• 제목/요약/키워드: Moving Joint

검색결과 240건 처리시간 0.028초

견관절 장애와 관절 가동운동(mobilization) (Joint Mobilization Techniques of the Shoulder Joint Dysfunction)

  • 김선엽
    • 대한정형도수물리치료학회지
    • /
    • 제2권1호
    • /
    • pp.39-49
    • /
    • 1996
  • The techniques of joint mobilization and traction are used to improve joint mobility or to decrease pain by restoring accessory movements to the shoulder joints and thus allowing full, nonrestriced, pain-free range of motion. In the glenohumeral joint, the humeral head would be the convex surface, while the glenoid fossa would be the concave surface. The medial end of the clavicle is concave anterioposteriorly and convex superioinferiorly, the articular surface of the sternum is reciprocally curved. The acromioclavicular joint is a plane synovial joint between a small convex facet on lateral end of the clavicle and a small concave facet on the acromion of the scapula. The relationship between the shape of articulating joint surface and the direction of gliding is defined by the convex-concave rule. If the concave joint surface is moving on a stationary convex surface, gliding occur in the same direction as the rolling motion. If the convex surface is moving on a stationary concave surface, gliding will occur in an opposite direction to rolling. Hypomobile shoulder joint are treated be using a gliding technique.

  • PDF

수직 다관절 사과수확로봇의 매니퓰레이터 개발 (I) -설계.제작- (Development of Manipulator for Vertically Moving Multi-Joint Apple Harvesting Robot(I) -Design.Manusacturing-)

  • 장익주
    • Journal of Biosystems Engineering
    • /
    • 제25권5호
    • /
    • pp.399-408
    • /
    • 2000
  • This study is final focused on developing fruit harvesting robot can distinguish fruit type and status accurately. Multi-joint robot is able to discriminate tree shape and select mature fruit by image processing. The multi-joint robot consists of (a) rotating base, (b)turning first joint-arm, (c)rotating and turning second joint-arm, (d)rotating and turning third joint-arm, (e)rotating and turning last joint and (f)picker hand. The operational ranges of the robot are: horizontal 860~2,220mm, vertical 1,440~2,260mm, 270 degrees’rotation angle, 90 or 270 degrees’turning angle. The robot weighs 330kg. The multi-joint robot was designed in high accuracy and efficiency by getting as close as the movements of human arms and waist.

  • PDF

견관절 장애와 관절 가동운동 (Joint mobilization techniques of the shoulder joint dysfunction)

  • 김선엽;두정희
    • 한국전문물리치료학회지
    • /
    • 제2권2호
    • /
    • pp.108-118
    • /
    • 1995
  • The techniques of joint mobilization and traction are used to improve joint mobility or to decrease pain by restoring accessory movements to the shoulder joints and thus allowing full, nonrestriced, pain-free range of motion. In the glenohumeral joint, the humeral head would be the convex surface, while the glenoid fossa would be the concave surface. The medial end of the clavicle is concave anterioposteriorly and convex superioinferiorly, the articular surface of the sternum is reciprocally curved. The acromioclavicular joint is a plane synovial joint between a small convex facet on lateral end of the clavicle and a small concave facet on the acromion of the scapula. The relationship between the shape of articulating joint surface and the direction of gliding is defined by the Convex-Concave Rule. If the concave joint surface is moving on a stationary convex surface, gliding occur in the same direction as the rolling motion. If the convex surface is moving on a stationary concave surface, gliding will occur in an opposite direction to rolling. Hypomobile shoulder joints are treated be using a gliding technique.

  • PDF

점성유체 속에서 움직이는 로봇팔의 동적 조작도 해석 (Dynamic Manipulability Analysis of Limb Moving in Viscous Fluid)

  • 전봉환;이지홍;이판묵
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2713-2716
    • /
    • 2003
  • This paper presents a dynamic manipulability analysis method of the limb moving in viscous fluid. The key idea of the presented method is that the boundary of joint velocity can be converted to the velocity-dependant dynamic manipulability polytope through the coriolis, centrifugal and drag terms in dynamic equation. The velocity-dependant dynamic manipulability polytope is added to the inertial and restoring force manipulability polytope to get overall manipulability polytope of the limb moving in the fluid Each of the torque and velocity bounds arc considered in the infinite norm sense in joint space, and the drag force of a limb moving in fluid viscous is modeled as a quadratic form An analysis example with proposed analysis scheme is presented to validate the method.

  • PDF

Biomechanical Analysis of Injury Factor According to the Change of Direction After Single-leg Landing

  • Kim, Jong-Bin;Park, Sang-Kyoon
    • 한국운동역학회지
    • /
    • 제26권4호
    • /
    • pp.433-441
    • /
    • 2016
  • Objective: The purpose of this study was to understand the injury mechanism and to provide quantitative data to use in prevention or posture correction training by conducting kinematic and kinetic analyses of risk factors of lower extremity joint injury depending on the change of direction at different angles after a landing motion. Method: This study included 11 men in their twenties (age: $24.6{\pm}1.7years$, height: $176.6{\pm}4.4cm$, weight: $71.3{\pm}8.0kg$) who were right-leg dominant. By using seven infrared cameras (Oqus 300, Qualisys, Sweden), one force platform (AMTI, USA), and an accelerometer (Noraxon, USA), single-leg drop landing was performed at a height of 30 cm. The joint range of motion (ROM) of the lower extremity, peak joint moment, peak joint power, peak vertical ground reaction force (GRF), and peak vertical acceleration were measured. For statistical analysis, one-way repeated-measures analysis of variance was conducted at a significance level of ${\alpha}$ <.05. Results: Ankle and knee joint ROM in the sagittal plane significantly differed, respectively (F = 3.145, p = .024; F = 14.183, p = .000), depending on the change of direction. However, no significant differences were observed in the ROM of ankle and knee joint in the transverse plane. Significant differences in peak joint moment were also observed but no statistically significant differences were found in negative joint power between the conditions. Peak vertical GRF was high in landing (LAD) and after landing, left $45^{\circ}$ cutting (LLC), with a significant difference (F = 9.363, p = .000). The peak vertical acceleration was relatively high in LAD and LLC compared with other conditions, but the difference was not significant. Conclusion: We conclude that moving in the left direction may expose athletes to greater injury risk in terms of joint kinetics than moving in the right direction. However, further investigation of joint injury mechanisms in sports would be required to confirm these findings.

관절속도를 가지는 수중로봇팔의 동적 조작도 해석 (Dynamic Manipulability Analysis of Underwater Robotic Arms with Joint Velocities)

  • 전봉환;이지홍;이판묵
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.204-209
    • /
    • 2004
  • This paper describes dynamic manipulability analysis of robotic arms moving in viscous fluid. The Manipulability is a functionality of manipulator system in a given configuration and under the limits of joint ability with respect to the tasks required to bt performed. To investigate the manipulability of underwater robotic arms, a modeling and analysis method are presented. The dynamic equation of motion of underwater manipulator is derived from the Lagrange - Euler equation considering with the hydraulic forces caused by added mass, buoyancy and hydraulic drag. The hydraulic drag term in the equation: is established as analytical form using Denavit - Hartenberg (D-H) link coordination of manipulator. Two analytical approaches based on Manipulability Ellipsoid are presented to visualize the manipulability of robotic arm moving in viscous fluid. The one is scaled ellipsoid which transforms the boundary of joint torque to acceleration boundary of end-effector by normalizing the torque in joint space while the other is shifted ellipsoid which depicts total acceleration boundary of end-effector by shifting the ellipsoid in work space. An analysis example of 2-link manipulator with proposed analysis scheme is presented to validate the method.

  • PDF

다물체 시스템이 이동하는 유연한 케이블의 동역학 해석에 관한 연구 (Dynamic Analysis of a Very Flexible Cable Carrying A Moving Multibody System)

  • 서종휘;정일호;한형석;박태원
    • 한국소음진동공학회논문집
    • /
    • 제14권2호
    • /
    • pp.150-156
    • /
    • 2004
  • In this paper, the dynamic behavior of a very flexible cable due to moving multibody system along its length is presented. The very deformable motion of a cable is presented using absolute nodal coordinate formulation, which is based on the finite element procedures and the general continuum mechanics theory to represent the elastic forces. Formulation for the sliding joint between a very flexible beam and a rigid body is derived. In order to formulate the constraint equations of this joint, a non-generalized coordinate, which has no inertia or forces associated with this coordinate, is used. The modeling of this sliding joint is very important to many mechanical applications such as the ski lifts. cable cars, and pulley systems. A multibody system moves along an elastic cable using this sliding joint. A numerical example is shownusing the developed analysis program for flexible multibody systems that include a large deformable cable.

무릎관절 재활기구에 관한 연구 (A Study on the Rehabilitation Equipment for Knee Joint)

  • 이귀형;김용진;박석현;이효성;조현아
    • 한국생산제조학회지
    • /
    • 제22권3_1spc호
    • /
    • pp.509-517
    • /
    • 2013
  • This paper presents upgraded equipment to assist a patient in rehabilitating of their knee-joint by themselves. A new automatic mechanism is suggested and developed in order to add functions for enforcing the leg muscles, which were absent in previous rehabilitation machines. Using the Pro-engineer software, we analyze the displacements and speeds of several moving points of the equipment during various planned exercises. In addition, an appropriate control panel for operation is developed. Three motors andthree motor drivers are used in a tilting part for the ankle joint, sliding guide part for the knee joint, and up-down moving part for the whole leg. Finally, various newly upgraded motions can be generated by controlling the three motors simultaneously. we show that by using this equipment, we can adjust the proper length of the equipment according to the user's height and the intensity of the rehabilitation exercise.

직각좌표 공간에서 로봇 매니퓰레이터의 직선 궤적계획에 관한 연구 (A Study on Straight Line Trajectoties of Robot Mainpulator in Cartesian Space)

  • 한상완;홍석교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.763-766
    • /
    • 1991
  • The moving of each axis in the robot manipulator can be represented with the motion of cartesian space. This paper shows the robot manipulator of the straight line trajectory planning algorithms in the cartesian space. The relation formulas between cartesian space and joint space are induced to accomplish a desired trajectory in the cartesian space and the velocity vector of sampling time in the cartesian space is transformed into the velocity vector of joint by the interpolation method. The error of trajectory in moving is removed by obtaining the real position for the present joint position and the desired distance is made by comparing the real position and the next position. Through the simple tests for suggested algorithms are confirmed the validity of algorithms.

  • PDF