• Title/Summary/Keyword: Modulation layer

Search Result 230, Processing Time 0.049 seconds

A Study on Data Modeling Techniques for Control Requirements of SPICE Reference Model (SPICE 참조모델 요구사항을 지원하는 데이터 모델링 기법에 관한 연구)

  • Chung Kyu-Jang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.9 no.3
    • /
    • pp.1-6
    • /
    • 2004
  • there needs a new Geographic information system development Technology of the abstraction, encapsulation, modulation and hierarchy using Graphic representation of object modeling Technique. The method is based on composite object of Graphic data with the hierarchy concepts and abstraction of Graphic information in order to improve data abstraction of the graphic data file and described concept of multiple inheritance and classification that supports a wide variety of graphic class such as mesh unit, layer. segment and so on. in simple case of software development using SPICE model and object modeling techniques. this thesis suggested object representation of Graphic data which can reduce software development life cycle and the cost of software maintenance.

  • PDF

A Novel Transflective-type LTPS-LCD with Cap-Divided VA-Mode

  • Kang, Seung-Gon;Kim, Seong-Ho;Song, Seock-Cheon;Park, Won-Sang;Yi, Chung;Kim, Chi-Woo;Chung, Kyu-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.831-833
    • /
    • 2004
  • A novel transflective-type LC mode with good display performance has been developed In order to drive both transmissive and reflective modes simultaneously without any modulation of gamma in a single-gap structure, we have introduced a new design concept in the reflective region, where the capacitance is separated into liquid crystal($C_{LC}$} and organic layer($C_{OL}$), playing a key role as a voltage divider in our cap-divided VA-mode. With this cap-divided method having both merits of simplifying process and good legibility, we have achieved good optical characteristics such as high contrast ratio and wide viewing angle in a single-gap homeotropic panel design.

  • PDF

DSSS-Based Channel Access Technique DS-CDMA for Underwater Acoustic Transmission

  • Lee, Young-Pil;Moon, Yong Seon;Ko, Nak Yong;Choi, Hyun-Taek;Huang, Linyun;Bae, Youngchul
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.1
    • /
    • pp.53-59
    • /
    • 2015
  • This paper proposes a novel method for acoustically and wirelessly transmitting data underwater with a high transmission rate. The method uses the most promising physical layer and multiple access technique (i.e., the code division multiple channel access technique) to divide the channel into subchannels. Data is transmitted through these subchannels. The codes are pseudo-random noise (PN) sequences. In the spread-spectrum technique, a signal such as electrical, electromagnetic, acoustic signal generated in a particular bandwidth is deliberately spread in the frequency domain, which results in a signal with a wider bandwidth. This paper reviews the possibility of application of the direct-sequence code division multiple access (DS-CDMA) technique in an underwater system using MATLAB. As the result of our review, we recognize that the DS-CDMA technique can be applied to underwater environments.

Induction of cytochrome P450 2E1 by 1-bromopropane in male ICR mice (ICR 마우스 수컷에서 1-bromopropane에 의한 cytochrome P450 2E1의 유도)

  • Lee, Sang-Kyu;Jeong, Tae-Cheon
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.3
    • /
    • pp.213-218
    • /
    • 2009
  • 1-bromopropane (1-BP) has been used in numerous purposes such as an intermediate in the synthesis of pharmaceuticals, a solvent for fats, waxes, or resins and a substitute for chlorofluorocarbons that destroy the ozone layer. However, the studies related to the modulation of activities of hepatic cytochrome P450s (CYPs) are not reported yet. This study was the first study to investigate the potential effect for the activities of hepatic CYPs by the treatment of 1-BP in vivo. When 1-BP was treated to male ICR mice by dose-dependently at the dose levels of 200, 500 and 1,000 mg/kg of body weight once, the activity of CYP2E1 was selectively increased for 24 h. The inductive potency for the activity of CYP2E1 by 1-BP was equal to induction by acetone a well-known selective CYP2E1 inducer. The present results indicated that 1-BP would affect the metabolism of 1-BP itself and/or other xenobiotics.

Performance Analysis and MODEM Implementation of the HDR-WPAN System (HDR-WPAN 시스템의 모뎀 구현 및 성능분석)

  • Ju, Won-Ki;Kim, Yoon-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.1
    • /
    • pp.97-103
    • /
    • 2009
  • In this paper, the structure and detailed specifications of the HDR-WPAN physical layer have been analyzed and the block module of transmitter and receiver have been also designed, and analyzed the performance as well. In the process of transmitter design, it concentrated on all possibility of modulation of QPSK, DQPSK and 16/32/64QAM-TCM, which could be available for mode selection due to the transmission rate. In addition to the receiver module, DQPSK and TCM decoding algorithm is mainly concerned. After designing the transceiver MODEM using VHDL, we have programmed on the platform board and verified the functions of the MODEM. Some experimental results showed that it can be considered a possibility of data communication without error over SNR 22dB.

  • PDF

Novel Multiple Access Schemes for IEEE 802.15.4a Low-rate Ultra-wide Band Systems

  • Zhang, Hong;Hui, Bing;Chang, Kyung-Hi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.7A
    • /
    • pp.682-687
    • /
    • 2010
  • The IEEE 802.15.4a specification targets the low-rate (LR) Impulse-radio (IR) ultra-wideband (UWB) system which is now widely applied in the WPANs considering rather short distance communications with low complexity and power consumption. The physical (PHY) layer uses concatenated coding with mixed binary phase-shift keying and binary pulse-position modulation (BPSK-BPPM), and direct sequence spreading with time hopping in order that both coherent and non-coherent receiver architectures are supported. In this paper, the performances of multiple access schemes compliant with IEEE 802.15.4a specification are investigated with energy detection receiver, which allow avoiding the complex channel estimation needed by a coherent receiver. However, the performance of energy detection receiver is severely degraded by multi-user interference (MUI), which largely diminishes one of the most fascinating advantages of UWB, namely robustness to MUI as well as the possibility to allow parallel transmissions. So as to improve the performance of multiple access schemes, we propose to apply the novel TH sequences as well as to increase the number of TH positions. The simulation results show that our novel multiple access schemes significantly improve the performance against MUI.

A Secure MQAM Scheme Based on Signal Constellation Hopping

  • Zhang, Yingxian;Liu, Aijun;Pan, Xiaofei;Ye, Zhan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.7
    • /
    • pp.2246-2260
    • /
    • 2014
  • In this paper, a secure multilevel quadrature amplitude modulation (MQAM) scheme is proposed for the physical layer security (PLS) of the wireless communications. In the proposed scheme, each transmitted symbol's signal constellation (SC) is hopping with the control of two unique factors: amplitude distortion (AD) factor and phase hopping (PH) factor. With unknown the two factors, the eavesdropper cannot extract effective information from the received signal. We first introduce a security metric, referred to as secrecy gain, and drive a lower bound on the gain that the secrecy capacity can be improved. Then, we investigate the relationship among the secrecy gain, the signal to noise power ratios (SNRs) of the main and wiretap channels, and the secrecy capacity. Next, we analyze the security of the proposed scheme, and the results indicate that the secrecy capacity is improved by our scheme. Specifically, a positive secrecy capacity is always obtained, whether the quality of the main channel is better than that of the wiretap channel or not. Finally, the numerical results are provided to prove the analytical work, which further suggests the security of the proposed scheme.

Characterization of YBCO do SQUID fabricated on sapphire substrate for biomagnetic applications (생체자기 응용을 위한 사파이어 기판 위에 제작된 YBCO dc SQUID 의 특성)

  • Lim, Hae-Ryong;Kim, In-Seon;Kim, Dong-Ho;Park, Yong-Ki;Park, Jong-Chul
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.155-159
    • /
    • 2000
  • YBCO step-edge dc SQUID magnetometers on sapphire substrates have been fabricated. CeO2 buffer layer and YBCO films were deposited in situ on the low angle (${\sim}$35$^{\circ}$) steps formed on the sapphire substrates. Typical 5-${\mu}$m-wide junction has R$_n$ of 5 ${\omega}$ and I$_c$ of 50 ${\mu}$A with large I$_c$R$_n$ product of 250 ${\mu}$V at 77K. According to applied bias current, depth of voltage modulation was changed and maximum voltage was measured 16 ${\mu}$V. Field noise of do SQUID was measured 100${\sim}$300 fT/${\surd}^{Hz}$ in the 1 $^{kHz}$, and about 1.5 pT/${\surd}^{Hz}$ in the 1/f region. For ac bias reversal method, field noise was decreased in the 1/f region. The QRS peak of magnetocardiogram was measured 50 pT in the magnetically shielded room.

  • PDF

DC Characteristics of P-Channel Metal-Oxide-Semiconductor Field Effect Transistors with $Si_{0.88}Ge_{0.12}(C)$ Heterostructure Channel

  • Choi, Sang-Sik;Yang, Hyun-Duk;Han, Tae-Hyun;Cho, Deok-Ho;Kim, Jea-Yeon;Shim, Kyu-Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.2
    • /
    • pp.106-113
    • /
    • 2006
  • Electrical properties of $Si_{0.88}Ge_{0.12}(C)$ p-MOSFETs have been exploited in an effort to investigate $Si_{0.88}Ge_{0.12}(C)$ channel structures designed especially to suppress diffusion of dopants during epitaxial growth and subsequent fabrication processes. The incorporation of 0.1 percent of carbon in $Si_{0.88}Ge_{0.12}$ channel layer could accomodate stress due to lattice mismatch and adjust bandgap energy slightly, but resulted in deteriorated current-voltage properties in a broad range of operation conditions with depressed gain, high subthreshold current level and many weak breakdown electric field in gateoxide. $Si_{0.88}Ge_{0.12}(C)$ channel structures with boron delta-doping represented increased conductance and feasible use of modulation doped device of $Si_{0.88}Ge_{0.12}(C)$ heterostructures.

치료중 실시간 모니터링을 위한 투과형 빔측정장치 개발

  • Kim, Jae-Hong;Swanepoel, M.W.;Dekock, E.A.;Park, Yeon-Su;Yang, Tae-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.315-315
    • /
    • 2010
  • 양성자 빔을 이용하여 두경부 암 치료를 South Africa의 iTHEMBA에서 시행하고 있다. 200 MeV의 양성자 빔라인으로부터 진공에서 대기로 인출하여 노즐을 통과하여 종양세포에 조사된다. 치료계획에 적합하게 빔에너지와 모양을 변환하고, 빔을 모니터링하는 기계적 장치들이 노즐에 구성된다. 빔라인에는 이온챔버, Steering Magnet, Multi-wire 이온챔버, Range trimmer plates, lead scattering plate, Double-wedge energy degrader, Multi-layer Faraday cup, Range modulator, Range monitor, occluding ring, Shielding collimators, Quadrant and monitor ionization chamber, Treatment collimator, 그리고 Wellhofer dosimetry tank로 구성되어 있다. 총길이는 6.6m이며 노즐 끝에서 환자의 isocenter 까지는 30cm 정도 아래에 위치한다. 상기의 배치를 갖는 시스템의 양성자 scattering system의 성능을 MCNPX v2.5.0 Monte Carlo simulation을 실시하였다. 또한 정확한 선량을 실시간으로 측정하는 방법인 투과형 검출기를 개발하여 치료와 빔 특성을 동시에 수행하는 기술개발연구가 보고되고 있다. 본 연구에서는 Multileaf Faraday Cup (MLPC) 검출기 설계구조와 데이터 측정방법에 관한 연구를 수행하고자 한다. 빔의 전송 방향으로 3개층의 $4{\times}4$ 배열의 구조로 48 channel의 전류값을 측정하여 입자빔의 분포를 실시간으로 관측하고, 측정된 전류는 ADC를 거쳐 치료계획에 의해 선택된 영역의 SOBP를 유지하도록 range modulation propeller를 조절하는 feed-back system을 갖춘 방사선치료빔 실시간 측정장치 개발에 관한 결과를 보고하고자 한다.

  • PDF