• Title/Summary/Keyword: Model pump

Search Result 934, Processing Time 0.031 seconds

Optimization of Vane Diffuser in a Mixed-Flow Pump for High Efficiency Design

  • Kim, Jin-Hyuk;Kim, Kwang-Yong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.172-178
    • /
    • 2011
  • This paper presents an optimization procedure for high-efficiency design of a mixed-flow pump. Optimization techniques based on a weighted-average surrogate model are used to optimize a vane diffuser of a mixed-flow pump. Validation of the numerical results is performed through experimental data for head, power and efficiency. Three-level full factorial design is used to generate nine design points within the design space. Three-dimensional Reynoldsaveraged Navier-Stokes equations with the shear stress transport turbulence model are discretized by using finite volume approximation and solved on hexahedral grids to evaluate the efficiency as the objective function. In order to reduce pressure loss in the vane diffuser, two variables defining the straight vane length ratio and the diffusion area ratio are selected as design variables in the present optimization. As the results of the design optimization, the efficiency at the design flow coefficient is improved by 7.05% and the off-design efficiencies are also improved in comparison with the reference design.

Numerical Simulations of Cavitation Flow in Volumetric Gear Pump (회전 용적형 기어펌프의 캐비테이션 유동 해석)

  • Lee, Jung-Ho;Lee, Sang-Wook
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.4
    • /
    • pp.28-34
    • /
    • 2011
  • A volumetric gear pump is often used in extensive industrial applications to provide both high pressure and sufficiently high flow rate by physical displacement of finite volume of fluid with each revolution. Template mesh function in commercial CFD software, PumpLinx, by which 3-D meshes in the complex region between rotor and housing can be readily generated was employed for 3-D flow simulations. For cavitation analysis full cavitation model was included in 3-D simulations. The results showed high pulsation in pressure and flowrate which is implicated in pump vibration and noise. A model test for cavitation visualization was conducted and the results showed good qualitative agreement with numerical prediction.

Feasibility study of ground source heat pump system according to the local climate condition (지역 기후 특성에 따른 지열시스템의 도입경제성 차이에 관한 연구)

  • Nam, Yujin
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.127-131
    • /
    • 2014
  • The ground source heat pump (GSHP) system is a kind of the temperature differential energy system using relatively stable underground temperature as heat source of space heating and cooling. This system can achieve higher performance of system than it of conventional air source heat pump systems. However, its superiority of the system performance is different according to installation location or local climate, because the system performance depends on the underground condition which is decided by annual average air temperature. In this study, in order to estimate the feasibility of the ground source heat pump system according to the local climate, numerical simulation was conducted using the ground heat transfer model and the surface heat balance model. The case study was conducted in the condition of Seoul, Daejeon, and Busan, In the result, the heat exchange rate of Busan was 34.33 W/m as the largest in heating season and it of Seoul was 40.61 W/m as the largest in cooling.

Optimization and dynamic characteristics of the hybrid type vacuum pump (하이브리드 타입 진공펌프의 동특성 및 최적화)

  • Kim, Yong-Hwi;Lee, Jong-Myeong;Ahn, Byeong-Hyun;Ha, Jeong-Min;Choi, Byeong-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.306-310
    • /
    • 2014
  • The purpose of this study is the stability evaluation of a vacuum pump through modal test and rotor dynamics. Eigenvalue was solved by the finite-element method(FEM) using 2D and 3D models, then the modal test result was compared with the FEM result. According to the comparison, the analysis result using the 2D was more accurate than the 3D model. Therefore, rotor dynamics was performed by the 2D model. Campbell diagram and root-locus maps, which were calculated by complex-eigenvalue analysis, were used to evaluate the stability of the rotors of the vacuum pump. And displacement solved by unbalance response analysis was compared with the minimum clearance between two rotors of the vacuum pump. Thus, the vacuum pump is assumed operated under steady state through the evaluation of the rotor dynamics.

  • PDF

A Study for the Performance Improvement of the Main Lubrication Oil Pump (선박용 주 윤활유 펌프의 성능 개선에 대한 연구)

  • Kim, Jin-Young;Chung, Kyung-Nam;Kim, Ju-Baek;Yang, Han-Jo;Lim, Shin-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.660-664
    • /
    • 2004
  • The flow fields of a lubrication oil pump has been simulated by using CFD in order to improve performance of the pump. The grid for the one flow passage is applied for estimating pump performance. The calculation result shows that there are unfavorable flow characteristics of flow recirculation in the casing part by the guide vane. Thus, the guide vane is modified to reduce the recirculation region. Performance test shows that the modified model pump efficiency is increased by $6\%$ at the rated point compared to that of the original model.

  • PDF

Simulation on the Heating Performance of a 2-Stage Compression Heat Pump System Using River Water (하천수열원을 이용한 2단압축 열펌프의 난방성능 시뮬레이션)

  • Park Chasik;Kim Bohyun;Kim Yongchan;Lee Young Soo;Bang Ki-young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1005-1013
    • /
    • 2005
  • The use of river water as a heat source of a heat pump has the advantage in the performance compared to the use of atmospheric air because the temperature variation of river water over the year is relatively small. In this study, the performance of the heat pump system using river water as a heat source was numerically investigated. A simulation model for the 2-stage compression heat pump system was developed with each component model composed of compressors, heat exchangers, a flash tank and electronic expansion devices. The peformance of the heat pump system using river water was improved by $50\%$ compared to that using atmospheric air in winter conditions.

Methodology for Simulation of Trochoid Pump (트로코이드 펌프의 시뮬레이션 방법론)

  • Kim, Myung Sik;Chung, Won Jee;Jeong, Seung Won;Jeon, Ju Yeal
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.465-471
    • /
    • 2013
  • Flow rate control is the uppermost concern for a trochoid hydraulic pump. Cavitation within the flow field of the pump has the greatest effect on the flow control during high-speed pump rotation of approximately 3500~4000 RPM. In this paper, based on AMESim$^{(R)}$ and Solid Works$^{(R)}$, we will present a method to simulate cavitation by analyzing the control factors of a trochoid pump, including the hydraulic pressure change at the outlet, flow rate based on the rotation speed of the inner rotor, leakage through the gap between the outer and inner rotors, and discharging angle of the outlet. The proposed methodology of the [cavitation simulation will enable field engineers to more easily design trochoid pumps, and will allow more concrete control over the flow rate of the pump by realizing an analysis model similar to the actual product model.

Evaluation of Rotor Dynamic Characteristic of Roots Type Vacuum Pump (루츠타입 진공펌프의 동특성 평가)

  • Lee, Jong-Myeong;Kim, Yong-Hwi;Ha, Jeong-Min;Gu, Dong-Sik;Hwang, Ho-Jun;Choi, Byeong-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.264-270
    • /
    • 2011
  • The goal of this study is a stability evaluation through eigenvalue and rotor dynamics analysis of the vacuum pump. The vacuum pump used is a roots type pump, one of the dry middle vacuum pumps, is necessary at the procedure to produce semiconductor and display. The eigenvalue evaluation is solved by numerical analysis through using Modal test and 2D 3D models. Both the experiment and the analysis result are similar, the analysis result using 2D is more oculate the 3D model comparing with test result. So rotor dynamic evaluation is performed through using 2D model. Rotor dynamic evaluation used the campbell diagram and root locus map which were acquired by complex eigenvalue analysis. And we checked minimum clearance of vacuum pump composition between two rotors through unbalance response analysis. Thus, vacuum pump, the target object of this study, was evaluated to be operated stably.

  • PDF

Flow Evaluations of Centrifugal Pump Impeller Using Commercial Code (상용코드를 이용한 원심펌프 임펠러 유동평가)

  • Shim, Chang-Yeul;Hong, Soon-Sam;Kang, Shin-Hyoung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.285-292
    • /
    • 2000
  • Numerical calculation is applied to centrifugal pump at design condition by using commercial code STAR-CD and Tascflow, and these results are compared with experimental data at impeller outlet. Numerical analysis is also performed by changing turbulence model and discretization scheme at design condition using Tascflow. Turbulence model and discretization scheme used to Tascflow are k-$\epsilon$, k-$\omega$ turbulence model and upwind, modified linear profile scheme. W;th the same turbulence model and discretization scheme, two results of STAR-CD and Tascflow are very similar. But there is significant difference in numerical results near hub and shroud of impeller with different kinds of turbulent model and discretization scheme at design condition. And with k- $\omega$ turbulence model and modified linear profile scheme, it is showed that numerical results are very similar to experimental results of impeller outlet

  • PDF

A Study on Contamination Sensitivity and Condition Monitoring for a Pump (펌프의 오염 민감도와 성능 감시에 대한 연구)

  • 이재천
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.124-130
    • /
    • 1998
  • A mathematical model describing gear pump flow degradation in the presense of abrasive particles is presented. The model considers the operating parameters as Sommerfeld number, so that contamination sensitivity test results could be conversed to field application to predict contamination service life. A method to estimate the volumetric efficiency and the contamination level of a pump is proposed by measuring the temperature differences in the fluid. Test results show the validity of the theoretical establishments.

  • PDF