• Title/Summary/Keyword: Monitoring Verification System

Search Result 304, Processing Time 0.033 seconds

Remote-Controlled Experiment with Integrated Verification of Learning Outcome

  • Staudt, Volker;Menzner, Stefan;Baue, Pavol
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.604-610
    • /
    • 2010
  • Experiments in electrical engineering should mirror the key components of successful research and development: Understand the basic theory needed, test the resulting concepts by simulation and verify these, finally, in the experiment. For optimal learning outcome continuous monitoring of the progress of each individual student is necessary, immediately repeating those subjects which have not been learned successfully. Classically, this is the task of the teacher. In case of remote-controlled experiments this monitoring process and the repetition of subjects should be automated for optimal learning outcome. This paper describes a remote-controlled experiment combining theory, simulation and the experiment itself with an automated monitoring process. Only the evaluation of the experimental results and their comparison to the simulation results has to be checked by a teacher. This paper describes the details of the educational structure for a remote-controlled experiment introducing active filtering of harmonics. For better understanding the content of the learning material (theory and simulation) as well as the results of the experiment and the underlying booking system are shortly presented.

Summative Usability Assessment of Software for Ventilator Central Monitoring System (인공호흡기 중앙감시시스템 소프트웨어의 사용적합성 총괄평가)

  • Ji-Yong Chung;You Rim Kim;Wonseuk Jang
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.363-376
    • /
    • 2023
  • According to the COVID-19, development of various medical software based on IoT(Internet of Things) was accelerated. Especially, interest in a central software system that can remotely monitor and control ventilators is increasing to solve problems related to the continuous increase in severe COVID-19 patients. Since medical device software is closely related to human life, this study aims to develop central monitoring system that can remotely monitor and control multiple ventilators in compliance with medical device software development standards and to verify performance of system. In addition, to ensure the safety and reliability of this central monitoring system, this study also specifies risk management requirements that can identify hazardous situations and evaluate potential hazards and confirms the implementation of cybersecurity to protect against potential cyber threats, which can have serious consequences for patient safety. As a result, we obtained medical device software manufacturing certificates from MFDS(Ministry of Food and Drug Safety) through technical documents about performance verification, risk management and cybersecurity application.The purpose of this study is to conduct a usability assessment to ensure that ergonomic design has been applied so that the ventilator central monitoring system can improve user satisfaction, efficiency, and safety. The rapid spread of COVID-19, which began in 2019, caused significant damage global medical system. In this situation, the need for a system to monitor multiple patients with ventilators was highlighted as a solution for various problems. Since medical device software is closely related to human life, ensuring their safety and satisfaction is important before their actual deployment in the field. In this study, a total of 21 participants consisting of respiratory staffs conducted usability test according to the use scenarios in the simulated use environment. Nine use scenarios were conducted to derive an average task success rate and opinions on user interface were collected through five-point Likert scale satisfaction evaluation and questionnaire. Participants conducted a total of nine use scenario tasks with an average success rate of 93% and five-point Likert scale satisfaction survey showed a high satisfaction result of 4.7 points on average. Users evaluated that the device would be useful for effectively managing multiple patients with ventilators. However, improvements are required for interfaces associated with task that do not exceed the threshold for task success rate. In addition, even medical devices with sufficient safety and efficiency cannot guarantee absolute safety, so it is suggested to continuously evaluate user feedback even after introducing them to the actual site.

Short-range Monitoring of Marine AtoN Charge and Discharge Controller (해상용 항로표지 충·방전조절기의 근거리 모니터링)

  • Ye, Seong-Hyeon;Han, Soonhee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.933-939
    • /
    • 2015
  • If the Visual Aids(light wave signs) is not supplied the general power it is using solar power system. These power supply systems, the role of the charge/discharge control is very important. Introduction of IT(AIS etc.) for the effective management of the AtoN(Aids to Navigation) is a Visual Aids has been added to the device using the power to charge/discharge control, the need increases. The current charge/discharge controller is attached to the inside of the AtoN and checks on and verification of the maritime environment, depending on the difficulty. In order to resolve these issues in this paper, the Bluetooth module is mounted on the inside of the charge/discharge controller and proposed a possible system monitoring at close range. Advantage of the system implemented is a simple configuration and low installation cost. In addition, it can be applied to a variety of AtoN. Also, it has been able to check the real-time status information of the charge/discharge controller at a short distance in to reduce inspection costs, and reduce risk factors that might occur during check.

Evaluation of Crack Monitoring Field Application of Self-healing Concrete Water Tank Using Image Processing Techniques (이미지 처리 기법을 이용한 자기치유 콘크리트 수조의 균열 모니터링 현장적용 평가)

  • Sang-Hyuk, Oh;Dae-Joong, Moon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.593-599
    • /
    • 2022
  • In this study, a crack monitoring system capable of detecting cracks based on image processing techniques was developed to effectively check cracks, which are the main damage of concrete structures, and a program capable of imaging and analyzing cracks was developed using machine vision. This system provides objective and quantitative data by replacing the appearance inspection that checks cracks with the naked eye. The verification of the development system was applied to the construction site of a self-healing concrete water tank to monitor the crack and the amount of change in the crack width according to age. In the case of crack width detected by image analysis, the difference from the measured value using a digital microscope was up to 0.036 mm, and the crack healing effect of self-healing concrete could be confirmed through the reduction of crack width.

Design and Implementation of Early Warning Monitoring System for Cross-border Mining in Open-pit Mines (노천광산의 월경 채굴 조기경보 모니터링시스템의 설계 및 구현)

  • Li Ke;Byung-Won Min
    • Journal of Internet of Things and Convergence
    • /
    • v.10 no.2
    • /
    • pp.25-41
    • /
    • 2024
  • For the scenario of open pit mining, at present, manual periodic verification is mainly carried out in China with the help of video surveillance, which requires continuous investment in labor cost and has poor timeliness. In order to solve this difficult problem of early warning and monitoring, this paper researches a spatialized algorithmic model and designs an early warning system for open-pit mine transboundary mining, which is realized by calculating the coordinate information of the mining and extracting equipments and comparing it with the layer coordinates of the approval range of the mines in real time, so as to realize the determination of the transboundary mining behavior of the mines. By taking the Pingxiang area of Jiangxi Province as the research object, after the field experiment, it shows that the system runs stably and reliably, and verifies that the target tracking accuracy of the system is high, which can effectively improve the early warning capability of the open-pit mines' overstepping the boundary, improve the timeliness and accuracy of mine supervision, and reduce the supervision cost.

Guideline for the Diagnose of Geotechnical Structure (Underground Oil Storage Cavern) using a Microseismic Monitoring System (음향미소진동기반 모니터링 시스템을 이용한 지반구조물(유류 지하저장시설) 진단평가 가이드라인)

  • Cheon, Dae-Sung;Jung, Yong-Bok
    • Tunnel and Underground Space
    • /
    • v.28 no.4
    • /
    • pp.293-303
    • /
    • 2018
  • Monitoring is the act of collecting and analyzing accurate engineering information using various methods and instruments. The purposes of the monitoring are design verification, construction management, quality control, safety management, and diagnose of structure etc.. The diagnose evaluation of the geotechnical structures corresponds to the confirmation of the structural performance. It is aimed to judge the soundness of geotechnical structures considering the degree of damage due to the environmental change and elapsed time. Recently, microseismicity, which is widely known in Korea, can be used for safety management and diagnoses of structure as it detects the micro-damage without disturbance of the structure. This report provides guideline on the procedure for assessing an underground oil storage cavern using microseismic monitoring techniques. Guidelines cover the selection of monitoring systems, sensor array, sensor installation and operation of systems, and interpretation.

A Study on the Design of Control Logic for Wind Turbine Simulator having Similarity with 3MW Class Wind Turbine (3MW급 풍력터빈을 모사한 풍력터빈 시뮬레이터 제어로직 설계에 관한 연구)

  • Oh, Ki-Yong;Lee, Jae-Kyung;Park, Joon-Young;Lee, Jun-Shin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.810-816
    • /
    • 2012
  • As wind power has increased steadily, the importance of a condition monitoring system is being emphasized to maximize the availability and reliability of a wind turbine. To develop the advanced algorithms for fault detection and lifespan estimation, a wind turbine simulator is essential for verification of the proposed algorithms before applying them to a condition diagnosis & integrity prognosis system. The developed new-type simulator in this paper includes blades and various sensors as well as a motor, a gearbox and a generator of which the existing simulators generally consist. It also has similarity with a 3MW class wind turbine and can be used to acquire operational data from various operation conditions. This paper presents a design method of control logic for the wind turbine simulator, which gives a wind generation method and similar dynamic characteristics with the 3MW wind turbine. Finally, the proposed control logic is verified through experiments.

A Study on the Establishments of Aircraft Noise Abatement Procedures in Gimpo International Airport (김포공항 항공기 저소음 운항절차 수립을 위한 연구)

  • Kim, Yeon-Myung;Park, Jin-Woo;Kim, Young-Il;Son, Jung-Gon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.725-738
    • /
    • 2006
  • The final purpose of this study is to develop noise abatement procedures for minimizing damages caused by aircraft noise, to establish appropriate noise limits and to suggest a plan for imposing surcharges and penalties on aircraft infringing the noise limits. This study establishes noise abatement procedures and suggests a plan to complement and improve upon NMS in Gimpo International Airport by reviewing the NMS structure. In addition, this study establishes a noise limit at each noise monitoring system and a verification system to discriminate infringing aircraft. Finally, this study suggests a control plan for aircraft infringing the noise limit.

  • PDF

A Study on the Establishments of Aircraft Noise Abatement Procedures in Gimpo International Airport (김포공항 항공기 저소음 운항절차 수립을 위한 연구)

  • Kim, Yeon-Myung;Park, Jin-Woo;Kim, Young-Il;Son, Jung-Gon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.5 s.122
    • /
    • pp.379-390
    • /
    • 2007
  • The final purpose of this study is to develop noise abatement procedures for minimizing damages caused by aircraft noise, to establish appropriate noise limits and to suggest a plan for imposing surcharges and penalties on aircraft infringing the noise limits. This study establishes noise abatement procedures and suggests a plan to complement and improve upon NMS in Gimpo International Airport by reviewing the NMS structure. In addition, this study establishes a noise limit at each noise monitoring system and a verification system to discriminate infringing aircraft. Finally, this study suggests a control plan for aircraft Infringing the noise limit.

HACCP Systems of Contract Foodservice Establishments Appointed by Korea Food and Drug Administration (식품의약품안전청 지정 HACCP 적용 위탁급식소의 HACCP system 조사)

  • 문혜경
    • Korean journal of food and cookery science
    • /
    • v.19 no.1
    • /
    • pp.24-33
    • /
    • 2003
  • The purpose of the study was to investigate the HACCP systems of contract foodservice establishments by surveying HACCP plans and prerequisite programs from the twelve HACCP-implemented contract foodservice establishments appointed by KFDA. All the subjects (100%) appeared to develop HACCP plans with their own hazard analysis. Except the two giving no response, it turned out that two establishments had 2 CCPs (20%), four had 4∼5 CCPs (40%) and another four had 9 CCPs (40%). Especially, 'cleaning and sanitizing of raw vegetables and fruits (90%)' and 'cooking (temperature) (100%)' were monitored as CCPs by all the subjects. Only one subject (8.3%) answered that continuous monitoring was not conducted. But the verification, record keeping and internal audits were maintained by all the subjects (100%). Most of the surveyed foodservice establishments maintained various prerequisite programs enough to back up HACCP system.