• Title/Summary/Keyword: Molecular pump

Search Result 108, Processing Time 0.032 seconds

Effects of Paroxetine on a Human Ether-a-go-go-related Gene (hERG) K+ Channel Expressed in Xenopus Oocytes and on Cardiac Action Potential

  • Hong, Hee-Kyung;Hwang, Soobeen;Jo, Su-Hyun
    • International Journal of Oral Biology
    • /
    • v.43 no.1
    • /
    • pp.43-51
    • /
    • 2018
  • $K^+$ channels are key components of the primary and secondary basolateral $Cl^-$ pump systems, which are important for secretion from the salivary glands. Paroxetine is a selective serotonin reuptake inhibitor (SSRI) for psychiatric disorders that can induce QT prolongation, which may lead to torsades de pointes. We studied the effects of paroxetine on a human $K^+$ channel, human ether-a-go-go-related gene (hERG), expressed in Xenopus oocytes and on action potential in guinea pig ventricular myocytes. The hERG encodes the pore-forming subunits of the rapidly-activating delayed rectifier $K^+$ channel ($I_{Kr}$) in the heart. Mutations in hERG reduce $I_{Kr}$ and cause type 2 long QT syndrome (LQT2), a disorder that predisposes individuals to life-threatening arrhythmias. Paroxetine induced concentration-dependent decreases in the current amplitude at the end of the voltage steps and hERG tail currents. The inhibition was concentration-dependent and time-dependent, but voltage-independent during each voltage pulse. In guinea pig ventricular myocytes held at $36^{\circ}C$, treatment with $0.4{\mu}M$ paroxetine for 5 min decreased the action potential duration at 90% of repolarization ($APD_{90}$) by 4.3%. Our results suggest that paroxetine is a blocker of the hERG channels, providing a molecular mechanism for the arrhythmogenic side effects of clinical administration of paroxetine.

Ion Plating에 의한 알루미늄 산화막 형성

  • 김종민;권봉준;황도진;김명원
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.154-154
    • /
    • 1999
  • 금속산화막은 전자부품 및 광학적 응용에 널리 사용되고 있다. 특히 알루미늄의 산화막은 유전체의 재료로 커패시터에 많이 사용되고 있다. 이러한 알루미늄 산화막을 plasma를 이용한 ion plating에 의해 형성하였다.Activated Reactive Evaporation은 화합물의 증착율을 높이는데 좋은 증착법이다. 이러한 증착법에는 reactive ion plating와 ion-assisted deposition 그리고 ion beam sputtering 등이 있다. 본 연구에서는 알루미늄 산화막을 증착시키기 위해 plasma를 이용한 electron-beam법을 사용하였다. Turbo molecular pump로 챔버 내의 진공을 약 10-7torr까지 낸린 후 5$\times$10-5torr까지 O2와 Ar을 주입시켰다. 각 기체의 분압은 RGA(residual gas analyzer)로 조사하여 일정하게 유지시켰다. plasma를 발생시키기 위해 filament에서 열전자를 방출시키고 1kV 정도의 electrode에 의해 가속시켜 이들 기체들과 반응시켜 plasma를 발생시켰다. 금속 알루미늄을 5kV정도의 고전압과 90mA의 전류로 electron beam에 의해 증발시켰다. 기판의 흡착율을 높ㅇ기 위해 기판에 500V로 bias 전압을 걸어 주었다. 증발된 금속 알루미늄 증기들이 plasmaso의 산소 이온들과 활성 반응을 이루어 알루미늄 기판 위에 Al2O3막을 형성하였다. 알루미늄 산화막을 분석하기 위해 XPS(X-ray Photoelectron Spectroscopy)로 화학적 조성을 조사하였는데, 알루미늄의 2p전자의 binding energy가 76.5eV로 측정되었다. 이는 대부분 증착된 알루미늄이 산소 이온과 반응하여 Al2O3로 형성된 것이다. SEM(Scanning electron Microscopy)과 AFM(Atomim Force microscopy)으로 증착박 표면의 topology와 roughness를 관찰하였다. grain의 크기는 10nm에서 150nm이었고 증착막의 roughness는 4.2nm이었다. 그리고 이 산화막에 전극을 형성하여 유전 상수와 손실률 등을 측정하였다. 이와 같이 plasma를 이용한 3-beam에 의한 증착은 금속의 산화막을 얻는데 유용한 기술로 광학 재료 및 유전 재료의 개발 및 연구에 많이 사용될 것으로 기대된다.

  • PDF

Genomic Analysis of the Extremely Halophilic Archaeon Halobacterium noricense CBA1132 Isolated from Solar Salt That Is an Essential Material for Fermented Foods

  • Lim, Seul Ki;Kim, Joon Yong;Song, Hye Seon;Kwon, Min-Sung;Lee, Jieun;Oh, Young Jun;Nam, Young-Do;Seo, Myung-Ji;Lee, Dong-Gi;Choi, Jong-Soon;Yoon, Changmann;Sohn, Eunju;Rahman, MD. Arif-Ur;Roh, Seong Woon;Choi, Hak-Jong
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.8
    • /
    • pp.1375-1382
    • /
    • 2016
  • The extremely halophilic archaeon Halobacterium noricense is a member of the genus Halobacterium. Strain CBA1132 (= KCCM 43183, JCM 31150) was isolated from solar salt. The genome of strain CBA1132 assembled with 4 contigs, including three rRNA genes, 44 tRNA genes, and 3,208 open reading frames. Strain CBA1132 had nine putative CRISPRs and the genome contained genes encoding metal resistance determinants: copper-translocating P-type ATPase (CtpA), arsenical pump-driving ATPase (ArsA), arsenate reductase (ArsC), and arsenical resistance operon repressor (ArsR). Strain CBA1132 was related to Halobacterium noricense, with 99.2% 16S rRNA gene sequence similarity. Based on the comparative genomic analysis, strain CBA1132 has distinctly evolved; moreover, essential genes related to nitrogen metabolism were only detected in the genome of strain CBA1132 among the reported genomes in the genus Halobacterium. This genome sequence of Halobacterium noricense CBA1132 may be of use in future molecular biological studies.

분자류 영역에 따른 터보분자펌프(TMP) 배기속도 측정에 관한 연구

  • Gang, Sang-Baek;Sin, Jin-Hyeon;Cha, Deok-Jun;Jeong, Wan-Seop;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.46-46
    • /
    • 2010
  • 고진공펌프 중의 하나인 터보분자펌프(turbo-molecular pump: TMP)는 반도체/디스플레이 등 첨단 공정에서 진공 환경을 조성하는 핵심장비로서 현재 한국표준과학연구원 진공기술센터에서 개발 중인 고진공펌프 종합특성평가시스템을 구축 중이며, 1000 L/s 및 2500L/s 배기속도 용량을 가지는 터보분자펌프(TMP)의 database를 구축하고 있다. 이에 터보분자펌프(TMP)의 배기속도 측정 시 사용되는 가스의 분자류 영역에 따른 배기속도의 변화를 연구하고자 한다. 터보분자펌프(TMP)의 배기속도는 분자류 영역에 따라 상이한 배기속도를 가진다. 특히 가벼운 분자들은 터보분자펌프(TMP)로 배기시키기 어려우며, 분자량이 작은 가스들은 분자량이 큰가스 분자들에 비해 압축비(compression ratio)도 작아진다. 압축비가 큰 경우에는 실재 운전조건에 무관하게 배기속도가 최대값을 가지지만, 압축비가 작을 경우에는 운전 시 터보분자펌프(TMP)의 압축비에 따라 배기속도가 달라 질 수 있으며, 압축비는 펌프의 inlet에서의 압력과 exhaust에서의 압력의 비이다. 즉, 가벼운 기체 분자(H2, He 등)들은 무거운 기체 분자(N2, Ar 등)들에 비해 배기속력이 작아진다. 현재 개발 중인 한국표준과학연구원 진공기술센터의 고진공 종합특성평가시스템을 이용하여 분자류 영역에 따른 가벼운 기체 분자와 무거운 기체 분자의 배기속도를 측정하여 분자류 영역에 따라 상이한 배기속도의 변화를 연구하고자 한다. 본 논문에서는 터보분자펌프(TMP)의 분자류 영역에 따른 가벼운 기체 He과 무거운 기체 N2를 사용하여 압축비의 변화와 배기속도 측정에 관해 상관관계를 제시하며, 분자류 영역에 따른 터보분자펌프(TMP)의 배기속도 운전성능을 제시하고자 한다.

  • PDF

Generation of Femtosecond Pulses in a Passively Mode-Locked 100 MHz Cr4+:YAG Laser (수동 모드 잠금된 100 MHz Cr4+:YAG 레이저에서의 펨토초 펄스 발생)

  • Cho, Won-Bae;Rotermund Fabian;Kim, Jong-Doo;Jeon, Min-Yong;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.535-541
    • /
    • 2005
  • We report on the development of a passively mode-locked near-infrared femtosecond laser with Cr:YAG crystal that operates near room temperature. The laser wavelength could easily be tuned by using only the internal prism pair over 110 nm from 1400 nm to 1510 nm in cw and over about 30 nm in mode-locked operation, respectively Maximum cw output powers of 810 mW were obtained with $1.5 \%$ output coupler for absorbed pump powers of 7.6 W. For compensation of the internal group velocity dispersion, an IR graded prism pair was used. The Cr:YAG laser delivered nearly Fourier-transform limited pulses with a pulse duration as short as 64 fs at 100 MHz repetition rate. In the mode-locked regime, the laser was operating at 1510 nm with a spectral bandwidth of 44 nm. In order to avoid unstable mode-locking and power instabilities, self-built tubes were inserted into the beam path in the resonator and purged with N2 gas. Finally, output powers of the Cr:YAG laser were optimized to 250 mW fer long time stable mode-locked operation.

Study on the Measurement of TMP Pumping Speed (터보분자펌프(TMP) 배기속도 측정에 관한 고찰)

  • Kang, S.B.;Shin, J.H.;Cha, D.J.;Koh, D.Y.;Cheung, W.S.;Lim, J.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.4
    • /
    • pp.249-255
    • /
    • 2010
  • Methods of the characteristics evaluation of turbo-molecular pumps (TMP) are well-defined in the international measurement standards such as ISO, PNEUROP, DIN, JIS, and AVS. The Vacuum Center in the Korea Research Institute of Standards and Science (KRISS) has recently designed, constructed, and established the integrated characteristics evaluation system of TMPs based on the international documents by continuously pursuing and acquiring the reliable international credibility through measurement perfection. The measurement of TMP pumping speed is normally performed with the throughput and orifice methods dependent on the mass flow regions. However, in the UHV range of the molecular flow region, the high uncertainties of the gauges, mass flow rates, and conductance are too critical to precisely accumulate reliable data. In order to solve the uncertainty problems of pumping speeds in the UHV range, we introduced a SRG with 1% accuracy and a constant volume flow meter (CVFM) to measure the finite mass flow rates down to $10^{-1}$ Pa-L/s with 3% uncertainty for the throughput method. In this way we have performed the measurement of pumping speed down to $10^{-4}$ Pa with an uncertainty of less than 6% for a 1000 L/s TMP. In this article we suggest that the CVFM has an ability to measure the conductance of the orifice experimentally with flowing the known mass through the orifice chambers, so that we may overcome the discontinuity problem encountering during introducing two measurement methods in one pumping speed evaluation sequence.

Optimal Ratio of Wnt3a Expression in Human Mesenchymal Stem Cells Promotes Axonal Regeneration in Spinal Cord Injured Rat Model

  • Yoon, Hyung Ho;Lee, Hyang Ju;Min, Joongkee;Kim, Jeong Hoon;Park, Jin Hoon;Kim, Ji Hyun;Kim, Seong Who;Lee, Heuiran;Jeon, Sang Ryong
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.705-715
    • /
    • 2021
  • Objective : Through our previous clinical trials, the demonstrated therapeutic effects of MSC in chronic spinal cord injury (SCI) were found to be not sufficient. Therefore, the need to develop stem cell agent with enhanced efficacy is increased. We transplanted enhanced Wnt3-asecreting human mesenchymal stem cells (hMSC) into injured spines at 6 weeks after SCI to improve axonal regeneration in a rat model of chronic SCI. We hypothesized that enhanced Wnt3a protein expression could augment neuro-regeneration after SCI. Methods : Thirty-six Sprague-Dawley rats were injured using an Infinite Horizon (IH) impactor at the T9-10 vertebrae and separated into five groups : 1) phosphate-buffered saline injection (injury only group, n=7); 2) hMSC transplantation (MSC, n=7); 3) hMSC transfected with pLenti vector (without Wnt3a gene) transplantation (pLenti-MSC, n=7); 4) hMSC transfected with Wnt3a gene transplantation (Wnt3a-MSC, n=7); and 5) hMSC transfected with enhanced Wnt3a gene (1.7 fold Wnt3a mRNA expression) transplantation (1.7 Wnt3a-MSC, n=8). Six weeks after SCI, each 5×105 cells/15 µL at 2 points were injected using stereotactic and microsyringe pump. To evaluate functional recovery from SCI, rats underwent Basso-Beattie-Bresnahan (BBB) locomotor test on the first, second, and third days post-injury and then weekly for 14 weeks. Axonal regeneration was assessed using growth-associated protein 43 (GAP43), microtubule-associated protein 2 (MAP2), and neurofilament (NF) immunostaining. Results : Fourteen weeks after injury (8 weeks after transplantation), BBB score of the 1.7 Wnt3a-MSC group (15.0±0.28) was significantly higher than that of the injury only (10.0±0.48), MSC (12.57±0.48), pLenti-MSC (12.42±0.48), and Wnt3a-MSC (13.71±0.61) groups (p<0.05). Immunostaining revealed increased expression of axonal regeneration markers GAP43, MAP2, and NF in the Wnt3a-MSC and 1.7 Wnt3a-MSC groups. Conclusion : Our results showed that enhanced gene expression of Wnt3a in hMSC can potentiate axonal regeneration and improve functional recovery in a rat model of chronic SCI.

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Dry Etching of GaAs and AlGaAs in Diffuion Pump-Based Capacitively Coupled BCl3 Plasmas (확산펌프 기반의 BCl3 축전결합 플라즈마를 이용한 GaAs와 AlGaAs의 건식 식각)

  • Lee, S.H.;Park, J.H.;Noh, H.S.;Choi, K.H.;Song, H.J.;Cho, G.S.;Lee, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.288-295
    • /
    • 2009
  • We report the etch characteristics of GaAs and AlGaAs in the diffusion pump-based capacitively coupled $BCl_3$ plasma. Process variables were chamber pressure ($50{\sim}180$ mTorr), CCP power ($50{\sim}200\;W$) and $BCl_3$ gas flow rate ($2.5{\sim}10$ sccm). Surface profilometry was used for etch rate and surface roughness measurement after etching. Scanning electron microscopy was used to analyze the etched sidewall and surface morphology. Optical emission spectroscopy was used in order to characterize the emission peaks of the $BCl_3$ plasma during etching. We have achieved $0.25{\mu}m$/min of GaAs etch rate with only 5 sccm $BCl_3$ flow rate when the chamber pressure was in the range of 50{\sim}130 mTorr. The etch rates of AlGaAs were a little lower than those of GaAs at the conditions. However, the etch rates of GaAs and AlGaAs decreased significantly when the chamber pressure increased to 180 mTorr. GaAs and AlGaAs were not etched with 50 W CCP power. With $100{\sim}200\;W$ CCP power, etch rates of the materials increased over $0.3{\mu}m$/min. It was found that the etch rates of GaAs and AlGaAs were not always proportional to the increase of CCP power. We also found the interesting result that AlGaAs did not etched at 2.5 sccm $BCl_3$ flow rate at 75 mTorr and 100 W CCP power even though it was etched fast like GaAs with more $BCl_3$ gas flow rates. By contrast, GaAs was etched at ${{\sim}}0.3{\mu}m$/min at the 2.5 sccm $BCl_3$ flow rate condition. A broad molecular peak was noticed in the range of $500{\sim}700\;mm$ wavelength during the $BCl_3$ plasma etching. SEM photos showed that 10 sccm $BCl_3$ plama produced more undercutting on GaAs sidewall than 5 sccm $BCl_3$ plasma.