• Title/Summary/Keyword: Mounting method

Search Result 279, Processing Time 0.026 seconds

3D Inspection of Printed Circuit Boards (PCB의 3차원 검사)

  • 조홍주;박현우;이준재
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2375-2378
    • /
    • 2003
  • In manufacture of printed circuit boards, one important issue is precisely to measure the three-dimensional shape of the solder paste silk-screened prior to direct surface mounting of chips. This paper presents the 3D shape reconstruction of solder paste using the optical triangulation method based on structured light or slit beam and the measurement algorithm for height, volume. area, and coplanarity on component pads from the 3D range image. Futhermore, statistical process control function is incorporated for process capability analysis.

  • PDF

Vibration Characteristics of a Compound Mounting System on an Elastic Floor (탄성바닥에 지지된 합성방진계의 진동특성)

  • 김찬묵;윤수언
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.151-156
    • /
    • 1993
  • 본 논문에서는 탄성바닥 위에서의 세개의 질량과 두개의 방지재로 구성된 지지계에 의한 진동절연의 이론적 고찰과 실험에 의한 검증을 하였다. 효과 적인 진동절연은 본 논문에서 기본적으로 관심을 가지는 탄성바닥에서의 진 동전달률을 감소시키는 것이며, 단순한 수학적 형태로 표현되는 진동전달률 공식은 영향계수법(Receptance Method)을 이용하여 유도된다.

  • PDF

A New Material for Rapid and Easy Method of Plant Surface Imprinting

  • Bhat, R.B.;Etejere, E.O.
    • Journal of Plant Biology
    • /
    • v.28 no.4
    • /
    • pp.329-332
    • /
    • 1985
  • A simple new device for obtaining very clear epidermal imprints for light microscopic studies is discussed. This new device is developed from“Britfix”(polystyrene cement) which is non-toxic to the plant organs. It involves direct application of the material on the desired surface of the plant organ to obtain thin, transparent replica. From the present investigation“Britfix”is found to be useful for the study of epidermal anatomy, morphology and physiology. Epidermal imprints can be mounted on the microscope slide without a mounting medium. Permanent slide of these imprints can be kept for any desired period without any deterioration of the replica.

  • PDF

Structureborne Noise Transfer Analysis Using Pole Parameter Method for Resiliently Mounted Equipment (절점 해석 기법을 이용한 탄성지지 장비 시스템의 고체음 전달 해석)

  • Choi, Tae-Muk;Kim, Tae-Suk;Cho, Dae-Seung;Chung, Jung-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.398-402
    • /
    • 2005
  • Structureborne noise induced by shipboard equipment is one of the most significant noise source of ships and can be effectively reduced by resiliently mounting them. In this paper, the pole parameter method is investigated for estimating the structureborne noise reduction of resiliently mounted equipment. In addition, we suggest how to evaluate pole parameters from dimensional and material information of each component consisting of resiliently mounted equipment. To validate and discuss the proposed method numerical analysis for single and double resiliently mounted equipment systems using both pole parameter method and FEM have been done.

  • PDF

Korea Industrial Standardization Draft for ISO 354 (ISO 354 (잔향실법 흡음률 측정방법)의 KS 규격화)

  • Jung, Sung-Soo;Kook, Chan;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.857-860
    • /
    • 2003
  • We introduced the basic direction of revision for KS F 2805 (method for measurement of sound absorption coefficient in a reverberation room). It is fundamentally equal to ISO 354 (measurement of sound absorption in a reverberation room) which was state of ISO/FDIS 354. Two main points were strongly reviewed. First, the sound absorption coefficient values for Type J test specimen mounting was investigated. Next, the reverberation time difference between the conventional method and new additional one, impulse response method were compared.

  • PDF

Restoration of 'Arhat' of Koryo Dynasty -Collection of the National Museum of Korea- ('나한도(羅漢圖)'의 보존수복(保存修復) -국립중앙박물관(國立中央博物館) 소장(所藏) 고려불화(高麗佛畵)-)

  • Park, Chi-sun
    • Conservation Science in Museum
    • /
    • v.2
    • /
    • pp.41-49
    • /
    • 2000
  • The most important aspect in preserving ancient paintings is to return the painting to the original state and conserve it in the original state. One traditional recovering method is the use of frame, for which scientific analysis such as X-rays, infrared and microscope are used and materials are carefully selected. Arhat, a Buddhist painting of Koryo Dynasty, one of the Korean National Museum collections has lost its original shape. With conservation treatment, the cause was found, that is to change frame scroll method to mounting method. In the main body, pre-analysis and conservation method of Arhat will be introduced.

Development of Pulse Analysis System Based on Convenience and Compactness (사용 편의성과 소형화 기반의 맥파 측정장치 개발)

  • Cho, JungHee;Bae, JangHan;Kim, YoungMin;Jun, MinHo;Yang, TaeHeon;Jeon, YoungJu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.168-174
    • /
    • 2017
  • To improve and downsize the KIOM-Pulse Analysis System(KIOM-PAS), which has been traditionally used in clinical trials, a miniaturized PAS(M-PAS) with a pneumatic pump has been developed. M-PAS is composed of a measurement module and an arm-mounting module, on which an arm can be placed. The measurement module is equipped with a pressing component and sensor, which is a wearable wristband. The arm-mounting module includes a pneumatic motor, data acquisition board and valves. In addition, the measurement module is divided into a fixing module of band type for attachment to a pulsation site and a sensing module, which includes a sensor and a tube. The fixing module and sensing module are constructed independently, and the detachable fastening method improves the posture convenience of the subject during measurement. M-PAS has been reduced to 1/6 the size of KIOM-PAS, and the measurement time is shortened by 22%. Using a simulator, the difference between the waveforms measured by the two devices exhibited a high degree of similarity of within 3.65%. M-PAS represents improvements in size and convenience compared with KIOM-PAS, and it is expected to be widely used in clinics in the future because it improves the attachment method of the fixing module.

Reliability life evaluation of gear driving system for the intermediate shaft (중간축을 고려한 기어구동장치의 신뢰수명 평가)

  • 김하수
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.4
    • /
    • pp.147-153
    • /
    • 2000
  • This paper presents a design method using CAE(Computer Aided Engineering ) with the consideration of reliability for optimal gear driving system. This method considered a configuration of the intermediate shaft. There are four mounting types, such as double straddle, double overhung, output gear overhung, and input ger overhung in the intermediate shaft. The reliability and life analysis are based on the two-parameter Weigbull distribution lives of the gears and bearing . The validity and feasibility of the proposed method are verified by the application to transmission of a industry machine.

  • PDF

Dynamic Analysis of Base-Isolated Rectangular Liquid Storage Structures (기초격리된 직사각형 유체 저장 구조물의 동적 해석)

  • Park, Jang-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.109-116
    • /
    • 2004
  • The dynamic behavior of the rectangular liquid storage structure is known to be greatly influenced by fluid-structure interaction. By mounting the liquid storage structure on the properly designed base isolators, dynamic response of the superstructure can be reduced. However, base isolators inevitably incur large displacement of the structure to the ground ·ind may give adverse effects on the sloshing height. This paper presents the analysis method for fluid-structure-isolator interaction in base-isolated rectangular liquid storage structures. In the method, the irrotational motion of invicid and incompressible ideal fluid is expressed by analytic solutions and the superstructure and isolators are properly modeled by finite element and bilinear model. Free surface sloshing motion, hydrodynamic pressure acting on the wall and structural response are obtained by the presented method.

Analysis of Printed Circuit Boards Based on Electromagnetic Topology (Electromagnetic Topology(EMT) 기법을 이용한 Printed Circuit Boards(PCBs) 기판 해석)

  • Hwang Se-Hoon;Lee Jung-Yub;Jung Hyun-Hyo;Park Yoon-Mi
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.170-174
    • /
    • 2006
  • In this paper electromagnetic topology (EMT) is used to analyze the lumped components on printed circuit boards (PCBs). It is difficult to obtain desirable results about the electromagnetic coupling problems by using a numerical or an experimental method on complex systems. The EMT can be considered as a helpful method to the analysis of electromagnetic interference / electromagnetic compatibility (EMI/EMC) problems in the complex system. To verify the validity of this method, three types of the PCBs mounting a simple circuit are fabricated and experimented.

  • PDF