• 제목/요약/키워드: Moving Body

검색결과 628건 처리시간 0.026초

심초음파도내에서의 심장 판막 운동 추적을 위한 동영상 처리 기술에 대한 기초 연구 (I) (A study on the development of an image processing technique for tracing the movement of heart valves in echocardiograms (I))

  • 육인수;김재익;최홍호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.88-91
    • /
    • 1997
  • One of the most significant feature of diagnostic ultrasonic instrument is to display information on the soft tissues in the body in real time. In this paper we carried out basic study on the digital moving image processing for tracing the movement of heart valves in echocardiograms. Digital moving image file was made from analog echocardiograms and it was remade as 256 gray-level images on each frame. The ROI(Region of interest) was placed on a heart valve region to process images efficiently. Images were processed by the use of image enhancement filters and morphology filters. The result shows that the processed images were more enhanced than original images. When a moving image is reconstructed by using these enhanced images, we can trace the movement of heart valves more easily. In this study we proposed the availability of the moving image reconstruction using enhancement images.

  • PDF

Moving reactor model for the MULTID components of the system thermal-hydraulic analysis code MARS-KS

  • Hyungjoo Seo;Moon Hee Choi;Sang Wook Park;Geon Woo Kim;Hyoung Kyu Cho;Bub Dong Chung
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4373-4391
    • /
    • 2022
  • Marine reactor systems experience platform movement, and therefore, the system thermal-hydraulic analysis code needs to reflect the motion effect on the fluid to evaluate reactor safety. A moving reactor model for MARS-KS was developed to simulate the hydrodynamic phenomena in the reactor under motion conditions; however, its applicability does not cover the MULTID component used in multidimensional flow analyses. In this study, a moving reactor model is implemented for the MULTID component to address the importance of multidimensional flow effects under dynamic motion. The concept of the volume connection is generalized to facilitate the handling of the junction of MULTID. Further, the accuracy in calculating the pressure head between volumes is enhanced to precisely evaluate the additional body force. Finally, the Coriolis force is modeled in the momentum equations in an acceleration form. The improvements are verified with conceptual problems; the modified model shows good agreement with the analytical solutions and the computational fluid dynamic (CFD) simulation results. Moreover, a simplified gravity-driven injection is simulated, and the model is validated against a ship flooding experiment. Throughout the verifications and validations, the model showed that the modification was well implemented to determine the capability of multidimensional flow analysis under ocean conditions.

WBAN Off-Body 채널에서 안테나 편파의 영향 분석 (Experimental Study on the Effect of Antenna Polarization in WBAN Off-Body Channel)

  • 전재성;안병직;김선우;최재훈
    • 한국전자파학회논문지
    • /
    • 제24권2호
    • /
    • pp.144-151
    • /
    • 2013
  • 본 논문에서는 무선 인체 통신 중 off-body 채널에서 안테나 편파의 변화에 대한 영향을 알아보기 위한 실험을 수행하였다. 실험은 두 수신 안테나의 편파 조합에 따라 총 4가지로 나누었으며, Line-of-Sight(LOS)와 Non-LOS(NLOS)에 따른 영향도 조사하였다. 그리고 인체의 움직임으로 인하여 생기는 안테나 편파의 변화가 신호에 어떠한 영향을 미치는지 알아보기 위해, 인체를 정지한 상태와 움직이는 상태로 나누어 신호 세기를 측정하여 비교하였다. 본 논문의 결과를 통해 수신 안테나의 편파 및 두 수신 안테나의 편파 조합에 따른 성능을 확인하였다.

Phantom을 이용한 사이버나이프 $Synchrony^{TM}$ 호흡 추적장치의 정확성 평가 (Accuracy Evaluation of CyberKnife $Synchrony^{TM}$ Respiratory Tracking System Using Phantom)

  • 김가중;배석환;임창선;김종일
    • Journal of Radiation Protection and Research
    • /
    • 제34권3호
    • /
    • pp.137-143
    • /
    • 2009
  • 본 연구는 호흡에 따라 움직임이 큰 흉부나 복부 장기의 방사선 수술에 적용되는 사이버나이프 $Synchrony^{TM}$ 호흡 추적장치의 정확성을 평가하였다. $Synchrony^{TM}$ 호흡 추적장치의 정확성 평가를 위해 금침이 삽입된 움직임 Phantom을 이용하였고, Phantom은 아크릴 볼이 들어 있는 정육면체에 Radiochromic 필름을 삽입하여 가상의 치료용적인 아크릴 볼에 21 Gy, 70% 등선량곡선으로 처방하였다. 고정된 Phantom의 금침추적방법과 움직임 Phantom의 $Synchrony^{TM}$ 호흡추적 방법으로 나누어 각각 5회 측정한 정확성 평가는 고정된 Phantom 추적 시 총 에러는 $0.0195{\sim}0.652mm$, 총 에러 평균은 0.3926 mm로 나타났으며, 움직임 Phantom을 이용한 $Synchrony^{TM}$ 호흡 추적 방법의 결과로 총 에러는 $0.4405{\sim}0.7665mm$, 총 에러 평균은 0.5673 mm로 나타나 두 방법에 유의한 차이가 없었다. 본 연구를 통해 사이버나이프 $Synchrony^{TM}$ 호흡 추적 장치의 정확성을 평가하였으며 체부의 방사선 수술 적용 시 그 유용성을 확인할수 있었다.

Numerical simulations of two-dimensional floating breakwaters in regular waves using fixed cartesian grid

  • Jeong, Kwang-Leol;Lee, Young-Gill
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권2호
    • /
    • pp.206-218
    • /
    • 2014
  • The wave attenuation by floating breakwaters in high amplitude waves, which can lead to wave overtopping and breaking, is examined by numerical simulations. The governing equations, the Navier-Stokes equations and the continuity equation, are calculated in a fixed Cartesian grid system. The body boundaries are defined by the line segment connecting the points where the grid line and body surface meet. No-slip and divergence free conditions are satisfied at the body boundary cell. The nonlinear waves near the moving body is defined using the modified marker-density method. To verify the present numerical method, vortex induced vibration on an elastically mounted cylinder and free roll decay are numerically simulated and the results are compared with those reported in the literature. Using the present numerical method, the wave attenuations by three kinds of floating breakwaters are simulated numerically in a regular wave to compare the performance.

지점운동을 받는 정정보의 동해석을 위한 동지점 유한요소 개발 (Moving Support Elements for Dynamic Finite Element Analysis of Statically Determinate Beams Subjected to Support Motions)

  • 김용우;정명조
    • 대한기계학회논문집A
    • /
    • 제37권4호
    • /
    • pp.555-567
    • /
    • 2013
  • 지점운동을 받는 베르누이-오일러 보의 동적 유한요소해석을 위하여, 준정적 분해법을 사용하여 유한요소 정식화 및 지점운동 묘사를 위한 보요소를 개발하였다. 이 보요소들은 전통적인 2 절점 Hermitian 보 요소로서 기존의 모델링 방법을 그대로 따르면서 한 쪽 절점이 운동하는 지점과 일치하는 경우 해당 요소만을 본 연구에서 제안하는 요소로 대체하여 사용할 수 있도록 수식화하였다. 이 요소의 유용성과 정확성을 보이기 위해 지점운동을 받는 정정보들에 대해 수치실험을 실시하고 그 결과들을 이론해와 비교함으로써 사용이 간편함과 동시에 정확도가 매우 높다는 사실을 보였다.

The Effects of Ramp Gradients and Pushing-Pulling Techniques on Lumbar Spinal Load in Healthy Workers

  • Pinupong, Chalearmpong;Jalayondeja, Wattana;Mekhora, Keerin;Bhuanantanondh, Petcharatana;Jalayondeja, Chutima
    • Safety and Health at Work
    • /
    • 제11권3호
    • /
    • pp.307-313
    • /
    • 2020
  • Background: Many tasks in industrial and health care setting are involved with pushing and pulling tasks up or down on a ramp. An efficient method of moving cart which reduces the risk of low back pain should be concerned. This study aimed to investigate the effects of handling types (HTs) and slope on lumbar spinal load during moving a cart on a ramp. We conducted a 2 × 2 × 4 factorial design with three main factors: 2 HTs, 2 handling directions of moving a cart and 4 degrees of ramp slope. Methods: Thirty healthy male workers performed 14 tasks consist of moving a cart up and down on the ramp of 0°, 10°, 15°, and 20° degrees with pushing and pulling methods. Joint angles from a 3D motion capture system combined with subject height, body weight, and hand forces were used to calculate the spinal load by the 3DSSPP program. Results: Our results showed significant effect of HT, handling directions and slope on compression and shear force of the lumbar spine (p < 0.001). When the ramp gradient increased, the L4/5 compression forces increased in both pushing and pulling (p < 0.001) Shear forces increased in pulling and decreased in pushing in all tasks. At high slopes, pulling generated more compression and shear forces than that of pushing (p < 0.01). Conclusion: Using the appropriate technique of moving a cart on the ramp can reduce the risk of high spinal load, and the pushing is therefore recommended for moving a cart up/down on ramp gradients.

Geant 4 시뮬레이션 코드를 이용한 호흡 동조 방사선치료의 유용성 비교 (Comparison of Practical Usefulness of Respirational Radiation Treatment Using Geant 4 Simulation Code)

  • 장은성;이효영
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.637-643
    • /
    • 2019
  • 인체 내부의 움직임을 확인하기 위해서 CT에서 얻은 DICOM 파일과 Geant4 코드를 이용하여 폐암환자를 모사하였다. 자체 제작한 Moving Phantom에 가상의 종양을 만들어 종양의 움직임이 호기와 흡기에 위치했을 때 종양의 움직임을 측정하는 방법과 이것을 적용하여 Moving Phantom을 통한 치료계획시의 선량분포와 호흡동조 폐암환자 PTV내의 종양의 정확도를 확인하고자 한다. 움직이는 영역이 3cm 이상이라도 40~70 % 구간에서 호흡 동조 방사선치료를 시행 할 경우 97% 이상 효과적임을 확인하였다. 움직이는 표적에 호흡 연동 방사선치료를 적용한 선량 분포인데 이는 구동 팬텀 내 필름으로 측정한 것으로 90%가 포함되는 선량분포의 오차범위 3mm이내에 분포됨을 알 수 있었다. 실제 환자 호흡곡선의 경우 호기 상태의 시간이 사인곡선에 비하여 길기 때문에 치료시간이 이보다 짧을 수 있음을 확인하였다.