• Title/Summary/Keyword: Mode Method

Search Result 8,090, Processing Time 0.033 seconds

Significance of Apoptotic Cell Death after $\gamma-Irradiation$ (방사선 조사에 의한 세포사에 있어서 세포고사의 의미)

  • Wu H.G.;Kim I.H.
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.252-258
    • /
    • 2001
  • Purpose : The objectives of this study are to investigate the significance of apoptotic death compared to total cell death after $\gamma-ray$ irradiation in human H&N cancer cell lines and to find out correlation between apoptosis and radiation sensitivity. Materials and method : Head and neck cancer cell lines (PCI-1, PCI-13, and SNU-1066), leukemia cell line (CCRF-CEM), and fibroblast cell line (LM217) as a normal control were used for this study. Cells were irradiated using Cs-137 animal experiment irradiator. Total cell death was measured by clonogenic assay. Annexin-V staining was used to detect the fraction of apoptotic death. Results : Surviving fraction at 2 Gy (SF2) were 0.741, 0.544, 0.313, 0.302, and 0.100 for PCI-1, PCI-13, SNU-1066, CCRF-CEM, and LM217 cell lines, respectively. Apoptosis was detected in all cell lines. Apoptotic index reached peak value at 72 hours after irradiation in head and neck cancer cell lines, and that was at 24 hours in CCRF-CEM and LM217. Total cell death increased exponentially with increasing radiation dose from 0 Gy to 8 Gy, but the change was minimal in apoptotic index. Apoptotic fractions at 2 Gy were $46\%,\;48\%,\;46\%,\;24\%,\;and\;19\%$ and at 6 Gy were $20\%,\;33\%,\;35\%,\;17\%,\;and\;20\%$ for PCI-1, PCI-13, SNU-1066, CCRF-CEM, and LM217, respectively. The radioresistant cell lines showed more higher apoptotic fraction at 2 Gy, but there was not such correlation at 6 Gy. Conclusion : All cell lines used in this study showed apoptosis after irradiation, but time course of apoptosis was different from that of leukemia cell line and normal fibroblast cell line. Reproductive cell death was more important mode of cell death than apoptotic death in all cell lines used in this study. But there was correlation between apoptotic fraction and radiation sensitivity at 2 Gy.

  • PDF

Assessment of Attenuation Correction Techniques with a $^{137}Cs$ Point Source ($^{137}Cs$ 점선원을 이용한 감쇠 보정기법들의 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Son, Hye-Kyoung;Park, Yun-Young;Park, Hae-Joung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.57-68
    • /
    • 2005
  • Purpose: The objective of this study was to assess attenuation correction algorithms with the $^{137}Cs$ point source for the brain positron omission tomography (PET) imaging process. Materials & Methods: Four different types of phantoms were used in this study for testing various types of the attenuation correction techniques. Transmission data of a $^{137}Cs$ point source were acquired after infusing the emission source into phantoms and then the emission data were subsequently acquired in 3D acquisition mode. Scatter corrections were performed with a background tail-fitting algorithm. Emission data were then reconstructed using iterative reconstruction method with a measured (MAC), elliptical (ELAC), segmented (SAC) and remapping (RAC) attenuation correction, respectively. Reconstructed images were then both qualitatively and quantitatively assessed. In addition, reconstructed images of a normal subject were assessed by nuclear medicine physicians. Subtracted images were also compared. Results: ELEC, SAC, and RAC provided a uniform phantom image with less noise for a cylindrical phantom. In contrast, a decrease in intensity at the central portion of the attenuation map was noticed at the result of the MAC. Reconstructed images of Jaszack and Hoffan phantoms presented better quality with RAC and SAC. The attenuation of a skull on images of the normal subject was clearly noticed and the attenuation correction without considering the attenuation of the skull resulted in artificial defects on images of the brain. Conclusion: the complicated and improved attenuation correction methods were needed to obtain the better accuracy of the quantitative brain PET images.

Simultaneous Determination of Aminoglycoside Antibiotics in Meat using Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS를 이용한 육류 중 아미노글리코사이드계 항생제 9종의 동시분석 및 적용성 검증)

  • Cho, Yoon-Jae;Choi, Sun-Ju;Kim, Myeong-Ae;Kim, MeeKyung;Yoon, Su-Jin;Chang, Moon-Ik;Lee, Sang-Mok;Kim, Hee-Jeong;Jeong, Jiyoon;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.123-130
    • /
    • 2014
  • A simultaneous determination was developed for 9 aminoglycoside antibiotics (amikacin, apramycin, dihydrostreptomycin, gentamicin, hygromycin B, kanamycin, neomycin, spectinomycin, and streptomycin) in meat by liquid chromatography tandem mass spectrometry (LC-MS/MS). Each parameter was established by multiple reaction monitoring in positive ion mode. The developed method was validated for specificity, linearity, accuracy, and precision based on CODEX validation guideline. Linearity was over 0.98 with calibration curves of the mixed standards. Recovery of 9 aminoglycosides ranged on 60.5~114% for beef, 60.1~112% for pork and 63.8~131% for chicken. The limit of detection (LOD) and limit of quantification (LOQ) were 0.001~0.009 mg/kg and 0.006~0.03 mg/kg, respectively in livestock products including beef, pork and chicken. This study also performed survey of residual aminoglycoside antibiotics for 193 samples of beef, pork and chicken collected from 9 cities in Korea. Aminoglycosides were not found in any of the samples.

Effect of cavity shape, bond quality and volume on dentin bond strength (와동의 형태, 접착층의 성숙도, 및 와동의 부피가 상아질 접착력에 미치는 영향)

  • Lee, Hyo-Jin;Kim, Jong-Soon;Lee, Shin-Jae;Lim, Bum-Soon;Baek, Seung-Ho;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.450-460
    • /
    • 2005
  • The aim of this study was to evaluate the effect of cavity shape, bond quality of bonding agent and volume of resin composite on shrinkage stress developed at the cavity floor. This was done by measuring the shear bond strength with respect to iris materials (cavity shape , adhesive-coated dentin as a high C-factor and Teflon-coated metal as a low C-factor), bonding agents (bond quality: $Scotchbond^{TM}$ Multi-purpose and Xeno III) and iris hole diameters (volume; 1mm or 3mm in $diameter{\times}1.5mm$ in thickness). Ninety-six molars were randomly divided into 8 groups ($2{\times}2{\times}2$ experimental setup). In order to simulate a Class I cavity, shear bond strength was measured on the flat occlusal dentin surface with irises. The iris hole was filled with Z250 restorative resin composite in a bulk-filling manner. The data was analyzed using three-way ANOVA and the Tukey test. Fracture mode analysis was also done When the cavity had high C-factor, good bond quality and large volume, the bond strength decreased significantly The volume of resin composite restricted within the well-bonded cavity walls is also be suggested to be included in the concept of C-factor, as well as the cavity shape and bond quality. Since the bond quality and volume can exaggerate the effect of cavity shape on the shrinkage stress developed at the resin-dentin bond, resin composites must be filled in a method, which minimizes the volume that can increase the C-factor.

Research on the influence of web celebrity live broadcast on consumer's purchase intention - Adjusting effect of web celebrity live broadcast contextualization

  • Zou, Ji-Kai;Guo, Han-Wen;Liu, Zi-Yang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.239-250
    • /
    • 2020
  • The purpose of this paper is to explore the influence of the "contextualization" effect of web celebrity live broadcast on the e-commerce platform on consumers' perception of product value, risk and purchase intention. Live in this paper, using Taobao shopping consumers as the research object, the survey method, questionnaire survey is adopted, the form through the questionnaire and distributed network, a live in order to further validation of web celebrity effect of contextualized actual influence on consumer purchase intention, questionnaire design the Likert scale, seven and recycling questionnaire analysis using the statistical software SPSS 23.0 and AMOS 22.0 after processing the data. After determining the reliability and validity of the questionnaire, the exploratory factor analysis was used to verify the hypothesis and calculate the actual adjustment degree of the "contextualization" effect of web celebrity live broadcasting on consumers' purchase intention. The research results of this paper are summarized as follows :(1) consumers' perceived value of products can significantly positively affect their purchase intention, while perceived risk has a significantly negative impact on their purchase intention; (2) consumers' trust and purchase intention to products are regulated by the "contextualization" of web celebrity live broadcast. Specifically, for web celebrity live broadcasting with good "contextualization" effect, the perceived value of consumer products has a positive impact on product trust, which is higher than that of web celebrity live broadcasting with poor "contextualization" effect. In terms of resolving consumers' perceived risks to products, web celebrity live broadcast with good "contextualization" effect is also significantly better than web celebrity live broadcast with poor "contextualization" effect. Based on empirical analysis, this paper concludes that web celebrity live broadcasting will become a new breakthrough for the sustainable growth of the e-commerce industry, and puts forward Suggestions on the e-commerce marketing mode and the transformation of web celebrity live broadcasting industry.

A Study on the Transmission of 'Soeburi-Song' in Ulsan (울산쇠부리소리의 전승 양상)

  • Yang, Young-Jin
    • (The) Research of the performance art and culture
    • /
    • no.37
    • /
    • pp.157-186
    • /
    • 2018
  • Ulsan Soeburi song was reenacted in the 1980s based on the testimony and songs of late Choi Jae man (1987 death), the last blacksmith of the iron production plant at Dalcheon dong, Ulsan in August 1981. The purpose of this study is to analyze Soeburi song from the musical perspective based on 13 kinds of data including video in 1981, and confirm the changing patterns in the tradition process. The derived results are summarized as follows. In the results of examining Soeburi Song data in 2017, the percussion instruments consist of kkwaenggwari 2 (leading small gong 1, follow small gong 1), jing 2 (large gong 2), buk 4 (drum 4), janggu 4 (double headed drum 4), taepyongso 1 (Korean shawm 1), and Jangdan (rhythm) consists of five such as Jilgut, Jajinmori, Dadeuraegi, Deotbaegi, Jajin Deotbaegi. The vocal songs are sung accompanied by the Deotbaegi Jajin Deotbaegi (beat) of quarter small triplet time, or without accompaniment. The scale is mostly Mi La do's third note or Mi La do re's fourth note, and the range does not exceed one octave. All the cadence tones are the same as La. From the results of observing Soeburi song performance until today after the excavation in 1981, it is found that there are four major changes. First, the composition of the music is differentiated into 'long Jajin (slow fast)', and , , and are added. Second, the singing method is based on 'single cantor + multi post singers' since 1980's reenactment, and a single post singer was also specified from time to time. In addition, , which was performed in 2013, became the foundation of . Third, a melodic change of was observed. All beat structures are quarter small triplet time, but the speed gets slow, Mi La do's three notes are skeletonized to be corrected with high re and low sol, and then the characteristics of Menari tori (the mode appeared in the eastern province of the Korean peninsula) are to be clear. Lastly, the four percussion instruments such as kkwaenggwari, jing, janggu, and buk are frequently used, and depending on the performance, sogo (hand drum), taepyongso, yoryeong (bell) are also added. Jangdan played Jajinmori, Dadeuraegi, Deotbaegi and Jajin Deotbaegi from the beginning, and thereafter, the Jilgut Jangdan was added. Through these results as above, it is confirmed that at the time of the first excavation, a simple form of such as has been changed into a male labor song, the purpose of which has changed, and that the playability has become stronger and changed into a performing arts.

Effect of Ta/Cu Film Stack Structures on the Interfacial Adhesion Energy for Advanced Interconnects (미세 배선 적용을 위한 Ta/Cu 적층 구조에 따른 계면접착에너지 평가 및 분석)

  • Son, Kirak;Kim, Sungtae;Kim, Cheol;Kim, Gahui;Joo, Young-Chang;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • The quantitative measurement of interfacial adhesion energy (Gc) of multilayer thin films for Cu interconnects was investigated using a double cantilever beam (DCB) and 4-point bending (4-PB) test. In the case of a sample with Ta diffusion barrier applied, all Gc values measured by the DCB and 4-PB tests were higher than 5 J/㎡, which is the minimum criterion for Cu/low-k integration without delamination. However, in the case of the Ta/Cu sample, measured Gc value of the DCB test was lower than 5 J/㎡. All Gc values measured by the 4-PB test were higher than those of the DCB test. Measured Gc values increase with increasing phase angle, that is, 4-PB test higher than DCB test due to increasing plastic energy dissipation and roughness-related shielding effects, which matches well interfacial fracture mechanics theory. As a result of the 4-PB test, Ta/Cu and Cu/Ta interfaces measured Gc values were higher than 5 J/㎡, suggesting that Ta is considered to be applicable as a diffusion barrier and a capping layer for Cu interconnects. The 4-PB test method is recommended for quantitative adhesion energy measurement of the Cu interconnect interface because the thermal stress due to the difference in coefficient of thermal expansion and the delamination due to chemical mechanical polishing have a large effect of the mixing mode including shear stress.

Development of Electret to Improve Output and Stability of Triboelectric Nanogenerator (마찰대전 나노발전기의 출력 및 안정성 향상을 위한 일렉트렛 개발)

  • Kam, Dongik;Jang, Sunmin;Yun, Yeongcheol;Bae, Hongeun;Lee, Youngjin;Ra, Yoonsang;Cho, Sumin;Seo, Kyoung Duck;Cha, Kyoung Je;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.93-99
    • /
    • 2022
  • With the rapid development of ultra-small and wearable device technology, continuous electricity supply without spatiotemporal limitations for driving electronic devices is required. Accordingly, Triboelectric nanogenerator (TENG), which utilizes static electricity generated by the contact and separation of two different materials, is being used as a means of effectively harvesting various types of energy dispersed without complex processes and designs due to its simple principle. However, to apply the TENG to real life, it is necessary to increase the electrical output. In addition, stable generation of electrical output, as well as increase in electrical output, is a task to be solved for the commercialization of TENG. In this study, we proposed a method to not only improve the output of TENG but also to stably represent the improved output. This was solved by using the contact layer, which is one of the components of TENG, as an electret for improved output and stability. The utilized electret was manufactured by sequentially performing corona charging-thermal annealing-corona charging on the Fluorinated ethylene propylene (FEP) film. Electric charges artificially injected due to corona charging enter a deep trap through the thermal annealing, so an electret that minimizes charge escape was fabricated and used in TENG. The output performance of the manufactured electret was verified by measuring the voltage output of the TENG in vertical contact separation mode, and the electret treated to the corona charging showed an output voltage 12 times higher than that of the pristine FEP film. The time and humidity stability of the electret was confirmed by measuring the output voltage of the TENG after exposing the electret to a general external environment and extreme humidity environment. In addition, it was shown that it can be applied to real-life by operating the LED by applying an electret to the clap-TENG with the motif of clap.

Structural Behavior Evaluation of NRC Beam-Column Connections (NRC 보-기둥 접합부의 구조적 거동 평가)

  • Jeon, Ji-Hwan;Lee, Sang-Yun;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.73-80
    • /
    • 2022
  • In this study, details of NRC beam-column connections were developed in which beam and columns pre-assembled in factories using steel angles were bolted on site. The developed joint details are NRC-J type and NRC-JD type. NRC-J type is a method of tensile joining with TS bolts to the side and lower surfaces of the side plate of the NRC column and the end plate of the NRC beam. NRC-JD type has a rigid joint with high-strength bolts between the NRC beam and the side of the NRC column for shear, and with lap splices of reinforcing bar penetrating the joint and the beam main reinforcement for bending. For the seismic performance evaluation of the joint, three specimens were tested: an NRC-J specimen and NRC-JD specimen with NRC beam-column joint details, and an RC-J specimen with RC beam-column joint detail. As a result of the repeated lateral load test, the final failure mode of all specimens was the bending fracture of the beam at the beam-column interface. Compared to the RC-J specimen, the maximum strength of the specimen by the positive force was 10.1% and 29.6% higher in the NRC-J specimen and the NRC-JD specimen, respectively. Both NRC joint details were evaluated to secure ductility of 0.03 rad or more, the minimum total inter-story displacement angle required for the composite intermediate moment frame according to the KDS standard (KDS 41 31 00). At the slope by relative storey displacemet of 5.7%, the NRC-J specimen and the NRC-JD specimen had about 34.8% and 61.1% greater cumulative energy dissipation capacity than the RC specimen. The experimental strength of the NRC beam-column connection was evaluated to be 30% to 53% greater than the theoretical strength according to the KDS standard formula, and the standard formula evaluated the joint performance as a safety side.

Periprosthetic Fracture around Tumor Prosthesis, Comparison of Results with or without Cortical Strut Onlay Allograft (종양인공관절 주위 골절의 피질골 지주 중첩 동종골 이식술 유무에 따른 결과 비교)

  • Kim, Yongsung;Cho, Wan Hyeong;Song, Won Seok;Lee, Kyupyung;Jeon, Dae-Geun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.42-50
    • /
    • 2021
  • Purpose: Periprosthetic fractures of a tumor prosthesis are rare but have difficulties in achieving sound fixation because of the poor bone quality, which increases the risk of loosening or re-fracture, even after bone union. A cortical strut onlay allograft was adopted for peri-prosthetic fractures after hip arthroplasty into the periprosthetic fracture of a tumor prosthesis, assuming that it would assist in firm fixation, shorten the time to union, and increase the bone stock, thereby, lower the chance of loosening and re-fracture. Materials and Methods: This study reviewed 27 patients (30 cases) of periprosthetic fracture of tumor prosthesis. Sixteen cases (allograft group) had augmentation with an onlay allograft, while 14 cases (conventional group) had internal fixation or conservative treatment. The following were assessed; mode of periprosthetic fracture, difference in the time to union between a strut cortical onlay allograft and without it, and survival of prosthesis, complication, and functional outcome between the two groups. Results: According to the unified classification system (UCS), 21 cases were type B (70.0%; B1, 14; B2, 1; B3, 6) and 9 cases were type C. The five-, 10-year survival of the 30 reconstructions by Kaplan-Meier plot was 84.5%±4.18% and 42.2%±7.83%, respectively. The average time to bone union of the entire cohort was 5.1 months (range, 2.0-11.2 months). The allograft group (3.5 months) showed a shorter period for union than the conventional group (7.2 months) (p<0.0001). All four cases of major complications occurred in the conventional group. Two cases with loosening and anterior angulation were treated with a change of prosthesis, and another with infection underwent amputation. The remaining case with loosening had conservative management. At the final follow-up, the average Musculosketal Tumor Society score of the allograft group (26.1) was better than that of the conventional group (20.9). Conclusion: Bone union in periprosthetic fractures of a tumor prosthesis can be achieved, but the minimization of complications is important. An onlay allograft facilitates firm fixation and increases the bone stock with a shortened time to union. This simple method can minimize the risk of loosening, joint contracture, and re-fracture.