• Title/Summary/Keyword: Motion reduction device

Search Result 54, Processing Time 0.506 seconds

Data Reduction and Analysis of the Resonant Column Testing Based on the Equation of Motion (운동방정식에 기초한 공진주 실험의 자료분석 및 해석)

  • 조성호;강태호
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.133-144
    • /
    • 2003
  • The resonant column testing is a laboratory testing method to determine the shear modulus and material damping factor of soils. The method has been widely used for many applications and its importance has increased. Since the first use of the testing method in 1960's, the low-technology electronic devices fir testing and data acquisition have limited the measurement only to the amplitude of the linear spectrum. The limitations of the testing method are also attributed to the assumption of linear-elastic material in the theory of the resonant column testing and also to the incomplete understanding of the dynamic behaviour of the resonant column testing device. Recently, Joh et al. proposed a theory to overcome the limitations of the resonant column testing by deriving the equation of motion and providing its solution for the resonant column testing device. This study proposed the improved data reduction and analysis method for the resonant column testing, thanks to the advanced data acquisition system and the new theoretical solution for the resonant column testing system. For the verification of the proposed data reduction and analysis method, the numerical simulation of the resonant column testing was performed by the finite element analysis. Also, a series of resonant column testing were performed fir Joomunjin sand, which verified the feasibility of the proposed method and revealed the limitations of the conventional data reduction and analysis method.

The Effects Where the Stroke Shoes Which Use Functional Electric Stimulation Goes Mad to Walking of the Hemiplegia (기능적 전기자극 치료기를 이용한 중풍구두가 편마비 환자의 보행에 미치는 영향)

  • Kim, Jeong-Seon;Park, Ji-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.1
    • /
    • pp.36-43
    • /
    • 2007
  • Purpose: An objective analysis and observations were to be done on hemiplegia patients that are wearing a walking support device, Stroke shoes. Their improvements in walking pace, the reduction of distance between the two knee joint, the increase of curve angle of the knee joint and their steps and the reduction of ankle joint upon swing phase were analyzed using a 20 walking analyzer. Methods: An examination was carried out to see the patients' communication skill and independent walking and then let them walk with the Stroke shoes on to get results before and after wearing it. Simi Reality Motion Systems GmbH (Germany, 2007) was used to analyze the results regarding knee joint and ankle joint angle changes of sagitta plane and coronal plane, stepping distances, distances between the knees and walking pace. Results: 1. The articulation angle of ankle joint during swing phase decreased and knee joint has shown a statistically significant increase in such value(p<0.05). 2. Only knee joint showed a significant increase in articulation angle during heel strike(p<0.05). 3. Knee joint showed a significant increase in articulation angle during toe off(p<0.05). 4. The distance between the two knees as well as their foot steps significantly decreased compared with when Stroke shoes were not worn(p<0.05). 5. Stroke shoes with FES have shown positive effects on the patients in improving their walking styles overall. (p<0.05). Conclusion: There was an improvement in rotation walking pattern by a reduction in the distance between the knees after wearing Stroke shoes with FES. Plantar flexion reduced that occurred in ankle joint during walking and flexion angle increased in knee joint, both of which improved foot drop which was a major problem in hemiplegia patients. Also it is believed that the device will have some positive influences on knee joint stiffening paralysis to aid in improving inefficient walking phases.

  • PDF

Rolling Reduction of Floating body by Anti-Rolling Pendulum (안티롤링 추를 이용한 부유체의 롤링 저감)

  • Park, Sok-Chu;Park, Kyung-Il;Yi, Geum-Joo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2016.05a
    • /
    • pp.106-107
    • /
    • 2016
  • Rolling motion of floating body might upset the body, make crews and passengers exhausted and/or apply forces to the structure to cause damage. Therefore for almost ships bilge keels are equipped, in special case fin stabilizer or gyroscope may be installed. This paper suggests the Anti-rolling pendulum to reduce roll motion to act the similar role with anti-rolling tank. The device suggested has more effective than the anti-rolling tank with 1/6 volume of the tank.

  • PDF

A Study on the Sliding Ball Joint of Parallel Kinematic Mechanism (병렬 운동 기구의 미끄럼 볼 조인트 개발에 관한 연구)

  • Yoo, Dae-Won;Lee, Jai-Hak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.9
    • /
    • pp.982-989
    • /
    • 2009
  • Parallel Kinematic Mechanism (PKM) is a device to perform the various motion in three-dimensional space and it calls for six degree of freedom. For example, Parallel Kinematic Mechanism is applied to machine tools, medical equipments, MEMS, virtual reality devices and flight motion simulators. Recently, many companies have tried to develop new Parallel Kinematic Mechanism in order to improve the cycle time and the precisional tolerance. Parallel Kinematic Mechanism uses general universal joint and spherical joint, but such joints have accumulated tolerance problems. Therefore, it causes position control problem and dramatically life time reduction. This paper focused on the rolling element to improve sliding precision in new sliding ball joint development. Before the final design and production, it was confirmed that new sliding ball joint held a higher load and a good geometrical structure. FEM analysis showed a favorable agreement with tensile and compressive testing results by universal testing machine. In conclusions, a new sliding ball joint has been developed to solve a problem of accumulated tolerance and verified using tensile and compressive testing as well as FEM analysis.

Swing Noise Reduction of an Excavator (굴삭기의 선회소음 저감)

  • Lee, Soyeon;Won, Hong-In;Kim, Woohyung;Kim, Seongjae;Kim, Indong;Chung, Jintai
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.6
    • /
    • pp.391-398
    • /
    • 2015
  • The swing noise of an excavator is reduced in this study. When an excavator is under a swing motion, it produces the annoying noise which is required to be reduced. To identify the characteristics of the swing noise, the signals of noise and vibration from an excavator are measured during the swing motion. From the variation of the driving motor speed, the noise and vibration signals are picked up and plotted in the waterfall plots. From the waterfall plots, we identify the frequency components corresponding to the driving motor frequency, the gear mesh frequency of the planetary gear, and their harmonics. In addition, the natural frequencies and modes of the center frame are extracted by using the experimental modal test. It is found that the swing noise is amplified when the gear mesh frequencies coincide with the natural frequencies of the center frame. To reduce the swing noise, the structural modification is performed to the center frame. Finally, it is observed that the noise is considerably reduced by the structural modification.

A Study on the Performance of Dynamic Restraint Manipulator for Drilling Alveolar Bone in Mandible (하악골의 치조골 골삭제를 위한 동적 제약 기구부의 성능에 관한 연구)

  • Kim, Gwang-Ho;Lee, Dong-Woon;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.12
    • /
    • pp.105-112
    • /
    • 2020
  • The increase in the edentulous jaw which occurs in the aged population has led to personal dental health concerns. In the case of dental implant surgery, the duration of a patient's recovery depends on the surgical plan and their physicical ability. A device may be required to assist a physician in controlling vibration reduction of free-hand drilling and prescribing a good treatment plan that is suitable for the patient's condition. In this work, an artificial tooth-root implant assistant manipulator was studied. The structure and the vibration analysis of the dynamic restraint manipulator that is for drilling the alveolar bone in the mandible bone were performed, and the structural stability was analyzed. Further, a virtual prototype of an artificial tooth-root implant assisted manipulator was fabricated and tested. Hence, the state of the Remote Center of Motion (RCM) point and the driving state of the manipulator were confirmed. Furthermore, the drilling experiments were performed by using materials similar to a human jawbone in order to evaluate the performance of the drilling process that is operated using the assistant manipulator.

Family of smart tuned mass dampers with variable frequency under harmonic excitations and ground motions: closed-form evaluation

  • Sun, C.;Nagarajaiah, S.;Dick, A.J.
    • Smart Structures and Systems
    • /
    • v.13 no.2
    • /
    • pp.319-341
    • /
    • 2014
  • A family of smart tuned mass dampers (STMDs) with variable frequency and damping properties is analyzed under harmonic excitations and ground motions. Two types of STMDs are studied: one is realized by a semi-active independently variable stiffness (SAIVS) device and the other is realized by a pendulum with an adjustable length. Based on the feedback signal, the angle of the SAIVS device or the length of the pendulum is adjusted by using a servomotor such that the frequency of the STMD matches the dominant excitation frequency in real-time. Closed-form solutions are derived for the two types of STMDs under harmonic excitations and ground motions. Results indicate that a small damping ratio (zero damping is the best theoretically) and an appropriate mass ratio can produce significant reduction when compared to the case with no tuned mass damper. Experiments are conducted to verify the theoretical result of the smart pendulum TMD (SPTMD). Frequency tuning of the SPTMD is implemented through tracking and analyzing the signal of the excitation using a short time Fourier transformation (STFT) based control algorithm. It is found that the theoretical model can predict the structural responses well. Both the SAIVS STMD and the SPTMD can significantly attenuate the structural responses and outperform the conventional passive TMDs.

Research of Mobile 3D Dance Contents Construction Using Motion Capture System (모션캡처 시스템을 이용한 모바일 3D 댄스 콘텐츠 제작 연구)

  • Kim Nam-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.9
    • /
    • pp.98-107
    • /
    • 2006
  • By improving performance of mobile machine(3D engine, 3D accelerator chip set, etc) and developing wireless network technology, a demand for actual contents of users is being increased rapidly. But, there are some difficulties yet for the speedy development of actual contents because of the limitation of development resources that is dependent on each mobile device's different performance. In general, much of the animated character-creation work for mobile environment is still done manually by experienced animator with the method of key frame processing. However, it needs a lot of time and more costs for creating motion. Additionally, it is possible to cause a distortion of motion. In this paper, I solved the difficulties by using a optical motion capture system, it was able to acquire accurate motion data more easily and quickly, and then it was possible to make 3D dance contents efficiently. Also, I showed techniques of key reduction and controlling frame number for using huge amounts of motion capture data in mobile environment which requires less resources. In making 3D dance contents, using an optical motion capture system was verified that it was more efficient to make and use actual-reality contents by creating actual character motion and by decreasing processing time than existing method.

  • PDF

A Study on Vibration Control of a Beam Using Magnetostrictive Actuators (자기변형 구동기를 이용한 보의 진동제어)

  • 임채욱;문석준;정태영;박영진
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.433-438
    • /
    • 2003
  • In this paper we explore the effectiveness of a magnetostrictive actuator(MSA) as a structural control device. A series of numerical and experimental tests are carried out with a simple aluminum beam only supported at each end by the actuator. After the equation of motion of the controlled system is obtained by the finite element method, a model reduction is performed to reduce the numbers of degree of freedom. A linear quadratic feedback controller is realized on a real-time digital control system to damp the first four elastic modes of the beam. Through some tests, we confirmed the possibility of this actuator for controlling beam-like structures.

  • PDF

The Method to Reduce the Driving Time in (sLa-Camera-pRd) type ((sLa-Camera-pRd)타입의 구동시간 단축 방법)

  • Kim, Soon-Ho;Kim, Chi-Su
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.1-7
    • /
    • 2018
  • Gentry is responsible for moving the fine chip in the device that mounts the chip on the PCB. However, it is not easy to increase productivity because of the mechanical limitations of the gantry. Therefore, in this paper, we try to solve the method to increase the productivity by software. For this purpose, we propose a method to improve the productivity by shortening the movement time of the gantry. First, we calculated the total travel time for the current method(stop-motion). In addition, the total travel time is also calculated for the travel time reduction method presented in this paper. This method reduces the travel time by checking parts without stopping in front of the camera. As a result, we showed that the proposed method shortened the time of 16%. In the future, we will study time calculation methods for other types.