Flow Evaluations of Centrifugal Pump Impeller Using Commercial Code

상용코드를 이용한 원심펌프 임펠러 유동평가

  • 심창열 (서울대학교 터보기계연구실) ;
  • 홍순삼 (서울대학교 터보기계연구실) ;
  • 강신형 (서울대학교 기계항공공학부)
  • Published : 2000.12.01

Abstract

Numerical calculation is applied to centrifugal pump at design condition by using commercial code STAR-CD and Tascflow, and these results are compared with experimental data at impeller outlet. Numerical analysis is also performed by changing turbulence model and discretization scheme at design condition using Tascflow. Turbulence model and discretization scheme used to Tascflow are k-$\epsilon$, k-$\omega$ turbulence model and upwind, modified linear profile scheme. W;th the same turbulence model and discretization scheme, two results of STAR-CD and Tascflow are very similar. But there is significant difference in numerical results near hub and shroud of impeller with different kinds of turbulent model and discretization scheme at design condition. And with k- $\omega$ turbulence model and modified linear profile scheme, it is showed that numerical results are very similar to experimental results of impeller outlet

Keywords