• Title/Summary/Keyword: Mobius

Search Result 47, Processing Time 0.025 seconds

SIP-based Session Management Architecture between Gateways and Servers on Mobius IoT Platform (모비우스 IoT 플랫폼에서 게이트웨이와 서버간 SIP 기반 세션 관리 구조)

  • Kim, Daesoon;Min, Kyoungwook;Roh, Byeong-hee
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.13 no.4
    • /
    • pp.90-99
    • /
    • 2017
  • The service structure of the Mobius IoT platform, which has been developed on the basis of the oneM2M standard, connects servers and gateways directly to exchange data using HTTP or MQTT. Such structure may cause problems not to operate IoT services safely. In this paper, we propose an effective structure to manage sessions between gateways (or devices) and server using SIP safely and stably. In addition, we provide the way to implement the proposed method on Mobius IoT platform. To verify the operation of the proposed method, we actually implement the proposed method on Mobius IoT platform, and construct a testbed for a typical IoT application service environment with SIP servers. The results of the experiment show that the proposed method works normally, and it can contribute to the stable operation of IoT services.

A study on the Distinctive construction of Korean Men's Traditional Trousers (남자 한복바지의 구성특성에 관한 연구)

  • Kim, Eun-Jung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.7 s.144
    • /
    • pp.909-917
    • /
    • 2005
  • Based on the theory that formation of Korean Men's Traditional Trousers is related to Mobius strip, this study researches correlation between distinctive construction of Korean Men's Traditional Trousers and historical background based on old documents and restoration. Distinctive construction of Korean Men's Traditional Trousers are as follows. First, Korean Men's Traditional Trousers is manufactured just like Principle of Mobius strip that the square is twisted once, considering its materials' conditions. Second, Korean Men's Traditional Trousers, manufactured larger, feature cubic effect and twisted formative beauty because its waist and ankle parts are tightened with bands. Third, Korean Men's Traditional Trousers, composed of big Sapok and small Sapok in oblique, are suitable for active play due to its high functionality.

A Fast Computation Method of Power Ground Plane Impedance using the Mobius Transform (Mobius변환을 이용한 전력접지층 임피던스의 빠른 계산방법)

  • Suh Youngsuk;Kim In-Sung;Song Jae-Sung;Eum Tae-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.1
    • /
    • pp.41-44
    • /
    • 2005
  • A new method to reduce the computation time in power/ground-plane analysis is proposed. The existing method using the two dimensional infinite series summation take a lot of computation time. The proposed method is based on the approximation of impedance in the frequency domain through the Mobius transform. This method shows the good accuracy and the high speed in computing. In the case of impedance calculation for 9'x4' board, the proposed method takes 0.16 second of computing time whereas the existing method takes 2.2 second. This method can be applied to the analysis and design of power/ground-plane that need a lot of computation steps.

Quantitative Evaluation of Patient Positioning Error Using CBCT 3D Gamma Density Analysis in Radiotherapy

  • Lee, Soon Sung;Min, Chul Kee;Cho, Gyu Suk;Han, Soorim;Kim, Kum Bae;Jung, Haijo;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.149-155
    • /
    • 2017
  • Radiotherapy patients should maintain their treatment position as patient setup is very important for accurate treatment. In this study, we evaluated patient setup error quantitatively according to Cone-Beam Computed Tomography (CBCT) Gamma Density Analysis using Mobius CBCT. The adjusted setup error to the $QUASAR^{TM}$ phantom was moved artificially in the superior and lateral direction, and then we acquired the CBCT image according to the phantom setup error. To analyze the treatment setup error quantitatively, we compared values suggested in the CBCT system with the Mobius CBCT. This allowed us to evaluate the setup error using CBCT Gamma Density Analysis by comparing the planning CT with the CBCT. In addition, we acquired the 3D-gamma density passing rate according to the gamma density criteria and phantom setup error. When the movement was adjusted to only the phantom body or 3 cm diameter target inserted in the phantom, the CBCT system had a difference of approximately 1 mm, while Mobius CBCT had a difference of under 0.5 mm compared to the real setup error. When the phantom body and target moved 20 mm in the Mobius CBCT, there are 17.9 mm and 13.5 mm differences in the lateral and superior directions, respectively. The CBCT gamma density passing rate was reduced according to the increase in setup error, and the gamma density criteria of 0.1 g/cc/3 mm has 10% lower passing rate than the other density criteria. Mobius CBCT had a 2 mm setup error compared with the actual setup error. However, the difference was greater than 10 mm when the phantom body moved 20 mm with the target. Therefore, we should pay close attention when the patient's anatomy changes.

TOPOLOGICAL CHARACTERIZATIONS OF CERTAIN LIMIT POINTS FOR MOBIUS GROUPS

  • Hong, Sung-Bok;Kim, Han-Doo
    • Bulletin of the Korean Mathematical Society
    • /
    • v.38 no.4
    • /
    • pp.635-641
    • /
    • 2001
  • A limit point p of a Mobius group acting on$ B^m$ is called a concentration point if for every sufficiently small connected open neighborhood of p, the set of translates contains a local basis for the topology of p. For the case of two generator Schottky groups acting on $B^2$, we give characterizations for several different kinds of limit points.

  • PDF

Calculation of Stress Intensity Factor in Arbitrarily Shaped Plane Crack under Uniform Pressure Loading (일정 압력에 의한 3차원 평면균열에서의 응력확대계수 계산)

  • An, Deuk-Man
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.117-122
    • /
    • 2000
  • In this paper the stress intensity factor under uniform pressure in the arbitrarily-shaped plane crack configuration transformed elliptic crack by Mobius mapping are determined. Using Dyson's formula Boussinesq-Papkovich potentials for mode I deformation are constructed. In the example the stress intensity factors are approximately calculated by least square method.

  • PDF

UNITARY ANALOGUES OF A GENERALIZED NUMBER-THEORETIC SUM

  • Traiwat Intarawong;Boonrod Yuttanan
    • Communications of the Korean Mathematical Society
    • /
    • v.38 no.2
    • /
    • pp.355-364
    • /
    • 2023
  • In this paper, we investigate the sums of the elements in the finite set $\{x^k:1{\leq}x{\leq}{\frac{n}{m}},\;gcd_u(x,n)=1\}$, where k, m and n are positive integers and gcdu(x, n) is the unitary greatest common divisor of x and n. Moreover, for some cases of k and m, we can give the explicit formulae for the sums involving some well-known arithmetic functions.

Implementation of IoT Sensors Network Using Mobius Platform (모비우스 플랫폼을 이용한 IoT 센서 네트워크 구현)

  • Chang, Woo Young;Lee, Yong Cheol;Kang, Jeong Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.211-218
    • /
    • 2017
  • In this study, we implemented IoT Sensor Network using Mobius Platform and implemented four kinds of Z-wave sensors applicable to smart home service to verify its performance. The 12 common service functions (CSF) provided by Mobius enable application services including status monitoring of sensors to be implemented quickly. The standard service procedures and protocols have eliminated the design process of the system and shortened the meeting time for establishing protocol between application software developer, gateway developer and sensor developer, and discussion time for adjustment of opinion. We confirmed that the application service based on the implemented sensor network and the implementation of IoT sensor can shorten the development schedule, and confirmed that most of the products purchased in the market can be accommodated without change. We hope that such speediness and openness will be able to meet the demands of various services and contribute to expanding services and creating new markets.

Assessment for the Utility of Treatment Plan QA System according to Dosimetric Leaf Gap in Multileaf Collimator (다엽콜리메이터의 선량학적엽간격에 따른 치료계획 정도관리시스템의 효용성 평가)

  • Lee, Soon Sung;Choi, Sang Hyoun;Min, Chul Kee;Kim, Woo Chul;Ji, Young Hoon;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • For evaluating the treatment planning accurately, the quality assurance for treatment planning is recommended when patients were treated with IMRT which is complex and delicate. To realize this purpose, treatment plan quality assurance software can be used to verify the delivered dose accurately before and after of treatment. The purpose of this study is to evaluate the accuracy of treatment plan quality assurance software for each IMRT plan according to MLC DLG (dosimetric leaf gap). Novalis Tx with a built-in HD120 MLC was used in this study to acquire the MLC dynalog file be imported in MobiusFx. To establish IMRT plan, Eclipse RTP system was used and target and organ structures (multi-target, mock prostate, mock head/neck, C-shape case) were contoured in I'mRT phantom. To verify the difference of dose distribution according to DLG, MLC dynalog files were imported to MobiusFx software and changed the DLG (0.5, 0.7, 1.0, 1.3, 1.6 mm) values in MobiusFx. For evaluation dose, dose distribution was evaluated by using 3D gamma index for the gamma criteria 3% and distance to agreement 3 mm, and the point dose was acquired by using the CC13 ionization chamber in isocenter of I'mRT phantom. In the result for point dose, the mock head/neck and multi-target had difference about 4% and 3% in DLG 0.5 and 0.7 mm respectively, and the other DLGs had difference less than 3%. The gamma index passing-rate of mock head/neck were below 81% for PTV and cord, and multi-target were below 30% for center and superior target in DLGs 0.5, 0.7 mm, however, inferior target of multi-target case and parotid of mock head/neck case had 100.0% passing rate in all DLGs. The point dose of mock prostate showed difference below 3.0% in all DLGs, however, the passing rate of PTV were below 95% in 0.5, 0.7 mm DLGs, and the other DLGs were above 98%. The rectum and bladder had 100.0% passing rate in all DLGs. As the difference of point dose in C-shape were 3~9% except for 1.3 mm DLG, the passing rate of PTV in 1.0 1.3 mm were 96.7, 93.0% respectively. However, passing rate of the other DLGs were below 86% and core was 100.0% passing rate in all DLGs. In this study, we verified that the accuracy of treatment planning QA system can be affected by DLG values. For precise quality assurance for treatment technique using the MLC motion like IMRT and VMAT, we should use appropriate DLG value in linear accelerator and RTP system.