• 제목/요약/키워드: Multi line

검색결과 1,691건 처리시간 0.047초

다기능 표면실장기의 공정계획 프로그램 개발 (Development of the Process Planning Program for a Multi-functional Surface Mounting Device)

  • 손진현;유성열;강장하;박성수;오병준;성필영
    • 산업공학
    • /
    • 제10권1호
    • /
    • pp.155-167
    • /
    • 1997
  • The purpose of this study is to develop the program for efficient operation of a multi-functional surface mounting device(SMD) which mount various components on a printed circuit board(PCB). These components are provided by diverse types of feeders such as cassette, stick and tray feeders. The SMD has one or two heads. In the SMD, the positions of PCB and feeders and fixed, and the head moves to pick up a component from a feeder and to mount it on the PCB. The number of lanes occupied by each feeder and the nozzle used for each component can be different. We develop an off-line program to minimize the cycle-time of the SMD by studying the optimal assignment of feeders and the optimal mounting sequence of components. Graphical User Interface(GUI) is also developed. Additionally, we consider the line balancing problem which appears when two SMDs are used sequentially.

  • PDF

AT 급전계통 전기철도 해석 알고리즘 연구 (A study on algorithm of AT feeding systems)

  • 추동욱;김재철;김낙경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1226-1228
    • /
    • 2001
  • In this paper, the modified simulation algorithms of the Auto Transformer (AT) feeding electric train were proposed. To obtain terminal voltage of train by using equivalent circuit of the AT feeding system, the iterative method is proposed for which determine the train voltages. The train voltages are iteratively calculated from the system voltage drop and line impedance. In the case study, the proposed method is verified from actual operation data of the Kwa-Chon line. Also it is verified that the proposed method can be extent to the multi-train simulation tool. The terminal voltage of the multi-train can be calculated by using superposition principle and it is easily applied to the proposed method. Therefore, the proposed method can be a solution for the complexity of the circuit analysis in the existing methods.

  • PDF

Development of wind tunnel test model of mid-rise base-isolated building

  • Ohkuma, Takeshi;Yasui, Hachinori;Marukawa, Hisao
    • Wind and Structures
    • /
    • 제7권3호
    • /
    • pp.203-214
    • /
    • 2004
  • This paper describes a method for developing a multi-degree-of freedom aero-elasto-plastic model of a base-isolated mid-rise building. The horizontal stiffness of isolators is modeled by several tension springs and the vertical support is performed by air pressure from a compressor. A lead damper and a steel damper are modeled by a U-shaped lead line and an aluminum line. With this model, the frequency ratio of torsional vibration to sway vibration, and plastic displacements of isolation materials can be changed easily when needed. The results of isolation material tests and free vibration tests show that this model provides the object performance. The peak displacement factors are about 4.5 regardless of wind speed in wind tunnel tests, but their gust response factor decreases with increment of wind speed.

다층 유전체위의 다중 결합선로에 대한 유한차분법(FDTD)을 이용한 해석

  • 김윤석
    • 한국군사과학기술학회지
    • /
    • 제3권1호
    • /
    • pp.155-163
    • /
    • 2000
  • A general characterization procedure based on the extraction of a 2n-port admittance matrix corresponding to n uniform coupled lines on the multi-layered substrate using the Finite-Difference Time-Domain (FDTD) technique is presented. The frequency-dependent normal mode parameters are obtained from the 2n-port admittance matrix, which in turn provides the frequency-dependent distributed inductance and capacitance matrices. To illustrate the technique, several practical coupled line structures on multi-layered substrate, including a three-line structure, have been simulated. It is shown that the FDTD based time domain characterization procedure is an excellent broadband simulation tool for the design of multiconductor coupled lines on multilayered PCBs as well as thick or thin hybrid structures.

  • PDF

AT 급전계통 해석 알고리즘 연구 (A Study Algorithm of AT Feeding Systems)

  • 추동욱;김재철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권4호
    • /
    • pp.174-179
    • /
    • 2002
  • In this paper, the modified simulation algorithms of the Auto Transformer (AT) feeding electric train system were proposed. To obtain terminal voltage of train by using equivalent circuit or the AT feeding system, the iterative method is proposed for which determine the train voltages. The train voltages are iteratively calculated from the system voltage drop and line impedance. In the carte study, the proposed method is verified from actual operation data of the Kwa-Chon line. Also it is verified that the proposed method can be extent to the multi-train simulation tool. The terminal voltage of the multi-train can be calculated by using superposition principle and it is easily applied to the proposed method. Therefore, the proposed method can be a solution for the complexity of the circuit analysis in the existing methods.

레이저 테일러드 블랭크 용접 품질 모니터링 시스템 개발 (Development of laser tailored blank weld quality monitoring system)

  • 박현성;이세헌
    • 한국레이저가공학회지
    • /
    • 제3권2호
    • /
    • pp.53-61
    • /
    • 2000
  • On the laser weld production line, a slight alteration of the welding condition produces many defects. The defects are monitored in real time, in order to prevent continuous occurrence of defects, reduce the loss of material, and guarantee good quality. The measurement system is produced by using three photo-diodes for detection of the plasma and spatter signal in CO$_2$ laser welding. For high speed CO$_2$ laser welding, laser tailored welded blanks for example, on-line weld quality monitoring system was developed by using fuzzy multi-feature pattern recognition. Weld qualities were classified optimal heat input, a little low heat input, low heat input, and focus misalignment, and final weld quality were classified good and bad.

  • PDF

An integrated system for synthesis of plant-wide control structure

  • Choi, In-Seok;Yoon, En-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1265-1270
    • /
    • 1990
  • A prototype integrated system and its theories for distributed SISO control structure synthesis of complete chemical plants is developed. The scope of this work includes control structure synthesis not only of simple units with unspecified control loops but also of the complex process at preliminary and basic design stage. Hierarchical approach and dual-decomposition strategy (that is multi-layer decomposition and multi-echelon decomposition) is applied to this system. Because automatic control structure synthesis of complex plants is a problem defined as a series of knowledge-intensive tasks within multiple spaces, the established methodology is complemented by not only techniques from knowledge-based expert systems but also shortcut and rigorous control theories. This system is used for education of control designers, process engineers, operators and students as well as for operability studying, in-line and on-line process control structure synthesis.

  • PDF

Study of Optimal Location and Compensation Rate of Thyristor-Controlled Series Capacitor Considering Multi-objective Function

  • Shin, Hee-Sang;Cho, Sung-Min;Kim, Jin-Su;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.428-435
    • /
    • 2013
  • Flexible AC Transmission System (FACTS) application study on enhancing the flexibility of AC power system has continued to make progress. A thyristor-controlled series capacitor (TCSC) is a useful FACTS device that can control the power flow by adjusting line impedances and minimize the loss of power flow and voltage drop in a transmission system by adjusting line impedances. Reduced power flow loss leads to increased loadability, low system loss, and improved stability of the power system. This study proposes the optimal location and compensation rate method for TCSCs, by considering both the power system loss and voltage drop of transmission systems. The proposed method applies a multi-objective function consisting of a minimizing function for power flow loss and voltage drop. The effectiveness of the proposed method is demonstrated using IEEE 14- and a 30-bus system.

도시가스용 퍼지 버너 개발에 관한 연구(II) (A study on the Development of Purge Burner for City Gas)

  • 이현찬;유현석;이중성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.175-179
    • /
    • 2000
  • A combustion project was completed regarding the development of a high-flow-rate purge burner in cooperation with three city gas companies(Pusan, Taegu, Samchulli). The project, started in May 1991, aimed at purging the line-packed-gas safely and quickly before getting into gas pipe working or relocation. According to the results, the purging noise is less than 80dB due to silencer screen. multi-nozzle and outlet inserted tube employed. In addition, the developed burner shows an increased work efficiency of 40-50% more as compared to the performance of conventional purge equipments. The project result is regarded as the first high-flow-rate purge burner developed within Korea. contributing to shortening purge hours, safe field work and easiness of purge site selection.

  • PDF

능동방음벽을 위한 적응필터 비교연구 (Comparative studies of adaptive filters for active noise barriers)

  • 최정일;박경원;조현기;남현도;신은우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.301-306
    • /
    • 2011
  • In this paper, active noise barriers for attenuation of road noise are proposed. multi-channel audio systems, DAQ part and high performance DSP H/W were designed. Active noise control firmware programs were implemented for multi-channel off-line/on-line estimation methods for secondary path transfer functions and FIR/IIR filter structure are used main noise control algorithms. To evaluate performance of proposed systems, the experiments were performed in an active noise barrier test bed for various noise cases.

  • PDF