• 제목/요약/키워드: Motion Comparison

검색결과 1,234건 처리시간 0.025초

차량 전복 방지를 위한 롤 및 요 운동 제어기의 성능 비교 (Comparison Among Yaw and Roll Motion Controllers for Rollover Prevention)

  • 임성진
    • 제어로봇시스템학회논문지
    • /
    • 제20권7호
    • /
    • pp.701-705
    • /
    • 2014
  • This article presents a comparison among several yaw and roll motion controllers for vehicle rollover prevention. In the previous research, yaw and roll motion controllers can be independently designed for rollover prevention. Following this idea, several yaw and roll motion controllers are designed and compared in terms of rollover prevention. For the yaw motion control, PID, LQR, SMC (Sliding Mode Control) and TDC (Time-Delay Control) are adopted. For the roll motion control, LQR, LQ SOF (Static Output Feedback) control, PID, and SMC are adopted. To compare the performance of each controller, simulation is performed on a vehicle simulation package, CarSim$^{(R)}$. From simulation, TDC and LQ SOF are the best for yaw and roll motion control, respectively.

탄성밴드를 이용한 저항운동이 회전근개봉합술 환자의 견관절가동범위와 기능 및 통증에 미치는 효과 (Effects of Resistance Exercise using Elastic Band on Range of Motion, Function and Shoulder Pain among Patients with Rotator Cuff Repair)

  • 심재옥
    • 성인간호학회지
    • /
    • 제28권5호
    • /
    • pp.491-500
    • /
    • 2016
  • Purpose: The purpose of this study was to examine the effect of resistive exercise using an elastic band on range of motion, function and shoulder pain. Methods: Forty two subjects who had rotator cuff surgery were assigned either to a treatment or a comparison group, twenty one each. Following a six week period after surgery those in the treatment group participated in resistant exercise using an elastic band for four weeks. The subjects in the comparison group did not participate in the exercise program. The goniometer measured range of motion, a modified tool measured function, and a self report numerical rating scale measured pain. The data were analyzed using $x^2$ test, Fisher's exact, t-test and the Mann-Whitney Test. Results: Although not statistically significant, there was a trend that more subjects in the treatment group had increased range of motion. There was a statistically significance among the treatment group in terms of increased function (p=.015). Further the treatment group reported less pain that those in the comparison group (p<.001). Conclusion: The findings support that resistance exercise is an effective strategy for patients with rotator cuff repair.

인공 매립 지반에서의 지진파 증폭 특성 (Seismic Motion Amplification Characteristics at Artificial Reclaimed Land)

  • 김용성;문용
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1134-1139
    • /
    • 2005
  • Seismic motion amplification owing to the input motion level at bedrock is one of the important topics to understand various geomaterials behavior. The extremely valuable borehole records at Port Island were obtained during the 1995 Hyogoken Nanbu Earthquake and also before and after the main event. In this study, the seismic motion amplification at the soft reclaimed ground was discussed. Comparison of measured records with numerical simulation results were made with focus on seismic motion amplification characteristics at the soft reclaimed ground.

  • PDF

다중선형회귀모델을 이용한 움직임 추정방법 (Motion estimation method using multiple linear regression model)

  • 김학수;임원택;이재철;이규원;박규택
    • 전자공학회논문지S
    • /
    • 제34S권10호
    • /
    • pp.98-103
    • /
    • 1997
  • Given the small bit allocation for motion information in very low bit-rate coding, motion estimation using the block matching algorithm(BMA) fails to maintain an acceptable level of prediction errors. The reson is that the motion model, or spatial transformation, assumed in block matching cannot approximate the motion in the real world precisely with a small number of parameters. In order to overcome the drawback of the conventional block matching algorithm, several triangle-based methods which utilize triangular patches insead of blocks have been proposed. To estimate the motions of image sequences, these methods usually have been based on the combination of optical flow equation, affine transform, and iteration. But the compuataional cost of these methods is expensive. This paper presents a fast motion estimation algorithm using a multiple linear regression model to solve the defects of the BMA and the triange-based methods. After describing the basic 2-D triangle-based method, the details of the proposed multiple linear regression model are presented along with the motion estimation results from one standard video sequence, representative of MPEG-4 class A data. The simulationresuls show that in the proposed method, the average PSNR is improved about 1.24 dB in comparison with the BMA method, and the computational cost is reduced about 25% in comparison with the 2-D triangle-based method.

  • PDF

A Motion Editing System for Handling Autonomous Creation of Character Animation

  • Lee, Ji-Hong;Kim, In-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.117.1-117
    • /
    • 2001
  • A motion handling technique that transforms existing animation motion data to a mathematically well-defined form. The transformed data can be utilized in any kind of autonomous motion creation process that handles such cases as changed environment, structure (kinematic / dynamic) modification, or changed constraints. To overcome the computational burden of traditional spacetime optimization, we divide full motion data frame into several parts, and we applied the transformation technique to each part using an optimizing tool(CFSQP). To show Ire feasibility of the proposed method, a comparison study results with traditional technique is included.

  • PDF

선형변이 차동변압기를 이용한 왕복운동 계측기법 (An Alternating Motion Technique Using Linear Variable Differential Transformers)

  • 최주호;김윤겸
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.1073-1077
    • /
    • 1996
  • This paper presents a recoil and counter recoil(R&CR) motion measurement method using linear variable differential transformers(LVDT). The output of a LVDT is obtained from the differential voltage of the 2nd transformers. As a sensor core is attached at the motion body, the output is directly proportional to the core motion. Displacement, velocity and acceleration are measure from the core length. With a comparison between the measurement result and the known value which is obtained by the precision steel tape, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

선형이 EPSO의 운동특성에 미치는 영향 (Effect of Hull Form on Motion Characteristics of EPSO)

  • 원윤상;심달진;김진기;유우준;장종희
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.266-269
    • /
    • 2001
  • This paper describes the effect of hull form on motion characteristics of FPSO. The purpose of the present study is to investigate seakeeping performance of ship type FPSO in comparison with those of barge type FPSO. Model test result shows that the barge type FPSO is better in heave and pitch motion, while the ship type FPSO is superior in roll motion.

  • PDF

적응적 신축 움직임 추정 방법 (Adaptive Zoom Motion Estimation Method)

  • 장원석;권오준;권순각
    • 한국멀티미디어학회논문지
    • /
    • 제17권8호
    • /
    • pp.915-922
    • /
    • 2014
  • We propose an adaptive zoom motion estimation method where a picture is divided into two areas based on the distance information with a depth camera : the one is object area and the other is background area. In the proposed method, the zoom motion is only applied to the object area except the background area. Further, the block size of motion estimation for the object area is set to smaller than that of background area. This adaptive zoom motion estimation method can be reduced at the complexity of motion estimation and can be improved at the motion estimation performance by reducing the block size of the object area in comparison with the conventional zoom motion estimation method. Based on the simulation results, the proposed method is compared with the conventional methods in terms of motion estimation accuracy and computational complexity.

상부등뼈도수교정과 목뼈부위안정화운동이 만성 목뼈부위 기계학적 통증 환자의 관절가동범위와 장애지수에 미치는 효과 비교 (Comparison of between Upper Thoracic Manipulation and Cervical Stability Training on Range of Motion and Neck Disability in Patients with Chronic Mechanical Neck Pain)

  • 이병권;양진모;강경환
    • 대한물리의학회지
    • /
    • 제10권2호
    • /
    • pp.35-45
    • /
    • 2015
  • PURPOSE: The aim of this study is to investigate how upper thoracic manipulation and cervical stability training affects cervical range of motion and neck disability index of patients with chronic mechanical neck pain. METHODS: 30 patients with chronic mechanical neck pain, and randomly divided into the upper thoracic manipulation and the cervical stability training group. Upper thoracic manipulation group was conducted to the upper thoracic manipulation, and cervical stability training was conducted to the cervical stability training. Intervention period was 6 weeks, and 3 sessions, each of which was run for 5~10 minutes. The subjects were measured neck range of motion before and after intervention by electro-goniometer. Neck disability index was used to measure neck disability index Korean version. RESULTS: Comparison within groups, there were significant difference in neck range of motion before and after intervention, and Neck disability index significantly reduced in the cervical stability training group. The comparison between groups, there were no significant difference in neck range of motion and neck disability index. CONCLUSION: Upper thoracic manipulation and cervical stability training to the patients with chronic neck pain was helpful to improve neck range of motion and cervical stability training was helpful to improve neck disability index.

용량성 전극의 동잡음 측정 장치 연구 (A Study on Measurement of Capacitive Electrode Motion Artifact)

  • 임용규
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권3호
    • /
    • pp.137-141
    • /
    • 2017
  • The indirect-contact bio-electric measurements using capacitive electrodes show large motion artifacts in comparison with conventional direct-contact measurements. It is necessary to measure the motion artifacts quantitatively, for the researches of reducing the motion artifacts. In this study, a device for quantitative measurement of motion artifacts was built. Using the device, an electrode was rubbed against some cloth(cotton) and the voltage variation of the electrode was measured as motion artifact in several environmental conditions(temperature and relative humidity). The measured waveforms agreed with that expected by the triboelectricity and the prior observations of the motion artifacts. Therefore, the results demonstrated the usability of the measurement system built in this study. The measurement system will be a great contribution to future research for reducing motion artifact.