• 제목/요약/키워드: Mock-up specimens

검색결과 50건 처리시간 0.021초

유화처리 정제식용유(ERCO) 사용에 따른 고성능 콘크리트의 Mock-up 및 강도특성 (Strength Property and Mock-up Test of the High Performance Concrete with Emulsified Refined Cooking Oil)

  • 조만기;강병회;이동규;박규연;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.136-137
    • /
    • 2014
  • In this study, fundamental performances of high strength concrete with ERCO has been analysed according to mock-up test. The following results could be made as the conclusion. For the fresh concrete, flowability and air content decreased with the addition of ERCO, and all the specimens satisfied the target range. For the strength properties, all the specimens with different nominal strength showed higher compressive srength than Plain which with 0% dosage of ERCO.

  • PDF

설계강도 150 MPa 초고강도 콘크리트 개발 (Development of 150 MPa Ultra High Strength Concrete)

  • 손유신;김한준;김규동;이승훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.29-32
    • /
    • 2006
  • The techniques related to ultra-high strength concrete(UHSC) became the key issue in recent days since requirements of the high-rise building which story is over than 100 gradually increases. Therefore, for the development of 150MPa UHSC this research is generally categorized by 4 parts: development of pre-mixed binders, evaluation for the fire performance of coarse aggregate, optimization of the mixture proportion, and mock-up test. Finally, based on the optimized mixture and its laboratory tests, mock-up test for wall and column specimens were carried out to simulate and evaluate the UHSC in real situation. The mechanical properties of core specimens were compared with the cylinder specimens made in laboratory. For instance, it showed the reasonable the results that the strength at the age of 91 days is 183MPa.

  • PDF

폴리비닐아세테이트(PVAc)를 이용한 복합공법의 수밀성능 향상에 관한 연구 (A Study on Watertightness Improvement of Hybrid Method Using Polyvinyl Acetate(PVAc))

  • 류재석;송일현;이용수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권4호
    • /
    • pp.18-24
    • /
    • 2012
  • 본 연구에서는 시멘트에 작용하는 아크릴 코폴리머의 화학반응을 통해 강한 점착성과 유연성을 가지는 친환경적인 폴리비닐아세테이트(PVAc)를 이용하여 수밀성을 향상시키는 복합공법의 가능성을 알아보고자 하였으며, 이를 위한 실험 방법으로 1차로 실리케아트계 침투성 방수제를 도포 한 후, 2차로 PVAc를 혼입한 모르타를 도포한 후에 부착강도 및 흡수량에 대한 특성을 검토하였다. 이 실험 결과를 토대로 하여 현장 적용을 위한 Mock-up 부재를 제작하였고, 이 시험 부재에 대하여 복합공법을 적용한 후 실내 시험과 동일한 성능을 검토하였다. 또한, 탄산화 및 염소 이온 침투저항성 평가를 실시하여 내구성이 취약한 환경에 적합한지 여부를 검토 하였다. 그 결과 PVAc를 이용한 복합공밥을 적용한 시험체가 수밀성능이 가장 우수하였으며, 부착강도 또한 우수한 성능을 나타내었다. 또한, 간이 Mock-up 부재에 대한 성능평가에서 실내 시험과 동일한 경향을 보였으며, 압축강도 시험결과 보강 효과를 발휘함을 알 수 있었다. 탄산화 및 염소 이온 침투저항성 내구 성능 평가에서 가장 우수한 결과를 나타내어 지하구조물 및 해양구조물 등과 같은 취약한 지역에 적용이 가능함을 확인 할 수 있었다.

실물대시험에서의 양생방법 차이에 따른 한중콘크리트의 온도이력 및 강도특성에 관한 연구 (A Study on the Strength Properties and the Temperature Hysteresis of Winter Concrete according to the difference of Curing Method in Mock-up Test)

  • 원철;한천구
    • 한국건축시공학회지
    • /
    • 제3권4호
    • /
    • pp.87-94
    • /
    • 2003
  • This study is to investigate the temperature hysteresis and development of compressive strength due to the curing conditions and to evaluate the optimum curing condition of test specimens showing the same development of strength to that of real structures in cold weather. The results of temperature curve with curing conditions in mock-up tests showed the trend of decrease plain concrete with insulation form, plain concrete with heating, concrete with accelerator for freeze protection, and control concrete in turn. The strength development of plain concrete of inside and outside of shelter showed the very slow strength gains due to early freezing, but that of concrete with accelerator for freeze protection showed the gradual increase of strength with time. From this, it is clear that accelerator for freeze protection has the effects of refusing the freezing temperature and accelerating the hardening under low temperature. Strength test results of small specimens embedded in members and located in insulation boxes at the site are similar to that of cores drilled from the members at the same ages, thus it is clear that these curing methods are effective for evaluating in-place concrete strength

유동화 공법을 적용한 노출 콘크리트 배합의 현장적용성에 관한 Mock-up Test (The Mock-up Test of the Exposed Concrete by Applying the Flowing Concrete Method)

  • 손호정;박경택;홍석민;오치현;한천구;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.165-167
    • /
    • 2011
  • This study is to evaluate the feasibility of the mix design for exposed concrete. Mock-up sized specimens were prepared, and a flowing concrete method was selected for placement. Results showed that the fluidity and air content of fresh concrete achieved target values, the compressive strength at 7 days was 27 MPa, and surface roughness was in the range of between around 1.53 and 1.68 ㎛, which was in the quality level. Therefore it is concluded that the proposed mix design for exposed concrete can be applied in practice.

  • PDF

환원슬래그를 이용하여 개발된 자기발열 시멘트의 해외 Mock-up Test 관한 연구 (International Test Mock-up of the Self-Heating of Cement Developed using a Reducing Slag)

  • 민태범;최현국;김형철;김재영;안동희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.228-229
    • /
    • 2017
  • MOCK-UP TEST was conducted in the extreme region of the cement which was researched and developed by using the reducing slag Experimental results show that the basic properties (air volume, slump) are improved compared with the specimens using Mongolian cement. The compressive strength achieved the target strength (target strength: age 3day: 7MPa, age 7day 14MPa) and the hydration heat was about 8 ℃ higher than that of Mongolian cement products. Therefore, it is considered that the cement powders developed by our company showed the strength of concrete due to high hydration heat even at extreme temperatures.

  • PDF

굵은 입자 시멘트 및 플라이애시를 복합 사용한 콘크리트의 Mock-up Test (Mock-up Test of Concrete using Combined Coarse particle Cement and Fly-Ash)

  • 이충섭;이재윤;장덕배;김영필;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.87-91
    • /
    • 2009
  • This study investigates possibility for practical use through small sized test with OPC and substituted fly ash 10% and return coarse cement (RCC), classed 1100${\sim}$1200 cm2/g, which is made by Cyclone Separator at cement producing process 20% (CF) for OPC. The experimental factors are 48% of W/B and OPC and 2 kinds of concrete proportions. The target slump and air content are $150{\pm}25$ mm and $4.5{\pm}1.5$ %. For the results, the flowalility and air content of CF are less than OPC because it needs more superplasticiser and air-entraining agent. The temperature history of CF is lower than OPC about $6{\sim}10^{\circ}C$. For the strength properties, CF is less than OPC, but their gap is declined at 28 days. The strength of the specimens are ordered by standard curing, field cured specimens, and core specimens.

  • PDF

기계화시공에 의한 보수재료의 현장품질관리확립을 위한 실험적 연구 (An Experimental Study for Establishment of On-Site Quality Control of Repair Material by the mechanized construction)

  • 조봉석;장재봉;김용로;강석표;홍성윤;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.160-163
    • /
    • 2004
  • In domestic, various repair materials and method systems to keep up with these reinforced concrete deteriorated due to salt damage, carbonation, chemical decay et. developed and applied. However, on-site quality control of various repair materials and method systems isn't achieved desirably because it is depend completely on a men of experience' opinions above all else regardless of various on-site environments. In this background, mock up test with due regard to real on-site environments was performed to secure fundamental data for establishment of desirable on-site quality control. Mock up test using repair mortar analyzed from angles of construction methods, mechanical spraying pressures, W/M. Construction methods were designed manpower method and spraying method, spraying pressures were designed 32, 42, 52 psi, W/M were designed 14.4, 15.4, $16.4\%$. And compressive strength, Chloride ion diffusion coefficient, bond strength, SEM. of mock up test specimens were evaluated. In conclusion, we confirmed excellency of mechanical spraying pressures, fined extremely excellency of condition of spraying pressure 42 ps, W/M $14.4\%$ within this study. therefore the results of this study will be useful to provide fundamental data for establishment of desirable on-site quality control.

  • PDF

고성능 콘크리트의 Mock-Up 시험에 의한 수축특성 분석 (Analysis on Shrinkage Properties of High Performance Concrete According to Mock-Up Test)

  • 고경택;김호림;류금성;황인성;김도겸;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.545-548
    • /
    • 2004
  • This paper is to investigate the shrinkage properties of high performance concrete (HPC) with mixture adjustment by using mock-up specimens. HPC with mixture adjustment needed a higher dosage of SP agent due to fluidity reduction and a larger dosage of AE agent due to the reduction of air content. Setting time of HPC with mixture adjustment exhibited earlier than that of control HPC by as much as 6 hours. HPC with mixture adjustment gained more than 70MPa of compressive strength. Autogenous shrinkage of Control HPC was found to be $-340\times40^{-6}$ at 49days when the expansion value by thermal effect was excluded and HPC with mixture adjustment $-175\times10^{-6}$, which was the half of the value of control HPC. Drying shrinkage of center section of HPC with mixture adjustment showed similar tendency with autogenous shrinkage because of no internal moisture movement, while surface section had larger drying shrinkage. The specimen embedded with reinforcing bar had smaller deformation caused by confinement of reinforcing bar.

  • PDF

연행 공기량이 해양콘크리트의 동결융해 및 염화물 확산특성에 미치는 영향 (The Effect of Entrained Air Contents on the Properties of Freeze-thaw Deterioration and Chloride Migration in Marine Concrete)

  • 박상준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권5호
    • /
    • pp.161-168
    • /
    • 2008
  • 해양콘크리트의 대표적인 내구성 열화요인이라 할 수 있는 동결융해나 염해의 경우는 콘크리트내의 공극특성에 따라 침투 및 확산특성이 크게 상이하게 되는데, 이는 동결융해저항성 확보를 목적으로 사용되고 있는 AE제의 종류나 사용량 그리고 그의 경시변화 특성 등과 매우 밀접한 관계가 있다. 따라서 본 연구에서는 굳지않은 콘크리트의 목표 공기량을 각각 4~6%와 8~10%로 계획하여 실내시험을 실시한 후, 모의부재에서는 4~6%를 대상으로 평가하였다. 실험결과, 경화콘크리트의 공기량은 재령 7일에서 각각 2.5~5.2%, 재령 28일에서는 각각 2.4~5.1%정도로서 비빔직후 목표공기량의 절반수준인 것으로 나타났고, 동결융해 반복에 따른 스케일량은 목표공기량 8~10%의 경우가 4~6%에 비해 미미한 수준에서 다소 유리한 것으로 평가되었다. 한편, 모의부재에서 채취한 코어공시체의 동결융해 및 염화물 확산특성에서는 동일배합조건의 실내시험 결과에 비해 다소 불리한 것으로 나타났는데, 실내실험 결과에 비해 동결융해는 106%, 염화물 확산계수는 160% 수준인 것으로 나타났다.