Recently, precast type SCP modules are being used instead of PSC structures in order to reduce the construction period and costs of special structures such as nuclear power plants and LNG storage tanks. The inside of the SCP module is connected with a stud for the integral behavior of the steel and concrete, and the use of high fluidity concrete is required. High fluidity concrete generally has a high content of binder, which leads to an increase in hydration heat and shrinkage, and a problem of non-uniform strength development. Therefore, in this study, fluidity and passing performance of high fluidity concrete according to material properties are investigated to select optimum mix design of low binder based high fluidity concrete. Mechanical properties of high fluidity concrete before and after pumping are examined using pump car. The filling performance of SCP mock-up members was evaluated by using high fluidity concrete finally.
Keywords
High fluidity concrete; Low binder; Mock-up member; Filling performance;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 BS EN 12390-3 (2009). Testing hardened concrete-Part 3: Compressive strength of test specimens, Technical standard, British Standards Institution, England.
2 BS EN 12350-8 (2010). Testing fresh concrete-Part 8: Selfcompacting concrete-Slump-flow test, Technical standard, British Standards Institution, England.
3 BS EN 12350-10 (2010). Testing fresh concrete-Part 10: Selfcompacting concrete-L box test, Technical standard, British Standards Institution, England.
4 BS EN 12350-12 (2010). Testing fresh concrete-Part 12: Selfcompacting concrete-J ring test, Technical standard, British Standards Institution, England.
5 Jang, K. P. and Kwon, S. H. (2015). "Evaluation on pumpability of concrete considering variation of rheological property for before and after pumping." Proc. of the KCI Conf., KCI, pp. 353-354.
6 JSCE Concrete Committee (1999). Recommendation for Self-Compactiong Concrete, Report, JSCE Concrete Committee, Japan.
7 Kim, H. R., Cho, H. K., Kim, J. C. and Lee, K. C. (2014). "Prediction of pumping friction resistance coefficient in pipe influenced by concrete rheology properties." Journal of the Korea Institute of Building Construction, Vol. 14, No. 2, pp. 118-126.   DOI
8 Kim, J. H., Ji, N. Y. and Kim, H. J. (1998). "A comparative study on the composition of using materials through refering to the high fluidity concrete of Korea and Japan." Journal of the Architectural Institute of Korea Structure & Construction, Vol. 14, No. 12, pp. 111-118.
9 Kim, J. H., Lee, H. W., Lee, J. B., Kwak, S. S. and Noh, S. H. (2008). Development of SC structure and modularization technique for nuclear power plant, Technical Report, S05NJ08-C2008-00, Korea Hydro & Nuclear Power Co., Ltd.
10 Kim, J. R., Lee, W. H. and Kwak, H. G. (2017). "Determination of efficient shear stud spacing in Steel-Concrete Panel (SCP) considering local buckling behavior." Journal of the Computational Structural Engineering Institute of Korea, Vol. 30, No. 6, pp. 479-484.   DOI
11 Park, G. J., Kim, S. W., Park, J. J. and Lee, D. G. (2017a). "Evaluation of optimum mix proportion and filling performance of highfluidity concrete for SCP module charging." Journal of the Korea Academia-Industrial cooperation Society, Vol. 18, No. 3, pp. 452-459.
12 Park, G. J., Park, J. J., Kim, S. W., Lee, J. H. and Han, H. S. (2017b). "Effect of binder mixing ratio on the properties of high-fluidity concrete with low binders." Proceedings of the Korea Insititute for Structural Maintenance and Inspection, KSMI, Vol. 21, No. 1, pp. 466-467.
13 Shin, T. Y., Kim, J. H., Shin, D. K. and Hwang, Y. Y. (2016). "Filling ability of steel-plate concete." Proc. of the KCI Conf., KCI, Vol. 28, No. 1, pp. 433-434.
14 Yim, S. J., Lee, B. S. and Bang, C. J. (2013). "Experimental study of mock-up for modular of high-strength reinforcing bars to the nuclear power plant structures." Journal of Architectural Institute of Korea, Vol. 33, No. 2, pp. 615-616.