• Title/Summary/Keyword: Motor drive inverter

Search Result 538, Processing Time 0.022 seconds

SiC Motor Drive for Elevator System (엘리베이터 시스템을 위한 SiC 권상기 드라이브)

  • Gwon, Jin-Su;Moon, Seok-Hwan;Kim, Ju-Chan;Lee, Joon-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.147-152
    • /
    • 2019
  • With the recent emphasis on the importance of energy conservation, studies on high-efficiency elevator systems are being continuously conducted. Therefore, pulse width modulation converters are commonly used in traction drives on elevator systems. Wide bandgap devices have been increasingly commercialized, and their application to power conversion systems, such as renewable and energy storage system, has been gradually increasing. In this study, a SiC inverter for an elevator traction drive is investigated. In particular, an inverter is designed to minimize stray and parasitic inductance. Input and output filters are designed by considering switching frequency. The designed SiC inverter reduces volume by approximately 32% compared with that of a Si inverter, and power converter efficiency is over 98.8%.

Power Regenerating Drive of a Induction Motor by Field Acceleration Method (자계가속법에 의한 유도 전동기의 전력회생 구동)

  • Hong, Soon-Ill;Hong, Jeng-Pyo;Jung, Seoung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.417-424
    • /
    • 2007
  • This paper presents a solution that an analytical model for an induction motor and the formula of regenerative power and instantaneous torque are derived. based on the spiral vector. The torque is controlled linearly through variations of the slip angular velocity, based on the field acceleration method (FAM). And also PWM inverter fed induction motor drives is schemed to be easily a regenerative drive. The voltage source inverter fed induction motor drives that regenerative power occurs with back current type is presented, to easily controlled the feedback power and to proper the adaption of energy shaving drives. The experimental tests verify the performance of the FAM, proving that food behavior of the drive is achieved in the transient and steady state operating condition, and are discussed to save the power that regenerative power is measured at the operating acceleration or deceleration of servo system.

A Diagnosis Scheme of Switching Devices under Open Fault in Inverter-Fed Interior Permanent Magnet Synchronous Motor Drive (매입형 영구자석 동기전동기 구동용 인버터 스위칭 소자의 개방 고장 진단)

  • Choi, Dong-Uk;Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.3
    • /
    • pp.61-68
    • /
    • 2012
  • This paper deals with a fault diagnosis algorithm for open faults in the switching devices of PWM inverter-fed IPMSM (Interior Permanent Magnet Synchronous Motor) drive. The proposed diagnostic algorithm is realized in the controller using the informations of three-phase currents or reference line-to-line voltages, without requiring additional equipments for fault detection. Under switch open fault conditions, the conventional dq model used to control an AC motor cannot directly be applied for the analysis of drive system, since three-phase balanced condition does not hold. To overcome this limitation, a fault model based on the line-to-line voltages is employed for the simulation studies. For comparative performance evaluation through the experiments, the entire control system is implemented using digital signal processor (DSP) TMS320F28335. Simulations and experimental results are presented to verify the validity of the proposed diagnosis algorithm.

High Precison Bearing Fault Detect System of Inverter Driven System Using Oversampled Current Signals (오버샘플된 전류신호를 사용한 인버터 구동형 전동기의 베어링 고장검출 시스템)

  • Kim, Nam-Hun;Kim, Min-Heui;Choi, Chang-Ho;Lee, Sang-Hoon;Choi, Keyng-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.506-508
    • /
    • 2007
  • In this paper, the induction motor bearing fault diagnosis system using current signals which are measured by over-sampling method is presented. In the case of inverter fed motor drive unlike line-driven motor drive, that make a lot of noise which can cause a wrong fault signals because of PWM(pulse width modulation) voltage. So, the current signals for fault diagnosis need very precise and high resolution information, which means this system demand additional hardware such as low pass filter, high resolution ADC system and so on to use fault diagnosis system. Therefore, the proposed over-sampling method is expected to contribute to low cost fault diagnosis system even though previous inverter fed motor drive without any additional hardware. In order to confirm the presented algorithms, various experiments for bearing faults are tested and the line current spectrum of each faulty situation using park transformation is compared with a FFT results.

  • PDF

The Comparative Analysis of 2-Phase Inverter Topologies for 2-Phase Induction Motor (2상 유도전동기 구동을 위한 2상 인버터 토폴로지의 비교 분석)

  • Kim, Dong-Ki;Yoon, Duck-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1013-1018
    • /
    • 2016
  • In this paper, three kinds of the inverter topologies for the variable speed drive of 2-phase induction motor are compared and analyzed. The 2-phase inverters are classified into 2-leg, 3-leg, and 4-leg types depending on the number of power switching devices. And they use the output voltage vectors of the different forms according to the inverter topologies. Based on the comparative analyzed results, the effective values of output voltage have been defined by the linear modulation range. Therefore, the motor design guideline is proposed in order to decide a rated voltage of 2-phase induction motor according to the inverter topologies. Also, the computer simulations are carried out to verify the output voltage and current characteristics of each inverter topology.

Induction Motor Drive Using a Line Commutated Inverter with a Forced-Commutated Circuit (장제전류회로를 갖는 타려식 인버터를 이용한 유도적 성질)

  • 정연택;심재명
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.6
    • /
    • pp.588-599
    • /
    • 1992
  • This paper describes the variable speed drive of an induction motor by the line commutated inverter, which is operated in the forced commutation mode from start-up to operating point of load commutation. A novel forced-commutation circuit is proposed in this paper. The selection range of leading condenser to decide load commutation starting point is simulated by the sampling data of a general purpose IM and a high speed IM. The experiment to drive IM by a line commutated inverter with the proposed forced commutated circuits is performed. There was no problem in driving IM from standstill to starting point of load commutation by a line commutated inverter with forced commutation.

An examples of a 6-inch GTO inverter drive system applied for rougher mills

  • Kawasaki, Muneo;Okayama, Hideo;Koyama, Masato;Mitsuhashi, Masamichi;Masuda, Hiroyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.25-28
    • /
    • 1996
  • Recently, AC variable-speed motors are used for many steel rolling mill drive systems, because of their low maintenance and enhanced control performance. We have been applied GTO inverters for these AC motor drive systems since 1993. We have developed world largest 6-inch diameter GTO and large capacity 3-level GTO inverter up to 20000(kVA). As an example, in this paper, we describe the main circuit, system arrangement and control features of the 6-inches GTO inverters to drive rougher mills for hot strip mill of Pohang Iron & Steel Co., Ltd. The motor capacity is 6000(kW), and it's overload is 250(%).

  • PDF

DC-Link Voltage Unbalancing Compensation of Four-Switch Inverter for Three-Phase BLDC Motor Drive (3상 BLDC 전동기 구동을 위한 4-스위치 인버터의 DC-Link 전압 불평형 보상)

  • Park, Sang-Hoon;Yoon, Yong-Ho;Lee, Byoung-Kuk;Lee, Su-Won;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.391-396
    • /
    • 2009
  • In this paper, a control algorithm for DC-Link voltage unbalancing compensation of a four-switch inverter for a three-phase BLDC motor drive is proposed. Compared with a conventional six-switch inverter, the split source of the four-switch inverter can be obtained by splitting DC-link capacitor into two capacitors to drive the three phase BLDC motor. The voltages across each of two capacitors are not always equal in steady state because of the unbalance in the impedance of the DC-link capacitors $C_1$ and $C_2$ or the variable current flowed into the capacitor's neutral point in motor control. Despite the unbalance, if the BLDC motor may be run for a long time the voltage across one of the capacitors is more increased. So the unbalance in the capacitors voltages will be accelerated. As a result, The current ripple and torque ripple is increased due to the fluctuation of input current which flows into 3-phase BLDC motor. According to that, the vibration of motor will be increased and the whole system will be instable. This paper presents a control algorithm for DC-Link voltage unbalancing compensation. The sampling from the voltages across each of two capacitors is used to perform the voltage control of DC-Link by using the feedforward controller.

Drive Circuit of 4-Level Inverter for 42V Power System

  • Park, Yong-Won;Sul, Seung-Ki
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.3
    • /
    • pp.112-118
    • /
    • 2001
  • In the near future, the voltage of power system for passenger vehicle will be changed to 42V from existing 14V./ Because of increasing power and voltage ratings used in the vehicle the motor drive system has high switching dv/dt and it generates electromagnetic interference (EMI) To solve these problems multi-level inverter system may be used The feature of multi-level inverter is the output voltage to be synthesized from several levels of voltage Because of this feature high switching dv/dt and EMI can be reduced in the multi-level inverter system But as the number of level is increased manufacturing cost is getting expensive and system size is getting large. Because of these disadvantages the application of multi-level inverter has been restricted only to high power drives. The method to reduce manufacturing cost and system size is to integrate circuit of multi-level inverter into a few chips But isolated power supply and signal isolation circuit using transformer or opto-coupler for drive circuit are obstacles to implement the integrated circuit (IC) In this paper a drive circuit of 4-level inverter suitable for integration to hybrid or one chip is proposed In the proposed drive circuit DC link voltage is used directly as the power source of each gate drive circuit NPN transistors and PNP transistors are used to isolate to transfer the control signals. So the proposed drive circuit needs no transformers and opto-couplers for electrical isolation of drive circuit and is constructed only using components to be implemented on a silicon wafer With th e proposed drive circuit 4- level inverter system will be possible to be implemented through integrated circuit technology Using the proposed drive circuit 4- level inverter system is constructed and the validity and characteristics of the proposed drive circuit are proved through the experiments.

Open Fault Characteristic of Inverter for Permanent Magnet Synchronous Motor Drive (영구자석 동기전동기 구동을 위한 인버터의 개방고장 특성)

  • Kim, Kyeong-Hwa;Choi, Dong-Uk;Gu, Bon-Gwan;Jung, In-Soung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.76-79
    • /
    • 2009
  • This paper presents analyses and performance evaluations of a PWM inverter for a permanent magnet synchronous motor drive under open fault conditions caused by the open fault in one switching device or isolation between the inverter and motor terminal. A fault model for a PWM inverter is derived and experiment is carried out by using DSP TMS320F28335 to provide the basis of fault diagnosis for such a case.

  • PDF