• Title/Summary/Keyword: Moon: reflection

Search Result 158, Processing Time 0.032 seconds

Measurement of Refractive Index of Solid Medium by Critical Angle Method When Air Gap is Present

  • Lim, Hwan-Hong;Kwon, Moon-Soo;Choi, Hee-Joo;Kim, Byoung-Joo;Cha, Myoung-Sik
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.210-214
    • /
    • 2008
  • A critical angle method was used to measure the index of refraction of a solid medium when an air gap between the prism and the medium is present. The gap effect was analyzed both numerically and experimentally. Since the total internal reflection is severely disturbed by the large gap, determination of the critical angle and the resulting refractive index becomes ambiguous and inaccurate. By using an index matching fluid, we could determine the index of refraction with an uncertainty of ${\pm}2{\times}1^{-3}$ even when the gap is as large as 1 ${\mu}m$.

Design and Construction of the Cylindrical Slit Type Shore Structures

  • Lee, Joong-Woo;Nam, Ki-Dae;Park, Sang-Gill;Kim, Sug-Moon;Kang, Seok-Jin
    • Journal of Navigation and Port Research
    • /
    • v.33 no.9
    • /
    • pp.645-651
    • /
    • 2009
  • In this study, a series of laboratory experiments were carried out to investigate the weak reflection of regular and random water waves over a train of protruded permeable shore structures. A cylindrical slit type breakwater and the alternatives are employed and compared for reflecting and transmitting capabilities of incident waves including wave forces. A series of random waves were generated by using the Bretschneider-Mitsuyasu frequency and directional spectrum. Measured spectrum of irregular waves without breakwaters is verified by comparing with those of the input waves generated. Weak reflection is occurred at the breakwater center of the peak frequency. If the row of breakwaters is fixed at three layers and the relative height of breakwater is fixed at 0.6, around 45% of incident wave energy is reflected to offshore. It is also found that the transmission of directional random waves increases as the maximum frequency parameter increases. A very good agreement is observed. Reflection coefficients of permeable submerged breakwaters are less than those of impermeable breakwaters. The upside-down L shape is recommended for a small fishery harbor mooring in terms of reflecting capability and of practical application. The final design was applied to the wharf of a small beach of Seolly, near Namhae at the southeast coast of Korea.

Case-based Learning through Home Care Nursing Specialists' Critical Reflection: Application with Patients Using Home Mechanical Ventilator (가정전문간호사의 비판적 성찰을 통한 사례기반 학습: 가정용 인공호흡기 적용대상자)

  • Park, Hak Young;Hwang, Moon Sook;Kim, Yeon Hee
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.25 no.3
    • /
    • pp.153-163
    • /
    • 2018
  • Purpose: This study is know the home care nursing specialists' copying method for life-threatening emergency situation occurred while changing the tracheotomy tube in the patient's home through case-based learning. Methods: Two cases were analyzed using structured critical reflection while changing the tracheal tube. In the first case, the patient presented with dyspnea, cyanosis, and low oxygen saturation when connected to home mechanical ventilator after replacement of the tracheotomy tube. In the second case, replacement of the tracheal tube was difficult due to a narrowed airway from proliferated granulation tissue. Results: From the case-based learning. using a critical reflection instrument, home care nursing specialists indicated that it was important to explain the possibility of danger to the client and that nurses must check the operation of the ambu-bag to prepare for an emergency when replacing a tracheotomy tube. Moreover, they stated a need for two nurses during client visits when there is the possibility of an emergency. Conclusion: Case-based learning through critical reflection provides actual practice-focused knowledge that is helpful to home care nurse specialists who face emergency situations in a restricted environment. Therefore, we hope that home care nursing specialists will use this method to strengthen their professional knowledge.

Influence of air pressure, temperature, humidity and CO$_{2}$ concentration on optical phase changes in thin films

  • Kim, Moon-Hwan;Tachikawa, Yoshihiko;Ogita, Eiji;Ueda, Toshitsugu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.799-804
    • /
    • 1989
  • A new method for measuring optical phase changes of reflection beam from optical mirror is proposed. The optical phase change is liable to change with varying atmosphere conditions. This optical phase changes are measured against air pressure, temperature, humidity and CO$\_$2/ concentration variations. It is clarified that the optical phase changes are most effected by humidity change.

  • PDF

A study on Effective Feature Parameters Comparison for Speaker Recognition (화자인식에 효과적인 특징벡터에 관한 비교연구)

  • Park TaeSun;Kim Sang-Jin;Kwang Moon;Hahn Minsoo
    • Proceedings of the KSPS conference
    • /
    • 2003.05a
    • /
    • pp.145-148
    • /
    • 2003
  • In this paper, we carried out comparative study about various feature parameters for the effective speaker recognition such as LPC, LPCC, MFCC, Log Area Ratio, Reflection Coefficients, Inverse Sine, and Delta Parameter. We also adopted cepstral liftering and cepstral mean subtraction methods to check their usefulness. Our recognition system is HMM based one with 4 connected-Korean-digit speech database. Various experimental results will help to select the most effective parameter for speaker recognition.

  • PDF

Improvement in the Contrast Ratio of PDPs in the Bright Room using Pigmented Phosphors with Effective Reflectance

  • Moon, E.A.;Moon, T.H.;Lee, H.C.;Hong, G.Y.;Kim, J.S.;Ryu, B.G.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.598-600
    • /
    • 2008
  • In order to improve the contrast ratio of PDPs in the bright room, we decreased the panel reflection by coating phosphors with pigments. In this work, we investigated the panel reflectance with various sizes of the blue pigments and obtained good results by reducing the size of the pigment properly.

  • PDF

Absorption Properties of Thin Permalloy-Rubber Absorbers in Mobile Telecommunication Frequency Bands (Permalloy를 이용한 이동통신주파수 대역용 박형 전파흡수체의 제조 및 특성 연구)

  • Kim, Moon-Suk;Min, Eui-Hong;Koh, Jae-Gui
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.3
    • /
    • pp.115-119
    • /
    • 2008
  • The raw materials of permalloy were processed the ball-mill for 30 hours and the shape of permalloy particles was changed from sphere to flake type, which was observed using scanning electron microscope. The complex permittivity and permeability spectra and reflection loss of permalloy-rubber composite was measured using Network Analyzer in order to investigate the relationship between the microwave absorption and the material constants. The flake type permalloy-rubber composite showed high reflection loss, which was due to the high complex permittivity and permeability. Also, the matching frequency shifted toward lower frequency range with microwave absorber thickness, and the maximum reflection loss of -6.1 dB was observed in $1.65\;GHz{\sim}1.86\;GHz$ for a 1.3 mm thickness.

Corrosion and Photo-Reflection Behavior of Aluminum and Stainless Steel During Immersion Test in Salt Solution (3 wt% NaCl 수용액에서 알루미늄과 스테인리스강의 부식에 따른 광 반사 거동)

  • Cho, Soo Yeon;Na, Hyeon Gyu;Cho, Hye Ri;Moon, Jong Ju;Ahn, Tae-Jung;Jang, HeeJin
    • Corrosion Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.109-114
    • /
    • 2020
  • The photo-reflectance of aluminum and AISI 304 stainless steel during cyclic immersion test in 3 wt% NaCl solution was examined in this study. Overall, corrosion was not recognized by a visual inspection or weight measurement up to 310 h. When evaluated, it was noted that the roughness of the specimens did not change significantly. However, localized corrosion, which is located at the vicinity of intermetallic precipitation of aluminum or at the grain boundary of stainless steel, was confirmed by the use of an optical microscope and scanning electron microscopy after tens of hours of utilizing the corrosion test. In this respect, an increase of the peak intensity for metallic Al after 90 h of test, and for metallic Fe after 153 h was detected from the X-ray photoelectron spectra. In this context, it was shown that from the photo-reflectance spectra, the reflection of the visible light from the tested samples was changed noticeably over the test duration. As a result, the intensity of reflected light was decreased up to 90 h ~ 153 h, and thereafter was shown to increase higher than the initial intensity before the corrosion test.

FTIR and Moisture Effects on Optical Information Transfer at Interface of Air and Glass (공기-유리 계면에서 광학정보 전달에 미치는 불완전 반사 및 수분 효과)

  • Han, Won Heum;Han, Ji Heum;Kim, Jee Hyen;Jung, Hyung Sik;Lee, Moon Ho
    • Journal of Adhesion and Interface
    • /
    • v.13 no.2
    • /
    • pp.73-84
    • /
    • 2012
  • The transfer mechanism of optical information at the interface of air and glass (the air-glass IF) has been investigated by thoroughly fulfilling the theoretical and experimental analyses regarding the FTIR (Frustrated Total Internal Reflection) and moisture effects on the fingerprint onto a glass cup with water. As for the fingerprint onto a glass cup with water its image was observed to be very vivid, which turned out to be due to the difference between the two light intensities reflected on the air-glass IF and the wet fingerprint ridge by manipulating the optical theories such as Fresnel relation, Snell's law, FTIR, GT (general transmission) and so on. In addition, the experimental inspection for FTIR and moisture effects on the fingerprint image also evidenced the fact that the vivid fingerprint image originated from the moisture effect rather than the FTIR phenomenon.