5kg $U_{3}O_{8}$ Batch Scale Mock-up Test for the Electrochemical Reduction of Spent Oxide Fuel (사용후핵연료의 전기화학적 금속전환을 위한 5kg $U_{3}O_{8}$ Batch 규모의 Mock-up 시험)

  • 오승철;허진목;홍순석;이원경;서중석;박승원
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.47-53
    • /
    • 2003
  • An electrochemical reduction technology which can reduce the decay heat, volume, and radioactivity of spent fuel by a factor of quarter through converting oxide type spent fuel to a metallic form in a molten salt was developed and tests in a scale of g (3- 40g $U_{3}O_{8}$ batch) have been carried out by Korea Atomic Energy Research Institute. In this research, the reaction apparatus in a scale of 5kg $U_{3}O_{8}$ batch was designed and manufactured for the mock-up test to obtain design data of the apparatus which will be used for the hot test in a scale of 20kg $U_{3}O_{8}$ batch. The electrochemical reduction behavior of $U_{3}O_{8}$ was analyzed regarding the operational factors and fresh $U_{3}O_{8}$ powder was metallized with a more than 99% yield verifying the process validity of electrochemical reduction process in a kg scale.

  • PDF

Engineering Properties of Concrete Mock-up Using Coal Gasification Slag as Fine Aggregate. (석탄가스화 발전슬래그를 잔골재로 사용한 콘크리트 Mock-up 부재의 공학적 특성)

  • Han, Jun-Hui;Lee, Young-Jun;Hyun, Seung-Yong;Han, Min-Cheol;Yoon, Ki-Won;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.159-160
    • /
    • 2018
  • In this study, the characteristics of the Mock-up test were reviewed to analyze the applicability of the coal gasification slag (CGS) from the integrated gasification combination Cycle (IGCC) to the concrete fine aggregate. The analysis shows that CGS and crushed sand mix is the best combination of CGS combined with about 50 % of CGS based on the effects of promoting liquidity and strength. This is expected to be a positive factor in securing the strength and flexibility of concrete given the optimal mix of CGS, and may also contribute to the improvement of quality.

  • PDF

A Performance Test Method of Waterproofing System to Evaluate the Responsiveness to the Movement of Box Culvert Structure for Underground Electronic Power Facility (Mock-Up Test Method of Waterproofing Layer to Response 10 mm Movement of Expansion Joint) (지하 전력구조물의 거동에 대한 방수층의 대응 성능 평가 방법 개발 (10 mm 거동 대응형 방수시스템 Mock-Up 시험 방법))

Evaluation of Fire Performance for High Strength Concrete Mock-up Column with Fiber by Unloaded Fire Test (비재하 내화시험에 의한 섬유혼입 고강도 콘크리트 Mock-up 기둥의 내화성능 평가)

  • Song, Young-Chan;Kim, Yong-Ro;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.97-100
    • /
    • 2009
  • Fire resistance properties and mechanical properties of high strength concrete mock-up column using organic fiber by KS F 2257 Methods of fire resistance test for elements of building construction and compression test was investigated for application of precast concrete column method of high rise building in this study. As a test result, it was appeared that ECC permanent form is available as fire resistance method of high strength concrete and new precast concrete construction method for facilitating construction of high rise building.

  • PDF

5kg $U_3O_8$/Batch Scale Mock-up Test for the Electrochemical Reduction of Spent Oxide Fuel (사용후핵연료의 전기화학적 금속전환을 위한 5kg $U_3O_8$/Batch 규모의 Mock-up시험)

  • 오승철;허진목;홍순석;이원경;서중석;박성원
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.358-362
    • /
    • 2003
  • An electrochemical reduction technology which can reduce the decay heat, volume, and radioactivity of spent fuel by a factor of quarter by converting oxide type spent fuel to a metallic form in a molten salt was developed and mock-up test in a 5kg $U_3O_8$/batch scale was carried out. The electrochemical reaction was analyzed regarding the operational factors. The research efforts was also concentrated on the apparatus development for a hot test. Fresh $U_3O_8$ powder was metallized with a more than 99% yield via this electrochemical technology and design data for the 20kg $U_3O_8$/batch scale apparatus were also obtained.

  • PDF

A Study on Mechanical Properties of High Strength Concrete Performed by Full Scaled Mock-up Test (1:1 실부재 Mock-up Test를 통한 고강도 콘크리트의 역학적 특성에 관한 연구)

  • Moon, Hyung-Jae;Seok, Won-Kyun;Park, Soon-Jeon;Lee, Joo-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.981-984
    • /
    • 2008
  • The super tall building above 100 floors is required that each floor's height is more than 4 meters, and each core wall's thickness is more than 60cm. Therefore, for the successive accomplishment of super tall building, the full scale mock-up test was required. The test results are as follows; Real strength of core wall was satisfied with design strength at 28 days regardless of types of strength, and according to the consolidation effect, lower part's strength was a little higher than upper part's strength. Lateral force of HSC was evaluated with max. $4.5ton/m^2$, and hydration temperature of mock-up test was evaluated that maximun heat of central part revealed about $80^{\circ}C$ at 70MPa and $65^{\circ}C$ at 50MPa, and, the difference between inner and outter part revealed about $30^{\circ}C$ at 70MPa and $12^{\circ}C$ at 50MPa. Also, no crack by hydration temperature was not shown on the surface.

  • PDF

A Tunnel Mock-up Test and Numerical Analysis on Steel Fiber Reinforced Shotcrete (강섬유 보강 숏크리트의 터널모형실험 및 수치해석적 검증)

  • You, Kwang-Ho;Jung, Ji-Sung;Park, Yeon-Jun
    • Tunnel and Underground Space
    • /
    • v.18 no.2
    • /
    • pp.107-117
    • /
    • 2008
  • In this study, the failure and deformation characteristics of steel fiber reinforced shotcrete (SFRS) which is a primary tunnel support was investigated to find out ground-support mutual behavior. To this end, a mock-up of a tunnel was made and experimented with the conditions of lateral earth pressure coefficient 0.5 and 1.0. During the tests, 11 hydraulic cylinders were used for loading. for better simulation of the lateral earth pressure effect, these cylinders were controlled separately by two groups; crown and side wall. Meanwhile, the deformation of shotcrete was measured by 11 LVDTs. Backfill material was also used fur better load transfer from hydraulic cylinders to shotcrete. For the validation of the mock-up test results, 3D numerical analysis is carried out. To do numerical analysis under the same condition as a mock-up test, the load history curve which was obtained during the test was tried to be simulated using an individual FISH routine in the numerical analysis.

A Study on Stabilizing Method of Deployable Systems (전개구조시스템의 안정화 방법에 관한 연구)

  • Kim, Seung-Deog;Park, Sun-Kyeong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.1
    • /
    • pp.93-99
    • /
    • 2014
  • Deployable structure is a system on which the study is being actively performed in various fields including architecture field. However, There is little study which can enhance the practicality since the interpretation condition is difficult as the unstable structure in the architecture field. In this study, the Scissors system has been focused on among the Deployable structure. The structure was developed using the Scissors system and the Mock-up test was performed. Through this, the unfolding method was proposed and the practicability was surveyed through the specific design of the Test model. Also, the structure stability was reviewed through structure analysis of Mock-up test model. and stabilizing method was proposed.

Mock-up Test of Exposed Concrete Wall using Self Compacting Concrete (노출 구조물 벽체에 적용하기 위한 무다짐 콘크리트 실물모형 실험)

  • 김규동;이승훈;손유신;김한준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.561-566
    • /
    • 2002
  • Recently, high quality exposed concrete is needed to achieve high quality surface for outer wall of the building. In this study, to solve above characteristic of the exposed concrete we selected self compacting concrete(SCC) and compared with normal concrete. So, we developed the SCC mix design and performed the semi mock-up test. Through this result, we performed the pilot test and mock-up test to check surface of outer wall and to measure formwork pressure As a result because SCC is better than normal concrete with respect to flowability and seggregation resistance SCC is suit to a exposed concrete needed high quality surface for outer wall of the building.

  • PDF

A Study on Concentration Change of Volatile Organic Compounds; VOCs by using Mock-up Test (실물실험을 통한 개별 VOC의 농도변화에 관한 연구)

  • Kim Chang-Nam;Lee Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.487-495
    • /
    • 2005
  • Recently, due to the airtightness of buildings or the misuse of building materials, we have been witness SHS (Sick House Syndrome) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. As a result of this situation, we went to restrict the TVOC (Total Volatile Organic Compound) and formaldehyde. But these guidelines concentrated on only TVOC although TVOC are consist of many individual VOC. Therefore, in this study, we will look about concentration change of VOCs (Volatile Organic Compounds) by using Mock-up test. As result of test, the concentration of four individual VOC (Benzene, Toluene, Ethylbenzene, Styrene) showed quitely low level after 7 days. On the other hand the concentration of Xylene and formaldehyde showed low level after 14 days.