• Title/Summary/Keyword: Motor Unit

Search Result 583, Processing Time 0.029 seconds

A Study on the Application Design for Wireless Communication Control and Development of Stepping-motor Microcontroller Unit capable of Wireless Communication Control (무선통신 제어 가능한 스테핑모터 마이크로컨트롤러유닛 개발과 무선통신 제어를 위한 어플리케이션 디자인에 관한 연구)

  • Kang, Hee-Ra
    • Journal of Digital Convergence
    • /
    • v.17 no.12
    • /
    • pp.503-508
    • /
    • 2019
  • In recent years, among the IoT products that are used in various ways in everyday life, motorized products are increasing. This study aims to develop a microcontroller unit that can easily control multiple motors and develop an application that makes use of this microcontroller unit. The basis of the hardware developed by the research was the Arduino board, and to it, the Bluetooth module, Zigbee module, and a motor driver were connected. To control the device, an application was designed. The final microcontroller unit and its application may be applied to electric curtains, electric blinds, robots, and other various IoT products. Further research will lead to hardware development that can control various types of motors other than stepping motors.

Heat Transfer Analysis of Bearing Unit in Submersible Motor Pump (수중 모터펌프 베어링 유닛 열전달 해석)

  • Yun, Jeong-Eui;Byun, Hyung-Kyun
    • Tribology and Lubricants
    • /
    • v.27 no.4
    • /
    • pp.198-203
    • /
    • 2011
  • The purpose of this paper is to find a proper cooling system of bearing unit in the submersible motor pump to extend a life time. To do this, heat transfer analysis of the submersible motor pump were performed using commercial CFD code ANSYS. In order to obtain the resonable heat transfer simulation results, we first set up mathematical model of heat source in the bearing system, and carried out heat transfer analysis with the model. As a results, new type bearing cap which had several ribs for cooling the bearing was proposed. Finally, through the comparison between experimental results of old and new model pump, we proofed that maximum bearing temperature of new model was about 10% lower than that of old model.

Development of High Power BLDC Servo System for Control of Large Scale Mechanical System (대형 기계 구조물의 제어를 위한 대용량 BLDC 서보 시스템의 개발)

  • 정세교;김경화;송정민;김대준;김창걸;김원수;윤명중
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.982-986
    • /
    • 1996
  • The development of a high power BLDC servo system for a control of the large scale mechanical system is presented. Using DSP TMS320C30, a control unit which is suitable for motor drive system, is developed. Also, based on the developed control unit, BLDC drive system for the speed control is constructed. The algorithms of the vector control, current control, and speed control is implemented using TMS320C30 Software Development Tool. The developed high power BLDC motor drive system is applied to the large scale mechanical system and its feasibility is verified through the experimental results.

  • PDF

The Charcteristics Analysis of Linear Pulse Motor (선형 펄스 전동기의 특성 해석)

  • Jo, Yun-Hyeon;Lee, Gwang-Ho;Kim, Seong-Do
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.5
    • /
    • pp.249-256
    • /
    • 1999
  • This paper describes static characteristics analysis of linear pulse motor(LPM) with two permanent magnets. Linear pulse motors are finding a wide range of application for the Factory-Automation or the Office-Automation. Typically, LPM provides for a reliable and precise control of position, velocity, or acceleration without using a closed-loop system. Some of the advantages of LPMs are ease of control, step multiplication, static and dynamic positioning, and locking force. The flux density and thrust of LPM is computed by the FEM and magnetic equivalent circuits which considered the magnetic nonlinear phenomena. The result of characteristics analysis are shown as the flux, the air gap reluctance and the thrust. The velocity and position characteristics as a function of unit step input is measured. To estimate the unit step response charecteristic of LPM, the simulation results by Matlab and the experimental results is compared.

  • PDF

Seismic Qualification Test on Motor Control Center for Use in Nuclear Power Plants (원자력발전소용 Motor Control Center의 내진검증시험)

  • 김병현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.217-224
    • /
    • 1997
  • The safety related equipments for use in nuclear power plants should be subjected to the seismic qualification in order to insure the safety of the nuclear power plant. This paper summarizes the seismic qualification test on the Low Voltage Motor Control Centers(MCC's) for use in Wolsong Nuclear Power Plants, Units 2, 3 and 4. The seismic qualification test was performed on the two prototype MCC's(a two-bay wide unit for Phase #1 Test and a five-bay wide unit for Phase #2 Test). The specimens were electrically powered and monitored during the test process. It was demonstrated that the specimens possessed sufficient structural and electrical integrity to withstand the required seismic conditions.

  • PDF

Design and Temporal Analysis of Hardware-in-the-loop Simulation for Testing Motor Control Unit

  • Choi, Chin-Chul;Lee, Kang-Seok;Lee, Woo-Taik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.366-375
    • /
    • 2012
  • This paper describes a design and temporal analysis of a hardware-in-the-loop (HIL) simulation environment for testing a motor control unit (MCU). The design concepts and main characteristics including unavoidable time delays of each component module are described. From temporal analysis results according to the module integration method, an appropriate solution is proposed to fix and minimize time delays. In order to verify the effectiveness of the proposed solution, the HIL test results are compared with the results of experiments and an offline simulation.

Life Cycle Assessment on the Interior Panel of Electric Motor Unit (EMU) (전동차 내장판넬에 대한 전과정평가 연구)

  • Lee, Jae-Young;Choi, Yo-Han;Kim, Yong-Ki
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.5 s.36
    • /
    • pp.517-523
    • /
    • 2006
  • The sustainable development is a key issue in the whole field of economy, culture and society, which can be accomplished by the improvement of environment. Recently, life cycle assessment(LCA) has been applied to reduce environmental impacts preliminarily by evaluating the environmental performance of a product through its life cycle. In this study, life cycle assessment was performed to analyze quantitatively the environmental impact on the interior panel of electric motor unit(EMU). As a result, the interior panel with aluminum showed the most global warming(GW), while that with phenol and plastic showed high fresh water aquatic ecotoxicity(FAET) and marine water aquatic ecotoxicity(MAET), respectively. Global warming was occurred mainly due to the emission of $CO_2$ by energy consumption. FAET and MAET were caused by the pollutants released from acid-washing and paints coating process. Therefore, an environmental-friendly EMU can be designed considering the environmental impacts of interior panel.

The Performance Improvement of stopping for Induction Motor Using AC Drive (인버터를 이용한 유도전동기 감속 성능 개선)

  • Park, Kyeoung-Hun;Han, Kyung-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.296-297
    • /
    • 2011
  • Many applications involving induction motors that are controlled using variable frequency drives require the ability to stop quickly. These applications include emergency stops, quick stopping of fans, centrifuges, presses, etc. The technique that is widely accepted in the industry for achieving quick stopping makes use of brake resistors in series with a power semiconductor switch. The switch-resistor combination (brake-unit) is applied across the dc bus. The fastest decelerating time achievable depends on the size of the resistors and the switch employed. In this paper, the authors propose a novel method of achieving quick stopping times without the use of any brake-unit. Experimental test results with and without this method on a large inertia motor-load combination show that the proposed stopping method is able to reduce the stopping time significantly compared to normal decelerated stop without the need for a braking unit.

  • PDF

Evaluation of environmental impacts for the bogie of electric motor unit(EMU) using simplified life cycle assessment(S-LCA) (간략화된 전과정 평가를 이용한 전동차 대차의 환경영향 진단)

  • Kim Yong-Ki;Yoon Hee-Teak;Yang Yun-Hee;Lee Jae-Young
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.6 s.31
    • /
    • pp.581-585
    • /
    • 2005
  • In this study, the environmental impacts of a bogie in the electric motor unit(EMU) were evaluated quantitatively using simplified life cycle assessment(S_LCA). Target was the bogie and life cycle inventory(LCI) database for the bogie was established. The software used for simplified LCA was PASS. Environmental impacts with the parts of the bogie were dependent on their weight significantly. Among impact categories, abiotic resource depletion(ARD) and global warming(GW) were shown dominantly. Global warming was occurred mainly due to the emission of CO₂released from energy consumption and abiotic resource depletion was caused mostly by the consumption of iron ore for the manufacturing of steel. Therefore, the environmental impacts of the bogie could be reduced by the light-weighting of EMU and the improvement of energy efficiency.

Experiment for Position Accuracy Using Laser Scale Unit with 10 Nano-Meter Resoultion (10 nano-meter 분해능을 갖는 laser scale을 이용한 위치 결정 실험)

  • 임선종;정광조;최재완
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.21-26
    • /
    • 2000
  • This paper describes a positioning system for ultra-precision that will be utilized in semiconductor manufacturing field and precision machinery. This system is composed with laser scale unit with 10nm resolution, ball screw with LM guide, brushless DC servo motor, vibration isolator and is equipped in chamber for continuous measuring environment. The dynamic of table, the problem of servo control and the traceability for micro step motion are described. These data will be applied for getting more stable system with 50nm resolution.

  • PDF