송전선로 직접활선공법의 위험요인과 안전대책에 관한 연구 (A Study on the Hazard Factor and Safety Management at Transmission Line During Live Line Works)

  • 최승동;강경식
    • 대한안전경영과학회지
    • /
    • 제8권3호
    • /
    • pp.51-66
    • /
    • 2006
  • This study was attempted to analyze risk factors and suggest accident prevention in live line works for power transmission lines to be developed and applied in Korea. Safety problem cannot but occur at development of live line works and application to the field. With respect to this, problems likely to occur in the field among works adopting methods of works including live line works for power transmission lines were investigated and analyzed through documentary survey and risk assessment method. The results are summarized as follows. A risk assessment method model was suggested. This method enables scientific and systematic development of safety control. That is, the owner may autonomously induce safety control and build risk assessment database by work process to use them as best training data for workers. Also, in the field, it may induce all workers to participate in safety program and secure safety by making workers seek for safety working method under smooth flow from looking at risk factors to accident prevention activities. It is deemed that this humble study will prevent both accident and injury likely to occur in live line works for power transmission lines.

동북아시아 연계계통의 신뢰도평가 (Reliability Evaluation for Interconnecting the Power Systems in North East Asia)

  • 최재석;권중지;트란트룽틴;윤재영;박동욱;문승일;차준민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.17-19
    • /
    • 2005
  • This paper illustrates the case studies of reliability evaluation for interconnecting power systems in the north east Asia by using the tie line constrained equivalent assisting generator model(TEAG), which has been already developed in the second project year. A reliability evaluation program, it is named, NEAREL. based on the TEAS model was made. The reliability evaluation results for the seven interconnection scenarios of the actual power systems of six countries in the north east Asia are introduced and compared. The reasonable capacity of the tie line for three countries interconnection senario is suggested from sensitivity analysis.

  • PDF

혼합배전계통 선로구성요소 변화를 고려한 선로 서지해석 (Surge Analysis Considering Variation of Line Configuration Factor in Combined Distribution Systems with Power Cables)

  • 김병숙;이장근;한병성;이종범
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.472-480
    • /
    • 2007
  • This paper analyzes overvoltage on testing line for various parameter effect examination. Model systems consist of overhead line and underground cable. The model considered actual characteristic data of distribution lines. and will be constructed at testing yard. The simulations were performed under various line configuration such as cable kinds, cable length, lightning wave, lightning wave time, transformer and branch circuits. The simulation models are established by EMTP/ATPDraw and Line Constants are calculated by ATP_LCC. When lightning surge strikes on conductor of overhead line, EMTP/ATPDraw calculates overvoltage in many cases. Simulation results will be compared with real testing results at testing yard. The compared results will be used to establish protection methods in actual underground distribution systems.

STATCON과 송전계통의 동적응동 분석을 위한 EMTP 시뮬레이션 모델 (EMTP SIMULATION MODEL TO ANALYZE DYNAMIC INTERACTION BETWEEN STATCON AND TRANSMISSION SYSTEM)

  • 한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.446-448
    • /
    • 1995
  • This paper dscribes a detail simulation model with EMTP (Electro-Magnetic Transients Program) which is very effective to analyze the interaction between the ac transmission line and STATCON (static condenser). The SATCON was represented by two voltage-source converters connected in parallel and sharing an energy storage dc capacitor bank. The voltage source converters was modeled with ideal gate turn-off switches. The power system was represented by a detail generator model and a distributed tramnsmission line model for detail performance analyses. Analysis results show that the conceived simulation model is very effective to analyze the interaction between the ac transmission line and STATCON, and to evaluate the performance of STATCON.

  • PDF

전력선 통신 시스템의 입력 임피던스 계산 (Input Impedance Calculation of the Power Line Communication System)

  • 천동완;이진택;박영진;김관호;신철재
    • 한국통신학회논문지
    • /
    • 제29권9A호
    • /
    • pp.983-990
    • /
    • 2004
  • 본 논문에서는 중 전압 전력선을 이용한 전력선 통신대 LC) 네트워크의 입력임피던스를 계산하였다. 먼저 전송 선로 모델을 이용하여 전력선 통신 네트워크의 입출력 단 모델을 제시하였으며, 여기에 전력선의 방사성 손실, 도체손실, 유전체 손실 등에 의한 감쇠상수를 적용시켜 임피던스를 계산하였다 계산결과 방사성 손실에 의한 강쇠 가 가장 크게 나타났으며, 전력선의 특정임피던스가 매우커서 입력 단에서의 반사가 심하기 때문에 입력임피던스 가 일정한 주기를 가지는 정재파 형태로 나타남을 알 수 있었다 또한 입력임피던스의 주기는 동축선로의 길이에 주로 의존하고, 크기는 주로 전력선의 특성임피던스 및 손실에 의존하였다 실제 측정결과 계산 치와 측정치가 매 우 유사함을 알 수 있었다.

송전계통의 인버터식 직.병렬 보상기에 관한 기초연구 (Fundamental study on Inverter-type Series and Shunt Compensator for Transmission System)

  • 한병문;한후석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.425-433
    • /
    • 1999
  • This paper describes a simulation model and a scaled hardware model to analyze the dynamic performance of Unified Power Flow Controller, which can flexibly adjust the active and reactive power flow through the ac transmission line. The design of control system was developed using vector control method. The results of simulation and scaled hardware test show that the developed control system works accurately. And both models are very effective to analyze the dynamic performance of the Unified Power Flow Controller.

  • PDF

최적전력조류 해석을 위한 원도우프로그램 팩키지 개발 (Windows Program Package Development for Optimal Pourer Flour Analysis)

  • 김규호;이상봉;이재규;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권12호
    • /
    • pp.584-590
    • /
    • 2001
  • This paper presents a windows program package for solving security constrained OPF in interconnected Power systems, which is based on the combined application of evolutionary programming(EP) and sequential quadratic programming(SQP). The objective functions are the minimization of generation fuel costs and system power losses. The control variables are the active power of the generating units, the voltage magnitude of the generator, transformer tap settings and SYC setting. The state variables are the bus voltage magnitude, the reactive power of the generating unit, line flows and the tie line flow In OPF considering security, the outages are selected by contingency ranking method. The resulting optimal operating point has to be feasible after outages such as any single line outage(respect of voltage magnitude, reactive power generation and power flow limits). The OPF package proposed is applied to IEEE 14 buses and 10 machines 39 buses model system.

  • PDF

Skew를 고려한 유도기동형 영구자석 동기전동기의 특성 해석 (Characteristic Analysis of Line-start Permanent Magnet Synchronous Motor considering Skew Effect)

  • 오영진;이인우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.12-14
    • /
    • 2005
  • This study investigates the characteristic analysis of Line-start Permanent Magnet Synchronous Motor considering skew effect. The effects of the skew on machine characteristic are analyzed by using direct co-simulation of Matlab Simulink and Flux2D. Validity of analysis method is confirmed by the analysis result of Non-skew Model.

  • PDF

검침데이터를 이용한 전력설비 시공간 부하분석모델 (Spatio-temporal Load Analysis Model for Power Facilities using Meter Reading Data)

  • 신진호;김영일;이봉재;양일권;류근호
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1910-1915
    • /
    • 2008
  • The load analysis for the distribution system and facilities has relied on measurement equipment. Moreover, load monitoring incurs huge costs in terms of installation and maintenance. This paper presents a new model to analyze wherein facilities load under a feeder every 15 minutes using meter reading data that can be obtained from a power consumer every 15 minute or a month even without setting up any measuring equipment. After the data warehouse is constructed by interfacing the legacy system required for the load calculation, the relationship between the distribution system and the power consumer is established. Once the load pattern is forecasted by applying clustering and classification algorithm of temporal data mining techniques for the power customer who is not involved in Automatic Meter Reading(AMR), a single-line diagram per feeder is created, and power flow calculation is executed. The calculation result is analyzed using various temporal and spatial analysis methods such as Internet Geographic Information System(GIS), single-line diagram, and Online Analytical Processing (OLAP).

UPFC의 동적 성능해석을 위한 시뮬레이션 모형 (Simulation Model for Dynamic Performance Analysis of UPFC)

  • 한병문;최대길;신익상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.479-481
    • /
    • 1996
  • This paper describes a simulation model to analyze the dynamic performance of Unified Power Flow Controller which ran flexibly adjust the active and reactive power flow through the ac transmission line. An equivalent circuit to analyze the basic principle for the whole system operation was developed and a control system for the Unified Power Flow Controller was derived using vector control method. A computer simulation model with EMTP code was also conceived to evaluate the performance of the Unified power Flow Controller. The simulation results show that Unified Power flow Controller is very effective for controlling the power flow and damping the subsynchronous resonance in the power system.