• Title/Summary/Keyword: Mock-Up

Search Result 810, Processing Time 0.031 seconds

Development of the Maintenance Process Based on Graphic Simulation for the Parts of the Equipment at the outside of the MSM′s Workspace in a Hot Cell (그래픽 전산모사를 이용한 핫셀 사각지역 내 장치부품 유지보수공정 개발)

  • 이종열;김승현;송태길;박병석;윤지섭
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.55-64
    • /
    • 2003
  • In this study, the maintenance process by the servo manipulator has been developed for the parts of the equipment, which we unable to reach out by the Master-Slave Manipulator(MSM) in a hot cell. To do this, a virtual mock-up is implemented using the iか prototyping technology. Using this mock-up, the workspace of the manipulators in the hot cell and the operator's view through the wall-mounted lead glass have been analyzed. In addition, the path planning of the servo manipulator using the collision detection function of the virtual mock-up has been established. From these, the maintenance process for the parts of the equipment, which are located at the outside of the MSM's workspace using the servo manipulator has been proposed and verified through the graphic simulation. It is revealed that the proposed remote maintenance process of the equipment can effectively be used in the real hot cell operation. It is also believed that the implemented virtual mock-up of the hot cell can effectively be applied in analyzing the various hot cell operation and enhancing the reliability and safety in a hot cell remote handling for the spent fuel management.

  • PDF

A Study on Mechanical Properties of High Strength Concrete Performed by Full Scaled Mock-up Test (1:1 실부재 Mock-up Test를 통한 고강도 콘크리트의 역학적 특성에 관한 연구)

  • Moon, Hyung-Jae;Seok, Won-Kyun;Park, Soon-Jeon;Lee, Joo-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.981-984
    • /
    • 2008
  • The super tall building above 100 floors is required that each floor's height is more than 4 meters, and each core wall's thickness is more than 60cm. Therefore, for the successive accomplishment of super tall building, the full scale mock-up test was required. The test results are as follows; Real strength of core wall was satisfied with design strength at 28 days regardless of types of strength, and according to the consolidation effect, lower part's strength was a little higher than upper part's strength. Lateral force of HSC was evaluated with max. $4.5ton/m^2$, and hydration temperature of mock-up test was evaluated that maximun heat of central part revealed about $80^{\circ}C$ at 70MPa and $65^{\circ}C$ at 50MPa, and, the difference between inner and outter part revealed about $30^{\circ}C$ at 70MPa and $12^{\circ}C$ at 50MPa. Also, no crack by hydration temperature was not shown on the surface.

  • PDF

An XML-based Digital Mock-Up System for Heterogeneous Multi-CAD Assembly (XML을 이용한 이기종 CAD 조립체 DMU시스템의 설계)

  • Song, In-Ho;Chung, Sung-Chong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.6 s.261
    • /
    • pp.635-643
    • /
    • 2007
  • As many engineers and technicians are involved in the design process of large scale and/or complex products, there are a lot of miss matches and interferences due to designers' faults and several kinds of CAD systems. Recently, CAD systems are applied to verify and check the assembly process. Digital Mock-Up(DMU) system, a tool to build a virtual mock-up in the design stage, has been used to prevent the interferences and miss matches during precision design processes. Using the virtual assembly tool, engineers are able to design precision and interference free parts without physical mock-ups. Instead of a single CAD source, several CAD systems are used to design a complex product. Several organizations are involved in the distributed design environment for heterogeneous multi-CAD assembly. XML and the lightweight CAD file are proposed for the multi-CAD assembly. XML data contains hierarchy of the heterogenenous multi-CAD assembly. STEP PDM schema and STEP ISO 10303-28 formations are applied to construct the XML data. The lightweight CAD file produced from various CAD files through ACIS kernel and InterOp not only contains mesn, B-Rep and topological data, but also is used to visualize CAD data and to verify dimensions. Developed system is executed on the desktop computers. It does not require commercial CAD systems to visualize 3D assembly data. Real-time interference and fitness checks, dimensional verification, and design and assembly verification are performed on the developed system. Assembly of heterogeneous models for a car is conducted to verify the effectiveness of the developed DMU system on the Internet.

A Tunnel Mock-up Test and Numerical Analysis on Steel Fiber Reinforced Shotcrete (강섬유 보강 숏크리트의 터널모형실험 및 수치해석적 검증)

  • You, Kwang-Ho;Jung, Ji-Sung;Park, Yeon-Jun
    • Tunnel and Underground Space
    • /
    • v.18 no.2
    • /
    • pp.107-117
    • /
    • 2008
  • In this study, the failure and deformation characteristics of steel fiber reinforced shotcrete (SFRS) which is a primary tunnel support was investigated to find out ground-support mutual behavior. To this end, a mock-up of a tunnel was made and experimented with the conditions of lateral earth pressure coefficient 0.5 and 1.0. During the tests, 11 hydraulic cylinders were used for loading. for better simulation of the lateral earth pressure effect, these cylinders were controlled separately by two groups; crown and side wall. Meanwhile, the deformation of shotcrete was measured by 11 LVDTs. Backfill material was also used fur better load transfer from hydraulic cylinders to shotcrete. For the validation of the mock-up test results, 3D numerical analysis is carried out. To do numerical analysis under the same condition as a mock-up test, the load history curve which was obtained during the test was tried to be simulated using an individual FISH routine in the numerical analysis.

Evaluation of Filling Performance of Steel Concrete Panel (SCP) Mock-up Member with Low-binder based High-fluidity Concrete (저분체 기반 고유동 콘크리트의 Steel Concrete Panel Mock-up 부재 충전 성능 평가)

  • Park, Gi Joon;Park, Jung Jun;Kim, Sung Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.4
    • /
    • pp.477-483
    • /
    • 2019
  • Recently, precast type SCP modules are being used instead of PSC structures in order to reduce the construction period and costs of special structures such as nuclear power plants and LNG storage tanks. The inside of the SCP module is connected with a stud for the integral behavior of the steel and concrete, and the use of high fluidity concrete is required. High fluidity concrete generally has a high content of binder, which leads to an increase in hydration heat and shrinkage, and a problem of non-uniform strength development. Therefore, in this study, fluidity and passing performance of high fluidity concrete according to material properties are investigated to select optimum mix design of low binder based high fluidity concrete. Mechanical properties of high fluidity concrete before and after pumping are examined using pump car. The filling performance of SCP mock-up members was evaluated by using high fluidity concrete finally.

Experiment on Reduction of Pollutants in Titanium Dioxide Photocatalytic Ventilation System (이산화티탄 광촉매 환기장치의 오염물질 저감 실험)

  • Song, Yong Woo
    • Land and Housing Review
    • /
    • v.13 no.2
    • /
    • pp.117-123
    • /
    • 2022
  • In this study, titanium dioxide photocatalyst was applied to the ventilation system to reduce particulate matter and nitrogen oxides (NOx), which are representative indoor harmful substances. A reaction device capable of installing an ultraviolet lamp was designed and manufactured so that the pollutant decomposition effect of the titanium dioxide photocatalyst identified through previous studies could be applied indoors. The reaction device was used on the indoor ventilation system and applied to the Mock-Up test. As a result of the Mock-up test, the NOx reduction performance according to the change in air volume once per hour and five times per hour was confirmed. As a result, it was confirmed that as the number of ventilation increases, the NOx reduction time decreases proportionally, and the reduction performance increases.

A Study on Stabilizing Method of Deployable Systems (전개구조시스템의 안정화 방법에 관한 연구)

  • Kim, Seung-Deog;Park, Sun-Kyeong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.1
    • /
    • pp.93-99
    • /
    • 2014
  • Deployable structure is a system on which the study is being actively performed in various fields including architecture field. However, There is little study which can enhance the practicality since the interpretation condition is difficult as the unstable structure in the architecture field. In this study, the Scissors system has been focused on among the Deployable structure. The structure was developed using the Scissors system and the Mock-up test was performed. Through this, the unfolding method was proposed and the practicability was surveyed through the specific design of the Test model. Also, the structure stability was reviewed through structure analysis of Mock-up test model. and stabilizing method was proposed.

Mock-up Test of Exposed Concrete Wall using Self Compacting Concrete (노출 구조물 벽체에 적용하기 위한 무다짐 콘크리트 실물모형 실험)

  • 김규동;이승훈;손유신;김한준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.561-566
    • /
    • 2002
  • Recently, high quality exposed concrete is needed to achieve high quality surface for outer wall of the building. In this study, to solve above characteristic of the exposed concrete we selected self compacting concrete(SCC) and compared with normal concrete. So, we developed the SCC mix design and performed the semi mock-up test. Through this result, we performed the pilot test and mock-up test to check surface of outer wall and to measure formwork pressure As a result because SCC is better than normal concrete with respect to flowability and seggregation resistance SCC is suit to a exposed concrete needed high quality surface for outer wall of the building.

  • PDF

An Experimental Study on the Mock-up Test of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form (내한제 및 단열거푸집을 이용한 한중콘크리트의 모의구조체 적용에 관한 실험 연구)

  • 김경민;손성운;김기철;오선교;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.663-668
    • /
    • 2002
  • In this paper, insulating effects and strength development of concrete placed at mock up model structure are discussed using anti freezing agent and insulating forms. According to test results, concrete containing 8% of anti freezing agent shows lower freezing temperature, earlier setting time and higher strength development than plain concrete. As for the temperature history of mock up structures, when plain concrete is placed at euro form, the temperature drops to -4${\circ}$ before early 24 hours, and when concrete containing anti freeze agent at euro form, it to -3${\circ}$ before early 24 hours. Nevertheless, when concrete containing anti freeze agent is placed at insulating form, it does not go below zero, and the concrete containing anti freeze agent enhances higher strength development.

  • PDF

Experimental Study of Remote Handling Performance for Pyroprocessing Facilities (파이로 공정장치의 원격 취급성에 관한 실험적 연구)

  • Yu, Seung-Nam;Kim, Sung-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.5
    • /
    • pp.524-530
    • /
    • 2012
  • In this study, it is performed that the assessment of feasibility of developed material processing facilities using tele-operation manipulator system for the pyroprocessing. To evaluate the performance of developed facilities using tele-operation system, several performance indices are considered as remote visibility, remote reachability and remote manipulability. These are applied to RHEM (Remote Handling Evaluation Mock-up) and digital mock-up system respectively. Through this approaches, several requirements for the system improvement are deduced and preliminary inspection for real system application is fully performed. Additionally, assembly and disassembly tasks for the repair of remote handling system are also examined remotely in RHEM and evaluated those performances.