Abstract
The purpose of this paper is to find a proper cooling system of bearing unit in the submersible motor pump to extend a life time. To do this, heat transfer analysis of the submersible motor pump were performed using commercial CFD code ANSYS. In order to obtain the resonable heat transfer simulation results, we first set up mathematical model of heat source in the bearing system, and carried out heat transfer analysis with the model. As a results, new type bearing cap which had several ribs for cooling the bearing was proposed. Finally, through the comparison between experimental results of old and new model pump, we proofed that maximum bearing temperature of new model was about 10% lower than that of old model.
Keywords
bearing; heat transfer; pump; temperature distribution;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Moon, J. H, Moon, S. J., and Lee, J. H, "Thermal Reliability Analysis of the Bearing Units in a Centrifugal Pump," Korean Journal of Air-Conditioning and Refrigeration, Vol. 19, No. 4, pp. 313-320, 2007.
2 FAG Bearing Catalog (WL 41 520/4 KA), 2002.
3 Choi. D. B, Kim. S. T, Jung. S. H., and Kim. Y. K, "Thermal Characteristics According to the Preload and Cooling Conditions for the High Frequency Motor Spindle with Grease Lubrication," 2004 Spring Conference of Korean Society of Machine Tool Engineer, pp. 439-444, 2004.
4 Lim. J. S, Yu, K. H, Chung. W. J, Kim. S. T, Lee. J. H., and Lee. C. M, "Thermal Characteristics Analysis of 30,000 rpm High Speed Spindle," Journal of the Korean Society for Precision Engineering, Vol. 26, No. 7, pp. 120-126, 2009.
5 Han, S. K, Kang, B. H., and Lee, B. J, "Prediction of Oil Lifetime due to Overheating of Oil and Bearing Housing in a Pump," Korean Journal of Air-Conditioning and Refrigeration, Vol. 19, No. 5, pp. 408- 413, 2004.