• Title/Summary/Keyword: Mock Up

Search Result 802, Processing Time 0.034 seconds

International Test Mock-up of the Self-Heating of Cement Developed using a Reducing Slag (환원슬래그를 이용하여 개발된 자기발열 시멘트의 해외 Mock-up Test 관한 연구)

  • Min, Tae-Beom;Choi, Hyun-Kuk;Kim, Hyeong-Cheol;Kim, Jae-Young;An, Dong-Hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.228-229
    • /
    • 2017
  • MOCK-UP TEST was conducted in the extreme region of the cement which was researched and developed by using the reducing slag Experimental results show that the basic properties (air volume, slump) are improved compared with the specimens using Mongolian cement. The compressive strength achieved the target strength (target strength: age 3day: 7MPa, age 7day 14MPa) and the hydration heat was about 8 ℃ higher than that of Mongolian cement products. Therefore, it is considered that the cement powders developed by our company showed the strength of concrete due to high hydration heat even at extreme temperatures.

  • PDF

Pyroshock measurement results of satellite mock-up for launch vehicle (발사체 목업(Mock-up) 위성의 파이로 충격 측정 결과)

  • Youn, S.H.;Jeong, H.K.;Seo, S.H.;Jang, Y.S.;Yi, Y.M.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.363-366
    • /
    • 2006
  • In general, pyrotechnic shock or pyroshock is generated during the operation of separation devices, which use explosives, such as pyrobolt, puronut, purocutter, linear shape charge, and so on. During the flight of launch vehicle, pyroshock is mainly produced at the events of satellite separation, fairing separation and stage separation. In this paper, characteristics of pyroshock are introduced in the first place and measured shock result data at the UMR of satellite mock-up during the separation tests of satellite and fairing are suggested. These results are compared with the suggested pyroshock test specification of satellite, and it finally confirms that the specification is reasonable for the qualification of satellite against pyroshock.

  • PDF

Study on Temperature History and Compressive Strength of Mock-up Concrete Considering Seasonal Change (매스콘크리트의 계절에 따른 온도이력과 압축강도에 관한 실험)

  • Kim Young-Joo;Gong Min-Ho;Kim Kwang-Ki;Yang Dong-Il;Pack Moo-Young;Jung Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.89-92
    • /
    • 2005
  • Our country has experienced variations in temperature as belong to the area of the continental climate that shows four significant seasons. These occur quality of construction. As the hydration of cement processes, the strength of concrete is developed. In order to improve the quality of concrete, various conditions including temperature and humidity should be maintained appropriately and concrete itself should be cured sufficiently This paper is basic experiment for estimating influence of strength by seasonal mock-up concrete's heat of hydration and estimate relationship of compressive strength development by curing temperature. And show basic document as quality control.

  • PDF

A Study on selection of the Type and the Technique for the Hazard Analysis of the Train Control System(mock-up) (열차제어시스템(mock-up)의 위험원 분석을 위한 Type과 Technique의 선정에 대한 연구)

  • Han, Chan-Hee;Lee, Young-Soo;Ahn, Jin;Jo, Woo-Sic
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.614-622
    • /
    • 2008
  • It has been studying actively that the process and the methodology for the safety security of the system suggested from international standards and domestic/abroad materials in Korea. However, these process & methodology can generate a lot of errors and deficiencies because the system is applied without considering the system characteristics and its scope (such as hardware, software, interface, etc.). Therefore, the type is defined as the safety process with the basis on general development process in this study, the potential hazards of the mock-up system which is developed are extracted thorough selecting a technique according to each type. In addition to it, the effect is compared and analyzed with various technique selection by each phase of the development process.

  • PDF

Staged Damage Detection of a RC Mock-up Structure by Artificial Neural Network (인공신경망을 이용한 RC Mock-up 구조물의 단계별 손상탐지)

  • Kwon, Hung-Joo;Kim, Ji-Young;Yu, Eun-Jong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.676-679
    • /
    • 2011
  • 인공신경망(Artificial Neural Network)을 이용하여 RC Mock-up 구조물의 손상위치 및 손상정도를 단계적으로 추정하였다. 대상 구조물은 가진실험을 통하여 구조물의 응답을 취득하고 구조물식별기법(Structural System Identification)을 통하여 구조물의 동특성을 찾았다. 유한요소해석프로그램을 사용하여 동특성이 계측치와 가장 유사한 기본해석모델을 만든 후 이 기본해석모델을 이용하여 학습데이터를 생성하였다. 기존 인공신경망을 이용한 손상탐지를 개선하고자 본 연구에서는 인공신경망 학습데이터를 분석하였고 효과적인 손상탐지를 위하여 학습데이터를 가공하였다. 가공된 학습데이터를 사용하여 단계별 손상탐지를 실시하였고 기존 손상탐지 방법보다 좋은 결과를 유도하였다.

  • PDF

A Study on the Properties of Recycled Aggregate Concrete applied to Mock-up (Mock-up에 적용한 재생골재콘크리트의 특성 연구)

  • Shim Jong-Woo;Lee Sea-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.93-96
    • /
    • 2005
  • In this study, Mock-up was manufactured using recycled aggregate concrete and then analyzed with respect to physical properties. Finally, the applicability of recycled aggregates as constructional aggregates was reviewed by practically putting recycled aggregates concrete into construction. Right after mixing, the slump of recycled-aggregates concrete showed decreased slump as time goes by because the surface mortar of recycled aggregates absorbed the mix water with time passing. The air contents of recycled-aggregates concrete overall increase a little due to the effect of surface mortar of the aggregates. For strengths, the strengths of recycled aggregate concrete tended to decrease from the proportion of 30$\%$ to 100$\%$.

  • PDF

Mock-up Test on the Reduction of Drying Shrinkage Crack in Structural Concrete (구조체 콘크리트의 건조수축 균열저감에 관한 Mock-up 실험)

  • Yoon Seob;Song Seung Heon;Han Min Cheol;Kim Kyeong Hwan;Jong Young Hee;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.393-396
    • /
    • 2005
  • This paper presents the results of drying shrinkage of concrete using shrinkage-reducingadmixture(DSRA) studied by the authors through mock-up test. DSRA is proportioned by expansive admixture and shrinkage reducing agent(SRA). Flowing concrete method is also applied to assist the concrete to reduce drying shrinkage by decreasing water content at the same time. The use of EA and SRA does not affect fluidity, bleeding and setting time. Compressive strength of concrete using EA along with SRA exhibited less than that of plain concrete. However, The compressive strength with combination of EA-SRA along with flowing concrete method shows comparable to that of plain concrete. The application of developed method can contribute to reducing drying shrinkage by as much as 30-40$\%$ compared with that of plain concrete.

  • PDF

Evaluation of Fire Performance for High Strength Concrete Mock-up Column with Fiber by Unloaded Fire Test (비재하 내화시험에 의한 섬유혼입 고강도 콘크리트 Mock-up 기둥의 내화성능 평가)

  • Song, Young-Chan;Kim, Yong-Ro;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.97-100
    • /
    • 2009
  • Fire resistance properties and mechanical properties of high strength concrete mock-up column using organic fiber by KS F 2257 Methods of fire resistance test for elements of building construction and compression test was investigated for application of precast concrete column method of high rise building in this study. As a test result, it was appeared that ECC permanent form is available as fire resistance method of high strength concrete and new precast concrete construction method for facilitating construction of high rise building.

  • PDF

Application of the Artificial Neural Network to Damage Evaluations of a RC Mock-up Structure (구조물 손상평가를 위한 인공신경망의 RC Mock-up 적용 평가)

  • Kim, Ji-Young;Kim, Ju-Yeon;Yu, Eun-Jong;Kim, Dae-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.687-691
    • /
    • 2010
  • 구조물의 건전도를 평가하기 위해 상시 구조물 계측을 이용한 Structural Health Monitoring (SHM) 시스템을 적용하게 된다. SHM 시스템의 궁극적 목적은 계측된 데이터를 이용하여 구조물의 손상위치 및 손상정도를 분석하여 거주자에게 유지관리정보와 대처요령 신속하게 제공하는 것이다. 따라서 본 연구에서는 구조물의 손상탐지를 위해 인공신경망(Artificial Neural Network)을 도입한 알고리즘을 수립하고, 이를 3층 실대 RC Mock-up 구조물에 적용하여 성능을 평가하였다. 먼저 인공신경망의 학습을 위해 구조해석 프로그램을 이용하여 구조물의 손상에 따른 동적특성 변화 데이터베이스를 구축하였다. 그리고 학습된 인공망에 실제 구조물에서 추출한 동특성의 변화를 입력하여 손상탐지를 실시하였다. 이를 통해 인공신경망의 학습방법, 학습데이터의 정규화 방법 등을 규명하고 인공신경망을 이용한 손상탐지의 효과를 분석하였다.

  • PDF

The Rebar Modulation Method in the Area of the Nuclear Power Plant Structures (원전구조물 부위별 철근모듈화 방안 연구)

  • Lee, Byung-Soo;Bang, Chang-Joon;Kim, Hun Jin;Lim, Sang-Joon;Park, Jong-Hyuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.15-16
    • /
    • 2013
  • Because of the complicated shape and the overcrowded arrangement of rebar, there are some problems in applying the rebar modulation for the Nuclear Power Plant Structures. In order to resolve these problems, we have been studying the rebar modulation method applying techniques of the high strength rebar for NPP Structure. After reviewing the rebar drawing of the NPP structures and performing the mock-up test, the rebar modulation method in the various area of the NPP Structure has been established. I will introduce this method and the future plan of the research.

  • PDF