우사상에 의해 발생되는 내 외수 범람재해 및 토사재해가 동시에 발생되어 피해가 중첩될 가능성이 매우 크며 피해 리스크 또한 증가하고 있는 추세이다. 따라서 이상기후에 의해 발생되는 재해경감을 위해 기존의 대책 및 새롭게 구축되는 해저드 맵에 대해서 이와 같은 여러 재해 발생 가능성을 충분히 고려된 멀티 해저드 맵 구축이 필요하다. 본 연구에서는 일본 오노시의 지역방재계획을 위한 통합적인 해저드 맵 구축을 위해 내 외수 범람에 의한 피해 및 토석류 발생에 의한 영향평가를 실시하여 두 재해가 동시에 발생 가능한 지역을 대상으로 멀티 해저드 맵 구축 및 피난계획 수립을 목적으로 최근 발생되는 국지적 호우에 대한 예측을 위해 아직 검토대상 지역에 발생하진 않았지만 발생 가능한 강우사상을 추출하기 위해 DAD 분석을 실시하여 가능최대강우량을 산정하여 외력조건으로 사용하였다. 뿐만 아니라 토석류 모델의 현장 적용성 평가를 위해 2011년에 발생된 우면산 토석류 재해를 대상으로 비교 검토를 실시하였으며 본 논문의 주요한 결과를 아래와 같이 나타내었다.

  • PDF

Identifying Hazard of Fire Accidents in Domestic Manufacturing Industry Using Data Analytics (국내 제조업 화재사고 데이터 분석을 통한 복합 유해·위험요인 확인)

  • Kyung Min Kim;Yongyoon Suh;Jong Bin Lee;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.23-31
    • /
    • 2023
  • Revising the Occupational Safety and Health Act led to enacting and revising related laws and systems, such as placing fire observers in hot workplaces. However, the operating standards in such cases are still ambiguous. Although fire accidents occur through multiple and multi-step factors, the hazards of fire accidents have been identified in this study as individual rather than interrelated factors. The aim has been to identify multiple factors of accidents, outlining fire and explosion accidents that recently occurred in the domestic manufacturing industry. First, major keywords were extracted through text mining. Then representative accident types were derived by combining the main keywords through the co-word network analysis to identify the hazards and their relationships. The representative fire accidents were identified as six types, and their major hazards were then addressed for improving safety measures using the identification of hazards in the "Risk Assessment" tool. It is found that various safety measures, such as professional fire observers' training and clear placement standards, are needed. This study will provide useful basic data for revising practical laws and guidelines for fire accident prevention, system supplementation, safety policy establishment, and future related research.

Analysis of Spatial Characteristics of Old Building Districts in Daegu to Evaluate Fire Risk Factors (화재위험요소의 도출을 위한 대구지역 노후건축지구의 공간특성분석)

  • Son, Byeung-Hun;Kang, Kyung-Ha;Ryu, Jung-Rim;Roh, Seung-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.202-203
    • /
    • 2021
  • The proportion of old buildings over 30 years old increased from 29.0% in 2005 to 37.8% in 2019. These old buildings were created during the absence of building-related safety standards such as fire safety performance. In the process of use, illegal changes and extensions were made, making them more vulnerable to safety. In the 1st Basic Plan for Fire Safety Policy, among the 12-Key Tasks, one is to ensure the safety of residential living spaces. Fire safety investigations are being conducted to prevent large-scale disasters such as multi-use buildings, but no investigation has been conducted at the regional district level where small-scale old buildings are concentrated. Therefore, in order to derive fire risk factors in the old building district where old buildings are concentrated, the composition characteristics of the buildings were first analyzed.

  • PDF

Assessment of steel structures designed for progressive collapse under localized fires

  • Behrouz Behnam
    • Steel and Composite Structures
    • /
    • v.46 no.2
    • /
    • pp.279-292
    • /
    • 2023
  • Structural design against the progressive collapse has been a vital necessity for decades due to occasional tragic events. The question of whether designed structures against the progressive collapse are still robust if subjected to multi-hazard scenarios containing column removal and successive localized fires is ad-dressed in the current study. Two seven-story steel structures with an identical area but different structural configurations of 4- and 5-bays are designed against the progressive collapse; the structural components are also fireproofed for a 60 min fire resistance. The structures are then subjected to different column re-moval scenarios over different stories followed immediately by localized fires. Results indicate that the structures are not able to keep their stability under all of the considered scenarios; the 4-bay structure is more vulnerable than the 5-bay structure. It is also indicated that upper stories are more sensitive toward the considered scenarios than lower stories. To advance structural safety, two strategies are adopted: in-creasing the thickness of the insulation materials to reduce the thermal effects, or, increasing the safety fac-tor (ΩN) of the structures when designing against the progressive collapse. As for the first strategy, provid-ing a 35% and a 25% increase in the insulation thicknesses of the structural components of the 4-bay and 5-bay structures, respectively, can prevent a progressive collapse to trigger. As for the second strategy, in-creasing ΩN by 10% can enhance the structural integrity to where no collapse occurs under all of the sce-narios.

Monitoring and Risk Assessment of Pesticide Residues in School Foodservice Agricultural Products in Gwangju Metropolitan Area (광주광역시 학교급식 농산물의 잔류농약 모니터링 및 위해평가)

  • Kim, Jinhee;Lee, Davin;Lee, Mingyou;Ryu, Keunyoung;Kim, Taesun;Gang, Gyungri;Seo, Kyewon;Kim, Jung-Beom
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.283-289
    • /
    • 2019
  • This study was performed to monitor the residual pesticides in agricultural products used in school foodservice in the Gwangju metropolitan area. Risk assessment was also carried out based on the amount of agricultural products consumed. A total of 320 agricultural products supplied to schools in Gwangju were analyzed from 2015 to 2017. The pre-treatment and residual pesticide analysis of these products was conducted in accordance with the second method for multi-residue analysis of pesticides in the Korean food code. The hazard index was calculated by dividing the estimated daily intake (EDI) of pesticides by the acceptable daily intake (ADI). The linearity correlation coefficient for the calibration curve was 0.9923 to 1.0000, LOD 0.004 to 0.019 mg/kg, LOQ 0.012 to 0.057 mg/kg, and recovery was 79.1 to 100.2%. Residual pesticides were detected in 18 (5.6%) of 320 agricultural products used for school foodservice, and one sample of sweet potato stem (0.3%) exceeded the maximum residual limit (MRL). The detection frequency for chili peppers and bell peppers was higher than that for other agricultural products. The frequently-detected pesticides were boscalid and acetamiprid. These results showed that residual pesticide management is needed for chili pepper, bell pepper and sweet potato stem among agricultural products supplied to schools. The hazard index of bifenthrin in sweet potato stem showed the highest (64.18%), and the other pesticides were 0.03-8.23%. These results indicated that agricultural products supplied to schools in Gwangju were safe for consumption. To minimize the intake of residual pesticides, it is necessary to not only thoroughly wash agricultural products but to also ensure the expanded supply of products that are pesticide-free.

A Study on the External Evacuation System for Large-scale Fire of Multi-use Facilities (다중밀집시설 대형화재 외부대피 체계에 관한 연구)

  • Kim, Jung-Gon;Jeong, Min-Su;Jung, Jae-Wook
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.129-145
    • /
    • 2022
  • Purpose: This study aims at preparing an external evacuation system by setting up situation that may occur outside buildings in case of large-scale fire at buildings such as multiuse facilities and presenting appropriate response procedures and action instructions for evacuees and facility managers. Method: Major matters are summarized based on various situations which may occur outside in case of fire and the contents of fire manual. Necessary factors including risk alert standards in the event of fire and the role of building occupants are classified and then important issues are summarized. In addition, the definition of fire-related outside shelters and external evacuation routes are showed, and then the applicability to the shelters and the routes are reviewed for old apartments in Jung-gu among multi-dense facilities. Result: Four stages (attention, caution, alert, serious) for standards of fire risk warning are established with the results of the investigation and analysis, and guidelines for behavior for evacuees, facility owners, residents, managers are summarized and presented. In addition, the concept and role of external shelters are divided into primary to the third shelters, and matters related to the definition of each shelter and the establishment of evacuation routes are presented, and then considered them carefully. Conclusion: This study has highlighted the importance of suggesting a systematic plan to secure the safety for evacuees outside space of buildings with disorder and difficulty to control in the event of fire. Therefore, we are confident that it will be useful in making an integrated manual for inside and outside buildings.

Implications of Emphysema and Lung Function for the Development of Pneumonia in Patients with Chronic Obstructive Pulmonary Disease

  • Hong, Yoonki;Lee, Jae Seung;Yoo, Kwang Ha;Lee, Ji-Hyun;Kim, Woo Jin;Lim, Seong Yong;Rhee, Chin Kook;Lee, Sang-Do;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.79 no.2
    • /
    • pp.91-97
    • /
    • 2016
  • Background: Chronic obstructive pulmonary disease (COPD) is sometimes complicated with pneumonia, but little is known about the risk factors that promote the development of pneumonia in COPD. These risk factors were evaluated in the present study. Methods: The data of 324 patients with COPD from a prospective multi-center observational cohort with obstructive lung disease were evaluated retrospectively. To identify risk factors for the development of pneumonia in COPD, the clinical and radiological data at enrollment and the time to the first episode of pneumonia were analyzed by Cox proportional hazard analysis. Results: The median follow-up time was 1,099 days and 28 patients (8.6%) developed pneumonia. The Cox analysis showed that post-bronchodilator forced expiratory volume in one second ($FEV_1$, % of predicted) and the computed tomography (CT) emphysema extent (inspiratory V950) were independent risk factors for the development of pneumonia (post-bronchodilator $FEV_1$: hazard ratio [HR], 0.97; 95% confidence interval [CI], 0.94-1.00; p=0.048 and inspiratory V950: HR, 1.04; 95% CI, 1.01-1.07; p=0.01). Conclusion: Emphysema severity measured by CT and post-bronchodilator $FEV_1$ are important risk factors for the development of pneumonia in COPD.