• Title/Summary/Keyword: Motional characteristic

Search Result 9, Processing Time 0.029 seconds

Effects of sperm motional characteristics on pregnancy rate in HanWoo (Bos taurus coreane) (정자의 운동특성이 인공수정 수태율에 미치는 영향)

  • Lee, Seoung-soo;Kim, Duk-im;Park, No-hyoung;Won, You-seog
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.1
    • /
    • pp.187-195
    • /
    • 2000
  • The ejaculates from 67 HanWoo prove bull, bred in Livestock Improvement Main center of NLCF, were used to determine the correlation between the sperm motional characteristics and the pregnancy rate of artificial insemination(AI). The motional characteristics of sperm were analysed by Computer-assisted sperm analyser(CASA), thereafter inseminated equally 1,256 heads of cow regarding to parity, age, and live weight. There were no significant difference(p>0.05) in the pregnancy rate according to year from 1996 to 1998, but the LIN, ALH, STR, BCF, MAD and WOB of sperm in the year 1997, were highest pregnancy rate, were higher than those of sperm in the year 1998, were lowest pregnancy rate(p<0.05). The semen had no significant effect on pregnancy rate according to season(p>0.05). However spring, had a little higher pregnancy rate than that of autumn, were higher than autumn in VSL, VAP, LIN, ALH, BCF, MAD and WOB, but in DNM. The pregnancy rates of spring in the year 1996 and 1997 were higher than that of autumn in the year 1998(p<0.05). The spring in the year 1997, highest in pregnancy rate, were higher than the autumn in the year 1998 in VSL, VAP, LIN, STR, BCF, MAD and WOB, but in DNM(p<0.05). There were no the motion characteristic of sperm that was significant correlate with pregnancy rate of AI as the semen were analysed before artificial insemination and those, had some degree characteristics in motility, viability and abnormality, were used to AI. However there were a tendency that the higher the VSL, VAP, ALH, LIN, STR, BCF, MAD and WOB and the lower the DNM were, the higher the pregnancy rate of AI were.

  • PDF

Analysis of Moving Body Characteristics by Coupling Finite Element Method and Motion Equation (유한요소법과 운동방정식의 결합에 의한 운동체의 특성 해석)

  • 김영선;이준호;이기식;이복용
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.5
    • /
    • pp.281-286
    • /
    • 1996
  • For the accurate analysis of motional characteristics of electrical machines, it is needed to solve the motion equations together with the electromagnetic field equations. In this paper the sequential coupling of systems, the spring mass system and the electromagnetic system, is adopted. The induced current and the magnetic fields are calculated by finite element method(FEM) with given speed. And then, with the computed elec-tromagnetic force, the mechanical equations are solved by the Runge-Kutta method. The above two processes are repeated sequentially to obtain the time domain solutions. The resultant values are applied to the energy conservation law to prove the usefulness of the proposed sequential method.

  • PDF

A Study on the Running Type Nipper Pattern Development for Adult men (성인 남성용 런닝형 니퍼패턴 개발)

  • Cho, Pyeong-Hun;Shon, Hoo-Jo;Na, Mi-Hyang
    • Korean Journal of Human Ecology
    • /
    • v.16 no.3
    • /
    • pp.577-585
    • /
    • 2007
  • This research aimed for 20 latter man whose body shape of torso alters remarkably to develop nipper pattern of running type considered characteristic of body shape of 20 latter man to keep rather balanced body shape against middle age when body shape changes extremely. 1. running type nipper pattern design. Pattern of running, lining and nipper were designed by flattening surface shell. A basis line of running pattern is completed by applying reduction ratio after 3 times of modification & complement based on surface shell. Nipper pattern is designed with design line set by a plaster cast based on running pattern line. Lining pattern is designed with lining design line set by a plaster cast based on running type outside material and nipper pattern. 2. Functional evaluation of research and commercial nipper. Functional inspection through dress test was applied 5point evaluation method and the result of functional inspection on the sight of a wearer is that research nipper(running reduction ratio 15%, nipper reduction ratio 18%) averaged more 4.8point but commercial nipper averaged less 1.8point in the aspect of 20 items such as wear sensibility, motional function and external appearance aesthetic. Research running type nipper scored high in order of motional function, looks of side, back, front and whole and wear sensibility. Functional inspection in the point of view of an observer is that research nipper(running reduction ratio 15%, nipper reduction ratio 18%) averaged over 4.8point and commercial nipper averaged under 1.9point in 17 items of external appearance beauty. Research running type nipper marked high in order of looks of back, whole, front and side.

Characteristic Analysis Of A Single-Sided Linear Induction Motor Taking account of Movement (이동을 고려한 편측식 선형 유도 전동기의 특성 해석)

  • Im, D.H.;Kwon, B.I.;Kim, C.E.;Jung, Y.B.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1060-1062
    • /
    • 1993
  • This paper presents the dynamic analysis method of a linear induction motor by finite element method. For simulation of dynamic performance, a step by step process with respect to time is used with external voltage source and motional equation. Movement is taken into account by a combination of mesh distortion and remeshing technique.

  • PDF

Orientation of Liquid Crystal and Electro-Optic Characteristic Effect of dispersed Carbon nanotubes in In Plane Switching Cell (탄소 나노 튜브가 분산된 수평전기장을 이용한 액정 셀의 액정 방향성과 전기 광학특성 연구)

  • Jeon, Sang-Youn;Baik, In-Su;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.520-521
    • /
    • 2005
  • To observe the orientation of carbon nanotubes (CNTs) dispersed in nematic liquid crystal (NLC), CNT-doped homogeneously-aligned NLC cells driven by in-plane field was fabricated. The CNTs were aligned with a LC director in the initial state, whereas the CNTs disturbed the LC director above critical ac field. We observed motional textures in the form of vertical stripes in the local area between electrodes, which were associated with a deformation of the LC director orientation. This suggests that CNTs start to vibrate three dimensionally with translational motion. The hysteresis studies of voltage-dependent transmittance under dc electric field show that the amount of residual dc is greatly reduced due to ion trapping by CNT.

  • PDF

Analysis of Serial Piston Actuator on the Dynamic Characteristics by Electromechanical Energy Conversion (에너지 변환론에 의한 직선형 피스톤 액추에이터의 동작 특성 해석에 관한 연구)

  • 김양호;이해경;황석영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.110-114
    • /
    • 2004
  • This paper deals with the dynamic characteristic analysis of linear actuator(LA) considered with coupling of mechanical spring system This application of linear actuator is increasing due to simple mechanical structure, a high efficiency, and a stable motional action. This paper proposed and analyzed the Serial Piston Actuator(SPA) by using mechanical spring system coupled with linear actuator through the simplified structure which was verified practical experiments.

Equivalent Impedance Modelling and Frequency Characteristic Analysis of Linear Oscillatory Actuator System Considering Mass/spring System (질량/스프링 계를 고려한 리니어 왕복 액추에이터 시스템의 등가 임피던스 모델링과 주파수 특성 해석)

  • Jeong, Sang-Seop;Jang, Seok-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.7
    • /
    • pp.370-378
    • /
    • 2002
  • As resent trends in structural construction have been to build taller and larger structures than any time in the past, they have had high flexibility and low damping that can cause large vibration response under severe environmental loading such as earthquakes, winds, and mechanical excitations. The damper with mass and spring is one approach to safeguarding the structure against excessive vibrations. In this paper, the lumped electrical circuit approach of mass/spring system is used to model the mechanical aspects according to the frequency. Therefore, the mass/spring system can be dealt with here and linked with the equivalent circuit of electric linear oscillatory actuator(LOA). Analysis models are two types of vibration control system, active mass damper(AMD) and hybrid mass damper(HMD). AMD consists of the moving coil LOA with mass only The LOA of HMD with mass and spring is composed of the fixed coil and the movable permanent magnet(PM) field part. The PM field part composed magnet modules and iron coke, is the damper marts itself. We Present the motional resistance and reactance of mass/spring system and the system impedance of AMD and HMD according to the frequency.

Effects of Dispersed Carbon nanotubes on Electro-Optic Characteristics and Orientation of Liquid Crystal in the In-Plane Switching Cell

  • Baik, I.S.;Jeon, S.Y.;Choi, J.Y.;Lee, S.H.;Lee, J.Y.;An, K.H.;Lee, Y.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.415-418
    • /
    • 2005
  • To understand effects of carbon nanotubes (CNTs) dispersed in nematic liquid crystal (NLC) on electro-optic characteristic and orientation of the LC, we CNT-doped homogeneously-aligned NLC cells driven by in-plane field have been fabricated. The CNTs were aligned with a LC director from the initial state to below critical ac field, whereas the CNTs disturbed the LC director field above critical ac field. We observed motional textures in the form of vertical stripes in the local area between electrodes, which were associated with a deformation of the LC director orientation. This indicates that CNTs start vibrating three dimensionally with translational motion. Further, the hysterisis studies of voltage-dependent transmittance under dc electric field show that the amount of residual dc, which is related to image sticking problem in liquid crystal displays, is greatly reduced due to ion trapping by CNTS while keeping operating voltage and response time about the same compared to the un-doped LC cell.

  • PDF

A Trial for Development of Health Profile (KHP 1.0) to Measure the Self-Perceived Health Status of Korean (한국인의 자가평가 건강수준 측정도구(KHP 1.0) 개발)

  • Yang, Jin-Sun;Chun, Jin-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.1
    • /
    • pp.11-23
    • /
    • 2003
  • Objectives : The 1990s has seen advances in the conceptualization of self-perceived health status which has important roles for individual health and the quality of life. Many types of standardized questionnaires have been developed with the current wide use of SF-36, NHP, andEuroQol. However, the outcomes of these tools may be different with regard to regional, cultural and emotional backgrounds. The purpose of this study was to trial the development of a Korean Health Profile (KHP 1.0) to measure the self-perceived health stati of Koreans. Methods : The KHP 1.0 was designed on the basis of the Medical Outcome Study Form 36 (SF-36), the Nottingham Health Profile (NHP), and the EuroQOL. It was composed of 9 scales; physical functioning, role limitation-physical, pain, general health, energy, social isolation, sleep, role limitation-emotional, and e-motional health. Self-reported chronic disease conditions, and the Zung's Self-Rating Depression Scale (SDS), were also checked for the evaluation of clinical validity. This study was conducted, from December 2000 to January 2001, on 800 middle-aged parents, with four high school students, with 100 retest sets being conducted two weeks later. From the 800 subjects there were 588 complete responses (effective response 73.5%). The reliability of the test-retest results, and the factor analysis on the validity of the KHP 1.0 components, were evaluated using the SPSS (ver 10.0) software. Results : The reliability of the KHP 1.0 was good with Cronbach's alpha (>0.6), test-retest correlation coefficients (>0.5), but with no significant differences from the paired t-test. From the psychometric validity tests, the 9 scales of the KHP 1.0 were divided into two components; physical and mental, and trimmed to the established model with 55% of the total variance, with the exception of role limitation-emotional. The clinical validity on the basis of the comparison for the four characteristic groups; healthy, physical conditions only, mental conditions only, and physical and mental conditions were also good. Conclusions : The KHP 1.0 appears to be a valid measurement tool of self-perceived health stati of Koreans, although there are limitations, i.e. sample size was too small, a limited number of middle-aged subjects, and it was based on unconfirmed diagnoses, etc. Therefore, further study is required to standardize the assessment.