• 제목/요약/키워드: Motion Artifacts

검색결과 178건 처리시간 0.038초

Generalized Motion Artifacts Index Usable for Various Patterns of Video Images

  • Oka, Koichi;Kitagishi, Keiko;Enami, Yoshi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.129-133
    • /
    • 2005
  • An integrated pattern profile distortion is newly proposed to analyze various two-dimensional test patterns. The unit is converted to a time to make parameters comparable for various types of displays. In addition, this can be compared with that of extended blur edge width in time scale, which has been reported.

  • PDF

칼만 필터를 이용한 흉곽 임피던스법 기반의 호흡 신호 계측시스템 개발 (Development of Pneumography Impedance Based Respiration Measurement System Using Kalman Filter)

  • 남은혜;최창현;김용주;신동렬
    • Journal of Biosystems Engineering
    • /
    • 제33권5호
    • /
    • pp.326-332
    • /
    • 2008
  • A respiration measurement system for vital signs was developed. Respiration signals were measured, processed, and analyzed. Four electrodes, attached on the surface of the skin, were used to monitor respiration signals by impedance pneumography. The measured signals were amplified, detrended, filtered, and transferred toan embedded module. The Kalman filter was used to remove motion artifact from the respiration signals. Experiments were conducted at stable condition and walking condition to evaluate the performance of the system. Respiration rates of five males and five females were measured and analyzed at each condition. The referenced respiration signal was determined by temperature of nose surroundings. The results showed that the respiration rates at the walking condition had more motion artifacts than the stable condition. The accuracies of the respiration measurement system with Kalman filter were found as 96% at the stable condition and 95% at the walking condition. The results showed that the Kalman filter was an effective tool to remove the motion artifact from the respiration signal.

A LOCALIZED GLOBAL DEFORMATION MODEL TO TRACK MYOCARDIAL MOTION USING ECHOCARDIOGRAPHY

  • Ahn, Chi Young
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제18권2호
    • /
    • pp.181-192
    • /
    • 2014
  • In this paper, we propose a robust real-time myocardial border tracking algorithm for echocardiography. Commonly, after an initial contour of LV border is traced at one or two frame from the entire cardiac cycle, LV contour tracking is performed over the remaining frames. Among a variety of tracking techniques, optical flow method is the most widely used for motion estimation of moving objects. However, when echocardiography data is heavily corrupted in some local regions, the errors bring the tracking point out of the endocardial border, resulting in distorted LV contours. This shape distortion often occurs in practice since the data acquisition is affected by ultrasound artifacts, dropout or shadowing phenomena of cardiac walls. The proposed method deals with this shape distortion problem and reflects the motion realistic LV shape by applying global deformation modeled as affine transform partitively to the contour. We partition the tracking points on the contour into a few groups and determine each affine transform governing the motion of the partitioned contour points. To compute the coefficients of each affine transform, we use the least squares method with equality constraints that are given by the relationship between the coefficients and a few contour points showing good tracking results. Many real experiments show that the proposed method supports better performance than existing methods.

이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석 (A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans)

  • 김태호;윤제웅;강성희;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제23권3호
    • /
    • pp.145-153
    • /
    • 2012
  • 본 연구에서는 호흡에 의한 표적의 움직임 모사가 가능한 팬톰을 이용, 나선형 4DCT 영상에서 발생되는 위상 내 모션 아티팩트(residual motion artifact)의 경향을 분석했으며, 그 특성 및 원인 분석을 위한 이론적 모델을 제시하였다. 표적의 움직임은 SI 방향의 1차원 사인파형을 적용하였으며, 주기는 4s로 고정, 진폭은 10, 20, 30 mm로 변화를 주었다. 표적의 움직임과 동조를 이루는 호흡신호를 얻은 후 이를 기반으로 최대흡기(Inhale peak, 0%)로부터 10% 위상간격(phase bin)으로 재분류하여 총 10개의 4DCT 영상을 재구성하였다. 각각의 진폭(10, 20, 30 mm)별로 획득된 총 30 사례의 영상은 RTP 시스템(CorePLAN, SC&J)에서 분석을 수행하였으며, 경계설정 시 오류를 줄이기 위해 contour window를 고정 값으로 설정한 후 SI 방향의 표적 지름변화를 측정하여 왜곡 정도를 평가 하였다. 각 위상 별 표적의 지름 변화를 측정한 결과 일정한 변화 경향을 확인할 수 있었다. 3 사례(10, 20, 30 mm) 모두 50% 위상(phase) 영상에서 비교적 작은 지름 변화가 관찰 되었는데 10 mm 진폭에서는 정지 영상 대비 변화가 없었고, 20 mm 진폭에서는 0.1 cm (5%)의 변화, 30 mm 진폭에서는 0.1 cm (5%) 변화를 확인할 수 있었다. 반면 30% 위상(phase) 또는 80% 위상 영상에서는 다른 위상 영상에 비해 표적 지름의 변화가 비교적 크게 나타남을 확인할 수 있었다. 10 mm 진폭에서는 정지 영상대비 최대 0.2 cm (10%) 지름 변화가 나타났고 20 mm 진폭에서는 최대 0.7 cm (35%)의 변화, 30 mm 진폭에서는 최대 0.9 cm (45%)의 지름 변화가 나타났다. 이상의 실측결과를 이론모델의 시뮬레이션 결과와 비교해 봤을 때 변화의 양적인 측면에서는 다소 차이가 발생되었지만 변화의 경향성을 확인하는 측면에서는 의미 있는 결과를 얻을 수 있었다. 본 연구의 결과를 통해 규칙적인 1차원 표적 움직임(sine motion)이 적용된 나선형 4DCT 영상에서도 위상 내 움직임에 의한 표적 지름변화가 발생될 수 있음을 확인했고 각 위상(phase)에서의 영상왜곡 정도가 위상 내 움직임의 속도에 비례함을 증명할 수 있었다. 또한 이상의 실측 결과를 이론모델에 적용하여 분석함으로써 위상 내 모션 아티팩트(residual motion artifact)의 발생원인 및 경향성 분석에 직관적 이해를 도울 수 있었고 이론모델에 기초한 분석 프로그램을 개발하여 특정 CT 파라미터(parameter) 상에서 영상왜곡을 줄이기 위한 최적의 위상(phase) 선택에 도움을 줄 수 있었다.

Towards Routine Clinical Use of Radial Stack-of-Stars 3D Gradient-Echo Sequences for Reducing Motion Sensitivity

  • Block, Kai Tobias;Chandarana, Hersh;Milla, Sarah;Bruno, Mary;Mulholland, Tom;Fatterpekar, Girish;Hagiwara, Mari;Grimm, Robert;Geppert, Christian;Kiefer, Berthold;Sodickson, Daniel K.
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권2호
    • /
    • pp.87-106
    • /
    • 2014
  • Purpose : To describe how a robust implementation of a radial 3D gradient-echo sequence with stack-of-stars sampling can be achieved, to review the imaging properties of radial acquisitions, and to share the experience from more than 5000 clinical patient scans. Materials and Methods: A radial stack-of-stars sequence was implemented and installed on 9 clinical MR systems operating at 1.5 and 3 Tesla. Protocols were designed for various applications in which motion artifacts frequently pose a problem with conventional Cartesian techniques. Radial scans were added to routine examinations without selection of specific patient cohorts. Results: Radial acquisitions show significantly lower sensitivity to motion and allow examinations during free breathing. Elimination of breath-holding reduces failure rates for non-compliant patients and enables imaging at higher resolution. Residual artifacts appear as streaks, which are easy to identify and rarely obscure diagnostic information. The improved robustness comes at the expense of longer scan durations, the requirement for fat suppression, and the nonexistence of a time-to-center value. Care needs to be taken during the configuration of receive coils. Conclusion: Routine clinical use of radial stack-of-stars sequences is feasible with current MR systems and may serve as substitute for conventional fat-suppressed T1-weighted protocols in applications where motion is likely to degrade the image quality.

Advanced Frame Rate Conversion without Halo and judder effect for 120Hz LCD Displays

  • Lim, Kyoung-Won;Kim, Han-Soo;Noh, Hyun-Chul;Shin, Hyun-Chul;Jung, Woo-Chul;Koo, Gun-Jae;Park, Ryuk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1397-1400
    • /
    • 2008
  • Frame rate conversion became key technology due to recent advances in LCD panel refresh rates. Although many FRC algorithms have been developed and applied for LCD TV sets, they still suffer from well-known halo artifact. This paper discusses about the artifacts and method to handle them.

  • PDF

Motion Artifact Elimination Technology for LCD Monitors; Advanced DCC

  • Lee, Seung-Woo;Kwon, Su-Hyun;Kim, Myeong-Su;Souk, Jun;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.659-662
    • /
    • 2005
  • This paper presents a new technology, Advanced Dynamic Capacitance Compensation (A-DCC), for improved dynamic performance of LCD monitors. Conventional LCD monitors suffer from certain specific artifacts, such as wire-frame flicker and line dimming, which are not an issue for the simpler motion images found in television content. A-DCC addresses these more challenging monitor cases through an advanced architecture which analyzes multi-frame data and applies more comprehensive lookup table corrections according to the specific frame sequence.

  • PDF

무구속 전극을 이용한 의자형 심전도 모니터링 시스템의 구현 및 평가 (Implementation and Evaluation of Chair-type ECG Monitoring System using Unconstraint Electrode)

  • 노윤홍;정도운
    • 융합신호처리학회논문지
    • /
    • 제16권2호
    • /
    • pp.56-62
    • /
    • 2015
  • 본 연구에서는 현대인들의 일상생활 중 대부분의 시간을 보내는 좌식생활 중에 무구속적으로 장시간 심장활동상태를 모니터링하기 위한 의자형 무구속 심전도 모니터링 시스템을 설계 및 구현하였다. 구현된 시스템은 옷을 입은 상태에서도 측정이 가능하며, 동잡음에도 비교적 강한 장점을 가진다. 이를 위하여 의자의 등받이 부분에 무구속 전극을 배치하였으며, 미세한 생체신호를 증폭하고, 측정 시 발생 할 수 있는 동잡음 및 기저선의 변화, 상용전원에 의한 전원잡음을 제거하기 위하여 증폭기 및 필터를 설계하였다. 또한 제어부와 무선전송부를 구현하여 아날로그 신호를 디지털 신호로 변환하고 생체신호를 PC와 스마트폰으로 전송함으로써 일상생활 중 지속적인 심장활동 상태의 모니터링이 가능하다. 구현된 시스템의 성능을 평가하기 위하여 Ag/AgCl 전극을 사용한 시스템과 비교 실험을 수행하였으며, 실험 결과 구현된 시스템의 무구속적으로 심장활동 상태 모니터링이 가능함을 확인하였다.

영역분할 및 예측을 통한 객체기반 스테레오 동영상 부호화 (Object-based Stereoscopic Video Coding Using Image Segmentation and Prediction)

  • 권순규;배태면;한규필;정의윤;하영호
    • 한국통신학회논문지
    • /
    • 제24권12B호
    • /
    • pp.2349-2358
    • /
    • 1999
  • 본 논문에서는 스테레오 동영상의 객체기반 부호화 기법을 제안하였다. 스테레오 영상열의 정보량을 줄이면서 블록화 현상이나 모스키토 현상과 같은 블록정합 기반 방법의 예측오차를 줄이기 위해서는 객체기반 부호화 기법이 필요하다. 객체기반 방법에서는 부호화에 적절한 객체를 추출하기가 어렵고, 추출된 객체에 대해서 프레임이 지남에 따라 갱신해 주어야 하는 문제점이 발생한다. 이를 개선하기 위해서 제안된 방법에서는 전처리, 객체추출, 객체갱신 과정을 사용하였다. 전처리 과정에서는 움직임과 변이 예측의 신뢰성이 낮은 영역을 비객체영역으로 분할하여 부정확한 객체의 추출을 방지하였다. 객체추출 과정에서는 좌영상의 예측을 향상시키기 위해 기존의 움직임과 밝기값을 고려하는 영상분할법에 변이를 추가함으로서 객체기반 부호화에 적합한 객체를 추출하였다. 그리고 객체갱신 과정에서는 새로운 객체의 추출, 객체분할, 객체 병합을 적용하여 누적 오차를 줄였다.

  • PDF

적응 노치필터와 퍼지추론 시스템을 이용한 광용적 맥파 신호의 동잡음 제거 필터 설계 (Design of Filter to Remove Motion Artifacts of Photoplethysmography Signal Using Adaptive Notch Filter and Fuzzy Inference system)

  • 이주원;이병로
    • 융합신호처리학회논문지
    • /
    • 제20권1호
    • /
    • pp.45-50
    • /
    • 2019
  • 모바일 헬스케어 디바이스에서 가장 많이 사용되는 PPG 신호는 디바이스 사용자의 움직임의 영향에 따라 심박수 측정의 정확도가 떨어진다. 그 이유는 사용자의 동잡음의 주파수 대역이 PPG 신호의 주파수 대역과 겹쳐 있기 때문이다. 이러한 동잡음을 제거하기 위해 주파수 분석법, 가속도 센서 적용 등의 다양한 방법들이 연구되어 우수한 성능을 제시하였지만, 저가의 헬스케어 디바이스에 이들 필터법을 적용함에 있어 많은 연산처리 시간과 센서 가격 측면 때문에 적용하기가 어렵다. 이러한 문제점을 해결하기 위해 본 연구에서는 실시간으로 보다 정확한 심박수를 추출하기 위해 퍼지추론 시스템과 적응노치 필터를 이용한 PPG 신호처리 기법을 제안하고 그 성능을 평가하였다. 그 결과, 기존의 방법보다 우수한 결과를 보였으며, 이 결과를 토대로 제안된 방법을 모바일 헬스케어 디바이스 설계에 적용한다면 실시간으로 보다 정확한 심박수 측정이 가능할 것이다.