• 제목/요약/키워드: Motor input voltage

검색결과 258건 처리시간 0.031초

브로워용 전동기 인버터의 순시추종 PWM 제어 (Instantaneous Following PWM Control of Inverter for Blower Motor)

  • 라병훈;권순걸;이현우;전중함;김광태
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.275-278
    • /
    • 2003
  • Conventional vector control inverter is usually used for blower of air-accord equipment. In this paper, it is proposed that inverter is controlled by instantaneous following PWM controller. This controller compensate and follow for output voltage of inverter within one switching cycle as an error that compared output voltage of rectifier included much ripples with reference voltage of sine wave. It has not speedy response like vector controller, but the circuit is very simple as using analog integer. And it has advantages that develop input power factor, built small-capacity and low-cost because huge capacitor of voltage type inverter removed.

  • PDF

IPMSM의 선간단락고장에 따른 새로운 d -q 등가회로 (Simplified d -q Equivalent Circuit of IPMSM Considering Inter-Turn Fault State)

  • 강봉구;허진
    • 전기학회논문지
    • /
    • 제65권8호
    • /
    • pp.1355-1361
    • /
    • 2016
  • The inter-turn fault (ITF) causes the negative sequence components in the d -q voltage equation due to an increase in the unbalance of three-phase input currents. For this reason, d -q voltage equation become complicate as the voltage equation is classified into positive and negative components. In this study, we propose a simplified d -q equivalent circuit of an interior permanent magnet synchronous motor under ITF state. First, we proposed modeling method for d -q current based on the finite element method simulation results. Then, we developed the simplified d -q equivalent circuit by applying the proposed d -q current modeling.

슬라이딩 모드 제어를 이용한 단상 유도전동기의 저 전류 기동 시뮬레이션 (The Low Current Starting Simulation of a Single Phase Induction Motor Using Sliding Mode Control)

  • 김효기;이병하
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.44-53
    • /
    • 2007
  • 단상유도전동기의 기동전류를 줄이기 위하여 슬라이딩모드 제어기가 적용된다. 단상유도전동기의 기동전류가 정격치 이하로 유지되도록 슬라이딩모드 제어기의 스위칭 기능을 조절함으로써 전동기 입력전압이 제어되며 또한 속도도 제어된다. 슬라이딩 모드 제어기의 스위칭은 속도 오차 신호와 속도 변화량에 대하여 적절이 수행된다. 단상 유도 전동기의 기동특성이 슬라이딩 제어기를 사용하여 크게 향상될 수 있음을 보여 준다.

Optimal Design of a Damped Input Filter Based on a Genetic Algorithm for an Electrolytic Capacitor-less Converter

  • Dehkordi, Behzad Mirzaeian;Yoo, Anno;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.418-429
    • /
    • 2009
  • In this paper an optimal damped input filter is designed based on a Genetic Algorithm (GA) for an electrolytic capacitor-less AC-AC converter. Sufficient passive damping and minimum losses in passive damping elements, minimization of the filter output impedance at the filter cut-off frequency, minimization of the DC-link voltage and input current fluctuations, and minimization of the filter costs are the main objectives in the multi-objective optimization of the input filter. The proposed filter has been validated experimentally using an induction motor drive system employing an electrolytic capacitor-less AC-AC converter.

이산 전류 제어를 위한 공진형 인버터 (A Simple Resonant Link Inverter for a Discrete-Time Current Control)

  • 오인환;정영석;주형길;윤명중
    • 전력전자학회논문지
    • /
    • 제3권1호
    • /
    • pp.36-45
    • /
    • 1998
  • 공진형 인버터의 직류 링크단의 전압 상승을 직류 공급 전압 이내로 제한하고, 공진형 인덕터의 전류 내량을 줄이기 위한 간단한 전압 억제형 공진형 인버터를 제안하였다. 이 전압 인버터를 영구 자석형 동기 전동기(PMSM)에 적용하여 이산 펄프 제어 방법중의 하나인 예측형 전류 제어 방법에 의해 실험과 시뮬레이션을 통하여 제안된 인버터의 동작을 보이고, 그 결과를 CRDM(Current Regulated Delta Modulation)방법에 의한 결과와 비교하였다.

Performance test of 100 W linear compressor

  • Ko, J.;Koh, D.Y.;Park, S.J.;Kim, H.B.;Hong, Y.J.;Yeom, H.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.35-39
    • /
    • 2013
  • In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.

출력커패시터 내압 저감이 가능한 승압 컨버터 구조 (Circuit configuration of step-up converter with reduced working voltage of output capacitor)

  • 김선필;박성준;강필순
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.630-637
    • /
    • 2018
  • 모터제어장치(MCU)는 높은 전압을 공급하기 위해 인버터 앞 단에 승압용 컨버터를 사용한다. 승압 컨버터는 높은 출력전압을 생성하기 때문에 내압이 높은 출력 커패시터가 필요하여 커패시터의 비용이 증가하게 된다. 이를 해결하기 위해 출력 커패시터의 작동 전압을 낮출 수 있는 승압 컨버터 구조를 제시한다. 제안된 컨버터의 기본 특성은 기존의 부스트 컨버터와 유사하며, 출력 커패시터와 입력 배터리를 직렬로 연결하는 출력 단자의 구조적 차이가 있다. 이러한 출력단 회로 구조에 의해 출력 커패시터의 동작 전압은 기존 승압 컨버터 보다 낮아진다. 이론적 분석, 시뮬레이션, 실험을 통해 기존 부스트 컨버터와 비교하고 타당성과 성능을 검증한다.

Sensorless Fuzzy Logic Soft Start of Induction Motor With Load Detection

  • Arehpanahi, Mehdi;Monfared, Jafar Mili;Abbaszadeh, Karim
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2378-2381
    • /
    • 2003
  • In recent years, fuzzy logic has received greater emphasis in the field of power electronics and motion control by virtue of its adaptive capability. A new fuzzy logic based soft-start scheme for induction motor drives close to load detection has been discussed here using microcontroller based thyristorised voltage controller. Rule based soft-start algorithm is fully realised through a software approach only. The soft-start strategy is based on the change of input impedance during starting period. The prototype has been tested under various loading conditions and found to be reliable.

  • PDF

유도전동기 드라이브를 위한 FLC-MPPT 태양광 발전시스템 (FLC-MPPT Photovoltaic System for Induction Motor Drive)

  • 최정식;고재섭;정병진;김도연;박기태;최정훈;정동화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.301-305
    • /
    • 2007
  • This paper is proposed by fuzzy-based MPPT control of photovoltaic to drive induction motor. Design and prototype implement of a fuzzy logic(FL) controller for maxim]m power extraction from a stand-alon photovoltaic Is proposed in this paper. Error and the change of error between maximum power and real power are used by input of fuzzy controller. Moreover, it output changing of voltage from control constant. The validity of this paper is proved by comparing maximum power point tracking and performance of motor drive through comparison fuzzy and PI of tradition method.

  • PDF

공작기계 주축용 스핀들 전동기 구동에 관한 연구 (A Study on the Spindle Motor Drive for the Spindle of Machining Center)

  • 한영성;안성찬;송종환;이학성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2110-2112
    • /
    • 1997
  • The induction motor drive for the spindle of machining center is required to do not only a constant torque operation in low speed region(below base rpm), but also a constant power operation in high speed region(beyond base rpm). Also, control voltage shortage due to high speed operation must be overcome. The vector controlled inverter system with input 3 phase pwm converter is designed for that kind of condition. We experimented the performance of the inverter system with spindle motor made by Hyosung industries co.

  • PDF