• 제목/요약/키워드: Motor Driven Inverter

검색결과 186건 처리시간 0.031초

슬롯피치 경계 조건을 이용한 인버터 구동 유도 전동기의 회전자 등가회로 정수 추출 및 특성해석 (Analysis of Inverter-Fed Induction Motor Using F.E.M and Harmonic Equivalent Circuit)

  • 이건호;김병태;권병일
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권7호
    • /
    • pp.331-338
    • /
    • 2002
  • An inverter-fed induction is driven by a harmonic voltage source so that it is necessary to be analysed by time-stepping F.E.M. But it takes so long time that disadvantageous to design. This paper presents a simple analysis method for inverter-fed induction motor using FEM and harmonic equivalent circuit. First, the rotor bar resistance and the leakage reactance are determinated by FEA for 1 slot region in rotor to consider the skin effect and the saturation. Secondly, the characteristic of the motor is analyzed by the harmonic equivalent circuits consisting of the obtained parameters from the FEA. This method is carried out to analyze an induction motor driven by the sinusoidal voltage and the inverter. The results are verified by comparing with those of the time-step F.E.A and the experiment.

전브리지 공진형 인버터에 의한 단상 유도전동기의 디지탈 제어에 관한 연구(2) (A Study on the Digital Control of Single Phase Induction Motor Driven by the Full Bridge Resonant Inverter(2))

  • 노영오;박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권5호
    • /
    • pp.86-98
    • /
    • 1993
  • The application of A.C. motor for servo system is rapidly increased according to the recent advance of power electronics and digital control techniques. The induction motor which has a simple structure and needs less maintenance has become to be used widely in the industrial field for the speed and position control recently. In this paper, the full-bridge resonant inverter is applied to the speed control of single phase inducting motor. The digital PID control algorithm is used and the control parameter is determined by the Zigler-Nichols transient response method. The speed control is carried out by the one chip micro-processor(intel EV 8097BH) and control program is developed by the assembly language. By the experimental result, it is confirmed that the speed of single phase induction motor driven by full bridge series inverter can be smoothly controlled by a digital PID controller.

  • PDF

Rotor Fault Detection System for the Inverter Driven Induction Motor using Current Signals

  • Kim, Nam-Hun;Baik, Won-Sik;Kim, Min-Huei;Choi, Chang-Ho
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.224-231
    • /
    • 2009
  • The induction motor rotor fault diagnosis system using current signals, which are measured using an axis-transformation method, is presented in this paper. In inverter-fed motor drives, unlike line-driven motor drives, the stator currents are rich in harmonics; therefore fault diagnosis using stator current is not trivial. The current signals for rotor fault diagnosis need precise and high resolution information, which means the diagnosis system demands additional hardware such as a low pass filter, high resolution ADC, and encoder, etc. The proposed axis-transformation method with encoder and without encoder is expected to contribute to a low cost fault diagnosis system in inverter-fed motor drives without the need for any additional hardware. In order to confirm the validity of the developed algorithms, various experiments for rotor faults are tested and the line current spectrum of each faulty situation using Park transformation is compared with the results obtained from fast Fourier transforms.

IGBT 인버터 구동 유도전동기 고정자 권선에서의 과도전압 분포 해석 (Analysis of Overvoltage Distribution in Stator Winding of Induction Motor Driven by IGBT PWM Inverter)

  • 배성우;황돈하;김용주;김동희;김민회;이인우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.17-20
    • /
    • 2002
  • In this paper voltage distribution in stator windings of induction motor driven by IGBT PWM inverter is studied. To analyze the irregular voltage of stator winding, equivalent circuit model of inverter-cable-motor was proposed and high frequency parameter is computed by using finite element method (FEM). Electro-magnetic transient program (EMTP) analysis of the whole system for induction motor and PWM inverter is proposed. Induction motor, 50[HP], and a switching surge generator was built to consider the voltage distribution. The results of EMTP analysis compared with experimental results.

  • PDF

영구자석 동기전동기 구동 인버터 스위치의 개방 고장에 의한 제어 특성해석 및 고장모델 연구 (A Study on Fault Model end Performance Evaluation under Power Switch Open Fault in an Inverter-Driven Permanent Magnets Synchronous Motor)

  • 김경화;최동욱;구본관;정인성
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.40-51
    • /
    • 2009
  • 인버터 스위치의 개당 혹은 인버터와 모터 터미널의 분리로 인해 발생하는 고장을 해석하고 진단 알고리즘의 시험 평가를 위해 효과적으로 사용할 수 있는 영구자석 동기전동기 구동 인버터의 개방 고장에 의한 제어 특성해석 및 고장모델이 제시된다. 기존의 전동기의 해석과 제어에 많이 사용되는 dq 모델은 상전압 모델을 변환한 것으로 고장 상황에서는 3상평형 조건이 성립하지 않기 때문에 개방 회로의 입력 전압을 구하기가 쉽지 않아 고장 모델의 해석을 위해 직접 사용하기 어렵다. 이를 해결하기 위해 스위치 개방에 따른 전통기의 선전압 관계를 이용한 인버터의 고장 모델이 제안되고 제안된 고장모델의 타당성을 입증하기 위해 시뮬레이션이 수행된다. 전체 시스템이 DSP TMS320F28335에 의해 구현되어 동일 고장 조건에서의 비교 실험과 특성 해석이 수행된다.

Space-vector PWM Techniques for a Two-Phase Permanent Magnet Synchronous Motor Considering a Reduction in Switching Losses

  • Lin, Hai;Zhao, Fei;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.905-915
    • /
    • 2015
  • Two PWM techniques using space vector pulse-width modulation (SVPWM) are proposed for a two-phase permanent magnet synchronous motor (PMSM) driven by a two-phase eight-switch inverter. A two-phase motor with two symmetric stator windings is usually driven by a two-phase four-, six-, or eight-switch inverter. Compared with a four- and six-switch inverter, a two-phase eight-switch inverter can achieve larger power output. For two-phase motor drives, the SVPWM technique achieves more efficient DC bus voltage utilization and less harmonic distortion of the output voltage. For a two-phase PMSM fed by a two-phase eight-switch inverter under a normal SVPWM scheme, each of the eight PWM trigger signals for the inverter have to be changed twice in a cycle, causing a higher PWM frequency. Based on the normal SVPWM scheme, two effective SVPWM schemes are investigated in order to reduce the PWM frequency by rearranging four comparison values, while achieving the same function as the normal PWM scheme. A detailed explanation of the normal and two proposed SVPWM schemes is illustrated in the paper. The experimental results demonstrate that the proposed schemes achieve a better steady performance with lower switching losses compared with the normal scheme.

상용인버터 구동 유도전동기의 마이크로 서지 및 노이즈 억제에 관한 대책 (Countermeasure on the Suppression of Micro Surge and Noise for a Induction Motor Driven by Commercial Inverter)

  • 김덕현;최정원
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.111-117
    • /
    • 2008
  • 일반적으로 산업현장에서 널리 사용되는 유도전동기는 상용인버터를 이용하여 속도제어를 하게 된다. 상용인버터로 구동되는 유도전동기는 인버터의 고속 스위칭에 의한 마이크로 서지전압을 발생한다. 이러한 마이크로 서지는 전동기의 소손뿐 만아니라 PLC 제어계통에 있어서 노이즈 문제를 발생하며, 생산 활동에 막대한 지장을 초래하게 된다. 본 논문에서는 마이크로 서지의 발생 메커니즘을 살펴본 후 전동기 소손 방지를 위한 대책을 제시하고 인버터 출력단에 LCR 필터를 부착하여 실험하였으며 결과로 마이크로 서지전압이 저감됨을 확인하였다 또한 PLC 제어계통의 노이즈 억제에 대해 이론적 고찰을 통해 대책도 제시하였다.

대용량 인버터 구동 전동기 고조파 손실해석 (The Harmonic Loss Analysis for Inverter Driven Large Induction Motor)

  • 이정일;박정태;권병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1047-1048
    • /
    • 2007
  • In this paper, the harmonic loss of the inverter driven induction motor was analyzed. It was analyzed through the theoretical consideration on the variations of equivalent circuit constants, and harmonic losses, including the effects of resistance increase and inductance decrease of stator, not through the general method that considering just the effects of the harmonic losses of only the rotor. It was verified by comparing the harmonic analysis results with the test results for HHI's inverter driven motor.

  • PDF

Development of Traction Unit for 2-motor Driven Electric Vehicle

  • Park, Jung-Woo;Koo, Dae-Hyun;Kim, Jong-Moo;Kim, Heung-Geun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.950-954
    • /
    • 1998
  • This paper describes a development of traction unit for 2-motor driven electric vehicle (EV). The traction unit is consisted with an interior permanent magnet synchronous motor (IPMSM), a reduction gear and an inverter for electric vehicle that is driven by 2 motors without differential gear. For traction unit, prototype IPMSM and inverter have been developed. The IPMSM was designed by CAD program that was developed with both equivalent circuit method and FEM. Also the inverter was developed to drive 2 motors with 6 legs IGBT switches in a control board. The vector control algorithm was implemented with maximum torque control method in the constant torque region and field weakening control method in the constant power region considering inverter capacity. To verify that the traction unit is more high efficiency and has more high power density than a traction unit with induction motor with the same power, we would like to show the results about the design and analysis of the IPMSM and the experiment results about the traction unit.

  • PDF

오버샘플된 전류신호를 사용한 인버터 구동형 전동기의 베어링 고장검출 시스템 (High Precison Bearing Fault Detect System of Inverter Driven System Using Oversampled Current Signals)

  • 김남훈;김민회;최창호;이상훈;최경호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.506-508
    • /
    • 2007
  • In this paper, the induction motor bearing fault diagnosis system using current signals which are measured by over-sampling method is presented. In the case of inverter fed motor drive unlike line-driven motor drive, that make a lot of noise which can cause a wrong fault signals because of PWM(pulse width modulation) voltage. So, the current signals for fault diagnosis need very precise and high resolution information, which means this system demand additional hardware such as low pass filter, high resolution ADC system and so on to use fault diagnosis system. Therefore, the proposed over-sampling method is expected to contribute to low cost fault diagnosis system even though previous inverter fed motor drive without any additional hardware. In order to confirm the presented algorithms, various experiments for bearing faults are tested and the line current spectrum of each faulty situation using park transformation is compared with a FFT results.

  • PDF