• Title/Summary/Keyword: Monte Carlo simulation code

Search Result 270, Processing Time 0.026 seconds

Demonstration of the Effectiveness of Monte Carlo-Based Data Sets with the Simplified Approach for Shielding Design of a Laboratory with the Therapeutic Level Proton Beam

  • Lai, Bo-Lun;Chang, Szu-Li;Sheu, Rong-Jiun
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.50-57
    • /
    • 2022
  • Background: There are several proton therapy facilities in operation or planned in Taiwan, and these facilities are anticipated to not only treat cancer but also provide beam services to the industry or academia. The simplified approach based on the Monte Carlo-based data sets (source terms and attenuation lengths) with the point-source line-of-sight approximation is friendly in the design stage of the proton therapy facilities because it is intuitive and easy to use. The purpose of this study is to expand the Monte Carlo-based data sets to allow the simplified approach to cover the application of proton beams more widely. Materials and Methods: In this work, the MCNP6 Monte Carlo code was used in three simulations to achieve the purpose, including the neutron yield calculation, Monte Carlo-based data sets generation, and dose assessment in simple cases to demonstrate the effectiveness of the generated data sets. Results and Discussion: The consistent comparison of the simplified approach and Monte Carlo simulation results show the effectiveness and advantage of applying the data set to a quick shielding design and conservative dose assessment for proton therapy facilities. Conclusion: This study has expanded the existing Monte Carlo-based data set to allow the simplified approach method to be used for dose assessment or shielding design for beam services in proton therapy facilities. It should be noted that the default model of the MCNP6 is no longer the Bertini model but the CEM (cascade-exciton model), therefore, the results of the simplified approach will be more conservative when it was used to do the double confirmation of the final shielding design.

PN code acquisition for the N-path RAKE receiver in the DS/CDMA systems (DS/CDMA 이동통신 시스템의 N-경로 RAKE 수신기를 위한 PN 코드동기)

  • 이한섭;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1510-1521
    • /
    • 1996
  • This paper presents acquisition algorithm and an improved detection technique for the DS/CDMA (direction sequence code division multiple access) RAKE receiver in multipath fading channel. The DS/CDMA systems use the RAKE receiver, an accurate code acquisition is required for the RAKE branches. The algorithmis able to findthe pseudonoise (PN) code delay estimates for the RAKE branches in a multipath fading channel. In this paper a numerical method and computer simulation simulation have been developed for the acquisition system. The detection probability and mean acquisition time are investigated asa performance measure of the system using the Monte Carlo method. And also in order to analyze the effect of the acquisition on the RAKE receiver this paper bring out the effect of integration time, doppler frequency, processing gain and the number of users on the acquired code phase.

  • PDF

A Far-UV Study in Taurus-Auriga-Perseus(TPA) Complex

  • Lim, Tae-Ho;Min, Kyung-Wook;Seon, Kwang-Il
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.80.2-80.2
    • /
    • 2012
  • We firstly present the unified Far-UV continuum map of the Taurus-Auriga-Perseus (TPA) complex, one of the largest local associations of dark cloud located in (l, b)=([152,180], [-28, 0]), by merging both FIMS and GALEX. The FUV continuum map shows that dust extinction correlate well with the FUV around the complex. It says strong absorption in the dense Taurus cloud and Auriga cloud. Although the column density of Perseus and California cloud is similar to Taurus' and Auriga's, Perseus and California cloud do not show strong absorption in FUV because they are more distant than Taurus and Auriga cloud. We also present the dust scattering simulation based on Monte Carlo Radiative Transfer technique. Through the result of Monte-Carlo dust scattering simulation and comparing the result with FIMS-GALEX unified map we gain deeper understanding related to the spatial dust distribution of TPA region. As a preliminary result of the simulation we present the most probable front face, thickness, albedo, and asymmetry factor in this region, respectively. Through this work we can show a certain inclination of the spatial dust distribution. During this study we have developed the FUV dust scattering simulation code using Monte-Carlo method. We expect that it will be generally used to simulate dust scattering in the Galaxy.

  • PDF

Study on the Dynamic Model and Simulation of a Flexible Mechanical Arm Considering its Random Parameters

  • He Bai-Yan;Wang Shu-Xin
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.spc1
    • /
    • pp.265-271
    • /
    • 2005
  • Randomness exists in engineering. Tolerance, assemble-error, environment temperature and wear make the parameters of a mechanical system uncertain. So the behavior or response of the mechanical system is uncertain. In this paper, the uncertain parameters are treated as random variables. So if the probability distribution of a random parameter is known, the simulation of mechanical multibody dynamics can be made by Monte-Carlo method. Thus multibody dynamics simulation results can be obtained in statistics. A new concept called functional reliability is put forward in this paper, which can be defined as the probability of the dynamic parameters(such as position, orientation, velocity, acceleration etc.) of the key parts of a mechanical multibody system belong to their tolerance values. A flexible mechanical arm with random parameters is studied in this paper. The length, width, thickness and density of the flexible arm are treated as random variables and Gaussian distribution is used with given mean and variance. Computer code is developed based on the dynamic model and Monte-Carlo method to simulate the dynamic behavior of the flexible arm. At the same time the end effector's locating reliability is calculated with circular tolerance area. The theory and method presented in this paper are applicable on the dynamics modeling of general multibody systems.

Diagnostic X-ray Spectra Detection by Monte Carlo Simulation (진단용 X-선 스펙트럼의 몬테칼로 전산모사 측정)

  • Baek, Cheol-Ha;Lee, Seung-Jae;Kim, Daehong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.289-295
    • /
    • 2018
  • Most diagnostic devices in the medical field use X-ray sources, which emit energy spectra. In radiological diagnosis, the quantitative and qualitative analyses of X-rays are essential for maintaining the image quality and minimizing the radiation dose to patients. This work aims to obtain the X-ray energy spectra used in diagnostic imaging by Monte Carlo simulation. Various X-ray spectra are simulated using a Monte Carlo simulation tool. These spectra are then compared to the reference data obtained with a tungsten anode spectral model using the interpolating polynomial (TASMIP) code. The X-ray tube voltages used are 50, 60, 80, 100, and 110 kV, respectively. CdTe and a-Se detector are used as the detectors for obtaining the X-ray spectra. Simulation results demonstrate that the various X-ray spectra are well matched with the reference data. Based on the simulation results, an appropriate X-ray spectrum, in accordance with the tube voltage, can be selected when generating an image for diagnostic imaging. The dose to be delivered to the patient can be predicted prior to examination in the diagnostic field.

Understanding Phytosanitary Irradiation Treatment of Pineapple Using Monte Carlo Simulation

  • Kim, Jongsoon;Kwon, Soon-Hong;Chung, Sung-Won;Kwon, Soon-Goo;Park, Jong-Min;Choi, Won-Sik
    • Journal of Biosystems Engineering
    • /
    • v.38 no.2
    • /
    • pp.87-94
    • /
    • 2013
  • Purpose: Pineapple is now the third most important tropical fruit in world production after banana and citrus. Phytosanitary irradiation is recognized as a promising alternative treatment to chemical fumigation. However, most of the phytosanitary irradiation studies have dealt with physiochemical properties and its efficacy. Accurate dose calculation is crucial for ensuring proper process control in phytosanitary irradiation. The objective of this study was to optimize phytosanitary irradiation treatment of pineapple in various radiation sources using Monte Carlo simulation. Methods: 3-D geometry and component densities of the pineapple, extracted from CT scan data, were entered into a radiation transport Monte Carlo code (MCNP5) to obtain simulated dose distribution. Radiation energy used for simulation were 2 MeV (low-energy) and 10 MeV (high-energy) for electron beams, 1.25 MeV for gamma-rays, and 5 MeV for X-rays. Results: For low-energy electron beam simulation, electrons penetrated up to 0.75 cm from the pineapple skin, which is good for controlling insect eggs laid just below the fruit surface. For high-energy electron beam simulation, electrons penetrated up to 4.5 cm and the irradiation area occupied 60.2% of the whole area at single-side irradiation and 90.6% at double-side irradiation. For a single-side only gamma- and X-ray source simulation, the entire pineapple was irradiated and dose uniformity ratios (Dmax/Dmin) were 2.23 and 2.19, respectively. Even though both sources had all greater penetrating capability, the X-ray treatment is safer and the gamma-ray treatment is more widely used due to their availability. Conclusions: These results are invaluable for optimizing phytosanitary irradiation treatment planning of pineapple.

Light Collection Efficiency of Large-volume Plastic Scintillator for Radiation Portal Monitor (방사선 포털 모니터용 대용적 플라스틱 섬광체 내부 빛 수집 효율 평가)

  • Lee, Jin Hyung;Kim, Jong Bum
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.157-165
    • /
    • 2017
  • In this paper, we calculate the light photons collection efficiency of large-volume plastic scintillation detector mainly used for radiation portal monitor (RPM). A Monte Carlo light photon transport code, DETECT2000, were used to quantitatively evaluate light collection efficiency of plastic scintillation detector. DETECT2000 calculated the placement of light collection efficiency based on the energy spectrum. We calculated the light collection efficiency relative to the position of the energy spectrum that proportional to the placement of the source. The $850{\times}285{\times}65mm^3$ size of polyvinyl toluene (PVT) scintillator was used for measurements. Through DETECT2000 simulation, the light collection efficiency of $5{\times}5$ arrays were calculated and verification was performed by comparing with experimentally measured. And then, the corrected MCNP simulation by applying the light collection efficiency in $21{\times}13$ arrays was compared and analyzed. Comparing the Monte Carlo simulation with measured results, it shows an average difference of 10.1% in $5{\times}5$ arrays. Particularly, about twice of the difference was found in the edge of first column, which coupled with PMT. In whole $5{\times}5$ array, the overall ratio was the same except for the first column. And then comparing the energy spectra of the $21{\times}13$ array with and without the light collection efficiency, it shows a difference of 6.69% in Compton edge area. The DETECT2000 based light collection efficiency simulation showed well agreement with the point source experiment. And comparing with measured energy spectra, we could compare the differences according to whether or not the light collection efficiency was applied. As a results, it is possible to increase the accuracy and reliability of Monte Carlo simulation results by pre-calculating the light collection efficiency according to the PVT geometry by using the DETECT2000.

Evaluation of Absorbed Dose for the Right Lung and Surrounding Organs of the Computational Human Phantom in Brachytherapy by Monte Carlo Simulation (근접방사선치료 시 몬테카를로 전산모사를 이용한 인체전산팬텀의 우측 폐와 주변 장기 선량평가)

  • Lee, Jun-Seong;Kim, Yang-Soo;Kim, Min-Gul;Kim, Jung-Soo;Lee, Sun-Young
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.443-451
    • /
    • 2020
  • This study is to evaluate absorbed dose from right lung for brachytherapy and to estimate the effects of tissue heterogeneities on dose distribution for Iridium-192 source using Monte Carlo simulation. The study employed Geant4 code as Monte Carlo simulation to calculate the dosimetry parameters. The dose distribution of Iridium-192 source in solid water equivalent phantom including aluminium plate or steel plate inserted was calculated and compared with the measured dose by the ion chamber at various distances. And the simulation was used to evaluate the dose of gamma radiation absorbed in the lung organ and other organs around it. The dose distribution embedded in right lung was calculated due to the presence of heart, thymus, spine, stomach as well as left lung. The geometry of the human body was made up of adult male MIRD type of the computational human phantom. The dosimetric characteristics obtained for aluminium plate inserted were in good agreement with experimental results within 4%. The simulation results of steel plate inserted agreed well with a maximum difference 2.75%. Target organ considered to receive a dose of 100%, the surrounding organs were left the left lung of 3.93%, heart of 10.04%, thymus of 11.19%, spine of 12.64% and stomach of 0.95%. When the statistical error is performed for the computational human phantom, the statistical error of value is under 1%.

Coincidence summing correction for a voluminous 152Eu source

  • Yoon, Eun Taek;Kang, Min Young;Kim, In Jung;Sun, Gwang Min;Choi, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1266-1270
    • /
    • 2020
  • A code is developed to correct for the coincidence summing effect in detecting a voluminous gamma source, and this code is applied to a152Eu standard source as a test case. The source is 1000 mL of liquid in a cylindrical shape. To calculate the coincidence summing effect, the cylindrical source is considered as 10(radial) × 8(height) sectional sources. For each sectional source, the peak efficiency and total efficiency are obtained by Monte Carlo simulation at each energy for 10 energies between 50 keV and 2000 keV. The efficiencies of each sector are then expressed as polynomials of gamma energy. To calculate the correction coefficients for the coincidence summing effect, the KORSUM code is used after modification. The magnitudes of correction are 4%-17% for the standard 152Eu source measured in this study. The relative deviation of 4.7% before the coincidence correction is reduced to 0.8% after the correction is applied to the efficiency based on the measured gamma line. Hence, this study has shown that a new method has been developed that is applicable for correcting the coincidence effect in a voluminous source, and the method is applied to the measured data of a standard 152Eu cylinder source.

Monte Carlo simulations of chromium target under proton irradiation of 17.9, 22.3 MeV

  • Kara, A.;Yilmaz, A.;Yigit, M.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3158-3163
    • /
    • 2021
  • Chromium material is commonly used for fusion plasma facing applications because of the low neutron activation property. The Monte Carlo method is one of the useful ways to investigate the ion-target interactions. In this study, Chromium target irradiated by protons was investigated using Monte Carlo based simulation tools. In this context, the calculations of radiation damage on Chromium material irradiated with protons at 17.9 and 22.3 MeV energies were carried out using GEANT4 and SRIM codes. Besides, the cross sections for proton interaction with Chromium target were calculated by the TALYS 1.9 code using CTM + FGM, BSFGM, and GSFM level densities. As a result, GEANT4, SRIM and TALYS 1.9 codes provide a suitable tool for the predictions of radiation damage and cross cross section with proton irradiation.