• Title/Summary/Keyword: Monte Carlo 계산

Search Result 515, Processing Time 0.021 seconds

Evaluation of the Radiochromic Film Dosimetry for a Small Curved Interface (휘어진 경계에서의 좁은 영역에 대한 Radiochromic 필름 도시메트리 평가)

  • Kang, Sei-Kwon;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.234-238
    • /
    • 2012
  • A tumor on the eyelid is often treated using a high-energy electron beam, with a metallic eye shield inserted between the eyelid and the eyeball to preserve the patient's sight. Pretreatment quality assurance of the inner eyelid dose on the metallic shield requires a very small dosimetry tool. For enhanced accuracy, a flexible device fitting the curved interface between the eyelid and the shield is also required. The radiochromic film is the best candidate for this device. To measure the doses along the curved interface and small area, a 3-mm-wide strip of EBT2 film was inserted between the phantom eyelid and the shield. After irradiation with 6 MeV electron beams, the film was evaluated for the dose profile. An acrylic eye shield of the same size as the real eye shield was machined, and CT images free from metal artifacts were obtained. Monte Carlo simulation was performed on the CT images, taking into account eye shield material, such as tungsten, aluminum, and steel. The film-based interface dose distribution agreed with the MC calculation within 2.1%. In the small (millimeter scale) and curved region, radiochromic film dosimetry promises a satisfactory result with easy handling.

Development of Effective ${\gamma}$-ray and ${\beta}$-ray Detection Methods For Low-Level Radioactive Wastes (극저준위 방사성 폐기물을 위한 효율적인 ${\gamma}$-선 및 ${\beta}$-선 측정 방법 개발)

  • Kwak, Sung-Woo;Yeom, Yu-Sun;Kim, Ho-Kyung;Cho, Gyu-Seong;Park, Joo-Wan;Kim, Chang-Lak;Song, Myung-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.393-398
    • /
    • 2001
  • The non-combustible RI wastes disposed of in hospital every year emit ${\gamma}$-ray or ${\beta}$-ray but their activities are very low to the extent of background. Development of more simple methods is needed because the conventional detection methods are so ineffective and complex. In this study, to solve this problem, detection method using efficiency curve for ${\gamma}$-ray emitting radioactive wastes measurement is proposed and experimental detection efficiency equation is also determined through HPGe's standard specimen measurement. For ${\beta}$-emitting radioisotopes detection, new measurement method using detection efficiency estimated by Monte Carlo simulation and SBD measurements is also proposed. According to the results of this paper, the unknown activity of low-level radioactive wastes without LSC requiring the preparation of standard sample and measurement for standard source detection efficiency could be determined efficiently and simply about ${\pm}17%$ in errors by using the theoretical detection efficiency and the SBD measurement result.

  • PDF

Sample thread based real-time BRDF rendering (샘플 쓰레드 기반 실시간 BRDF 렌더링)

  • Kim, Soon-Hyun;Kyung, Min-Ho;Lee, Joo-Haeng
    • Journal of the Korea Computer Graphics Society
    • /
    • v.16 no.3
    • /
    • pp.1-10
    • /
    • 2010
  • In this paper, we propose a novel noiseless method of BRDF rendering on a GPU in real-time. Illumination at a surface point is formulated as an integral of BRDF producted with incident radiance over the hemi-sphere domain. The most popular method to compute the integral is the Monte Carlo method, which needs a large number of samples to achieve good image quality. But, it leads to increase of rendering time. Otherwise, a small number of sample points cause serious image noise. The main contribution of our work is a new importance sampling scheme producing a set of incoming ray samples varying continuously with respect to the eye ray. An incoming ray is importance-based sampled at different latitude angles of the eye ray, and then the ray samples are linearly connected to form a curve, called a thread. These threads give continuously moving incident rays for eye ray change, so they do not make image noise. Since even a small number of threads can achieve a plausible quality and also can be precomputed before rendering, they enable real-time BRDF rendering on the GPU.

The Development of Fixing Equipment of the Unit Module Using the Probability Distribution of Transporting Load (운반하중의 확률분포를 활용한 유닛모듈 운반용 고정장치 개발)

  • Park, Nam-Cheon;Kim, Seok;Kim, Kyoon-Tai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4267-4275
    • /
    • 2015
  • Prefabricated houses are fabricated at the factory for approximately 60 to 80% of the entire construction process, and assembled in the field. In the process of transporting and lifting, internal and external finishes of the unit module are concerned about damages. The purpose of this study is to improve the fixing equipment by analyzing load behavior. The improved fixing equipment would minimize the deformation of internal and external finishes. In order to develop the improved fixing equipment, transporting load on the fixing equipment is analyzed using Monte Carlo simulations, and structural performance is verified by the non-linear finite element analysis. Statistical analysis shows load distribution of unit module is similar with extreme value distribution. Based on the statistical analysis and Monte Carlo simulation, the maximum transporting load is 28.9kN and 95% confidence interval of transporting load is -1.22kN to 9.5kN. The nonlinear structural analysis shows improved fixing equipment is not destructed to the limit load of 35.3kN and withstands the load-bearing in the 95% confidence interval of transporting load.

Improved Scatter Correction for SPECT Images : A Monte Carlo Simulation Study (SPECT 영상 산란보정 개선: 몬테칼로 시뮬레이션 연구)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Son, Hye-Kyung;Lee, Jong-Doo;Jung, Hae-Jo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.163-173
    • /
    • 2005
  • Purpose: Abutted scatter energy windows used for a triple energy window (TEW) method may provide wrong estimation of scatter. This study is to propose an extended TEW (ETEW) method, which doesn't require abutted scatter energy windows and overcomes the shortcomings of TEW method. Materials & Methods: The ETEW is a modification of the TEW which corrects for scatter by using abutted scatter rejection windows, which can overestimate or underestimate scatter. The ETEW is compared to the TEW using Monte Carlo simulated data for point sources as well as hot and cold spheres in a cylindrical water phantom. Various main energy window widths (10 %, 15 % and 20 %) were simulated. Both TEW and ETEW improved image contrast, % recovery coefficients and normalized standard deviation. Results: Both of TEW and ETEW improved image contrast and % recovery coefficients. Estimated scatter components by the TEW were not proportional to the true scatter components over the main energy windows when ones of 10 %, 15 %, and 20 % were simulated. The ETEW linearly estimated scatter components over the width of the main energy windows. Conclusion: We extended the TEW method into the method which could linearly estimate scatter components over the main energy windows.

Analysis of the Dead Layer Thickness effect and HPGe Detector by Penelope Simulation (Penelope Simulation에 의한 불감층 두께 효과 및 HPGe 검출기 분석)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.801-806
    • /
    • 2018
  • Germanium crystals have a dead layer that causes efficiency deterioration because the layer is not useful for detection but strongly weakens the photons. Thus, when the data provided by the manufacturer is used in the detector simulation model, there is a slight difference between the calculated efficiency and the measured efficiency.The shape and dimensions of the high purity germanium (HPGe) detector were determined by CT scans to accurately characterize the shape for the Monte Carlo roll simulation. It is found that the adjustment of the dead layer is a good match with the relative deviation of ${\pm}3%$ between the measurement efficiency and the simulation efficiency at the energy range of 50 - 1500 keV. Simulation data were compared by varying the thickness of the dead layer. The new Monte Carlo simulations were compared with the experimental results to obtain new blank layer thicknesses. The difference in dead layer results for the 1.5 mm thick end cap simulation model in 1.4 and 1.6 mm thick End Cap simulation models was a systematic error due to the accuracy of the end cap dimensions. After considering all errors including statistical errors and systematic errors, the thickness of the detector was calculated as $1.02{\pm}0.14mm$. Therefore, it was confirmed that the increase in the thickness of the dead layer causes the effect to be effected on the efficiency reduction.

Investigation of Tube Voltage Range using Dose Comparison based on Effective Detector Exposure Index in Chest Radiography (흉부 X-ray 검사 시 선량 비교를 활용한 유효 Detector Exposure Index 기반의 적절한 관전압 범위 제안)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.139-145
    • /
    • 2021
  • This study is to confirm the range of tube voltage for Chest X-ray in DR system by comparing with dose area product (DAP) and effective dose in efficient detector exposure index (DEI) range. GE definium 8000 was used to for the phantom study. The range of tube voltage is 60~130 kVp and of mAs is 2.5~40 mAs. The acquired images were classified into efficient DEI groups, then calculated effective dose with DAP by using a PC-Based Monte Carlo Program 2.0. The signal to noise ratio (SNR) was measured at 4 regions, including the thoracic spine, the lung area with the ribs, the lung area without the ribs, and the liver by using Picture Archiving and Communication System. The significance of the group for each tube voltage was verified by performing the kruskal-wallis test and the mann-whitney test as a post-test. When set to 4 groups dependned on the tube voltage, DAP showed significant differences; 60 kVp and 80 kVp, and 60 kVp and 90 kVp (p= 0.034, 0.021). Effective dose exhibited no statistically significant differences from the all of the group (p>0.05). SNR exhibited statistically significant differences from the all of the group in the liver except compared to 80 kVp and 90 kVp (p<0.05). Therefore, high tube voltages of 100 kVp or more need to be reconsidered in terms of patient dose and imaging in order to represent an appropriate chest X-ray image in a digital system.

A Study on the Evaluation of Radiation Safety in Opened-Ceiling-Facilities for Radiography Testing (천장 개방형 RT 사용시설의 방사선 안전성 평가 연구)

  • Sung-Hoe, Heo;Won-Seok, Park;Seung-Uk, Heo;Byung-In, Min
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.741-749
    • /
    • 2022
  • Radiography-Testing that verify the quality of welding structures without destruction are overwhelmingly used in industries, but many safety precautions are required as radiation is used. The workers for Radiography-Testing perform the inspection by moving the Iridium-192 radiation source embedded in the transport container of the gamma-ray irradiator within or outside the facility. The general facility is completely blocked about radiation from the outside with thick concrete, but if it is difficult for worker to handle object of inspection, facilities ceiling can be opened. A general facility may be constructed using a theoretical dose evaluation method because all exterior facilities are blocked, but if the ceiling is open, it is not appropriate to evaluate radiation safety with a simple theoretical calculation method due to the skyshine effect. Therefore, in this study, the radiation safety of the facility was evaluated in the actual field through an ion chamber survey-meter and an accumulated dose-meter called as OSLD, and the actual evaluation environment was modeled and evaluated using the Monte Carlo simulation code as FLUKA. According to the direction of the irradiation, the radiation dose at the facility boundary was difficult to meet the standards set by the regulatory authority, and radiation safety could be secured through additional methods. In addition, it was confirmed that the simulation results using the Iridium-192 source were valid evaluation with the actual measured results.

Closing Analysis of Symmetric Steel Cable-stayed Bridges and Estimation of Construction Error (대칭형 강 사장교의 폐합해석과 시공오차의 예측)

  • Lee, Min Kwon;Lee, Hae Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.55-65
    • /
    • 2006
  • This paper presents the closing analysis of a symmetric steel cable-stayed bridge erected by a free cantilever method. Two independent structural systems are formed before the closing procedure of a bridge is performed, and thus the compatibility conditions for vertical displacement and rotational angle are not satisfied at the closing section without the application of proper sectional forces. Since, however, it is usually impossible to apply sectional forces at the closing section, the compatibility conditions should be satisfied by proper external forces that can be actually applicable to a bridge. Unstrained lengths of selected cables and the pull-up force of a derrick crane are adjusted to satisfy nonlinear compatibility conditions, which are solved iteratively by the Newton-Raphson method. Cable members are modeled by the elastic catenary cable elements, and towers and main girders are discretized by linear 3-D frame elements. The sensitivities of displacement with respect to the unstrained lengths of selected cables and the pull-up force of the derrick crane are evaluated by the direct differentiation of the equilibrium equation. A Monte-Carlo simulation approach is proposed to estimate expected construction errors for a given confidence level. The proposed method is applied to the second Jindo Grand Bridge to demonstrate its validity and effectiveness.

Covalent Organic Frameworks for Extremely High Reversible $CO_2$ and $H_2$ Uptake Capacity : A Multiscale Simulation Approach (우수한 가역적 이산화탄소 및 수소 저장성능을 가지는 공유결합성 유기적 골격구조체에 관한 다중스케일 접근법을 이용한 연구)

  • Choi, Yoon Jeong;Choi, Jung Hoon;Choi, Kyung Min;Kang, Jeung Ku
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.113.2-113.2
    • /
    • 2010
  • We report that the novel covalent organic frameworks (COFs) are capable of reversibly providing an extremely high uptake capacity of carbon dioxide and hydrogen at room temperature. These COFs are designed based on the multiscale simulations approach via the combination of ab initio calculations and force-field calculations. For this goal, we explore the adsorption sites of carbon dioxide and hydrogen on COFs, their porosity, as well as carbon dioxide adsorption isotherms. We identify the binding sites and energies of $CO_2$ on COFs using ab initio calculations and obtain the carbon dioxide adsorption isotherms using grand canonical ensemble Monte Carlo calculations. Moreover, the calculated adsorption isotherms are compared with the experimental values in order to build the reference model in describing the interactions between the $CO_2/H_2$ and the COFs and in predicting the $CO_2$ and $H_2$ adsorption isotherms of COFs. Finally, we design three new COFs, 2D COF-05, 3D COF-05 (ctn), and 3D COF-05 (bor), for the high capacity $CO_2/H_2$ and $H_2$ storage.

  • PDF