• 제목/요약/키워드: Mobile X-ray

검색결과 79건 처리시간 0.03초

이동형 X선촬영에서 공간산란선량 분포 측정 (Measurement of the Scattered Spatial Dose Distribution for the Mobile X-ray Radiography)

  • 권덕문;박명환;남효덕
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권1호
    • /
    • pp.23-26
    • /
    • 2001
  • The spatial distribution of the scattered dose for mobile X-ray radiography is measured. The scattered X-ray exposures at the radius of 50, 100 and 150 cm from the irradiation center are 880, 180 and $50\;{\mu}R$, respectively. This scattered X-rays can be reduced to 60% by inserting the portable shield made by 0.4 mm copper sheet sandwiched in two plywoods.

  • PDF

16kW 회전 Aonde형 모노블럭 X-선 발생장치 (A 16kw Rotating Anode type Monoblock X-ray Generator)

  • 오준용;김연충;김학성
    • 전력전자학회논문지
    • /
    • 제11권2호
    • /
    • pp.97-103
    • /
    • 2006
  • 본 논문은 회전형 대용량 진단 X-선 발생장치를 모노 블록 형태로 설계, 병원의 모바일 진단장치나, 산업용 X-선 장치로에 적용이 가능한 16kW급 회전 Anode형 모노블럭 X-선 발생장치에 관한 연구이다. 본 장치는 X-선 발생을 위해 회전 Anode 형의 X-선관을 사용하였고, X-선관의 Anode의 회전을 위한 로터를 구동할 수 있는 로터 구동회로를 추가 하였다. 고주파 고전압용 인버터에는 IGBT(600V/300A)소자를 100kHz로 고주파 스위칭 함으로서 고전압 변압기를 비롯한 고전압 발생부의 크기와 무게를 최소화하였다. 또한, 기존의 16kW급 대용량 진단 X-선 발생장치를 X-선관과 고전압부를 일체화한 모노블록 형태로 설계, 제작하여 부하변동에 따른 X-선 관전압과 관전류의 동작특성을 실험을 통하여 입증하였다.

진단용방사선발생장치의 안전관리에 관한 규칙 개정에 따른 이동형 방사선검사의 개선방안 (Improvement Way for Mobile X-ray Examinations by Rule Revision about Safety Management of Diagnosis Radiation Occurrence System)

  • 최준구;김경수;김병기;안남준;김형선;김상건;임시은
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권1호
    • /
    • pp.53-59
    • /
    • 2007
  • 방사선종사자와 환자 및 보호자의 안전을 위해 개정된 진단용방사선발생장치의 안전관리 규칙이 2006년 2월 10일 공포되었다. 이 규칙에는 중환자실, 수술실, 응급실을 제외한 곳의 방사선검사 시 반드시 방사선방어 용칸막이를 설치하도록 하고 있다. 이 연구의 목적은 이동형 진단용방사선발생장치를 안전하게 관리하여, 방사선으로 인한 위해를 방지하고, 환자 및 보호자들로부터 발생될 수 있는 고객 불만사항들을 최소화 하는데 있다. 조사대상은 병실 이동형 방사선검사환경과 본원의 의료정보시스템(KIS) 및 의료영상전송시스템(PACS)의 통계 데이터를 조사하였다. 그리고 병실 이동형 방사선검사 시 환자 상태 및 감염 등 관련 정보를 조사하여 자료화 하였다. 자료 분석을 통한 이동형 방사선검사에 대한 개정된 규칙을 적용할 경우 고려되는 문제점은 공간적인 측면에서의 제약, 운영적인 측면에서의 인력 및 비용, 업무적인 측면에서 환자 및 보호자 만족도저하 등의 문제가 예상되었다. 따라서 위와 같은 문제를 해결하기 위해 다인병실의 검사를 제한하고, 각 병동에 있는 치료실을 이용하여 검사하도록 하였다. 그 결과 전체 병실 이동형 방사선검사율이 50% 가까이 감소하였고, 거동이 양호한 환자의 병실 이동형 방사선검사율도 85% 이상 감소하였다. 이 결과는 새로운 법 규정에 따라 예상되는 인력, 비용, 고객만족도 저하의 문제들을 해결할 수 있는 대안이 될 수 있었다. 또한 병실 이동형 방사선검사로 인한 환자 및 보호자를 방사선노출로부터 보호하고, 검사로 인한 주위 환자 및 보호자의 불편을 최소화하는데 의의가 있다.다. 6. 성별에 따른 질환의 종류는 남자가 여자보다 pulmonary nodule이 많았고, 여자는 남자보다 cardiomegaly와 tortous aorta, scoliosis가 더 많았다. 7. 연령에 따른 질환의 종류는 35세 미만이 다른 연령대보다 scoliosis가 많았고, $40{\sim}49$세는 CP angle blunting, $35{\sim}39$세는 pulmonary nodule, 50세 이상은 cardiomegaly와 tortous aorta가 많았다. 수 있으리라고 사료된다.이었고(p<0.01) 포장에 대해서는 주택형태에 따라 농가나 아파트에 거주하는 주부가 단독주택이나 연립주택에 거주하는 주부보다 더 나쁘게 평가하는 경향이었다. (p<0.05) (9) 조사대상주부들은 시판제품의 가장 개선해야 할 점으로 위생성(37.0%), 가격(23.8%), 포장(15.6%), 맛(11.1%), 저장성(10.1%) 및 색(2.4%) 등의 순으로 지적하였고 주부의 거주지에 따라 대도시에 거주할수록 위생성을, 농어촌에 거주할수록 가격을 가장 개선해야 할 점으로 보는 경향이었다. (p<0.05)3.2%는 채소에는 cholesterol이 함유되어 있지 않으므로 채식이 건강에 좋다고 하였다. 또한 질병치료에 유효한 채소는 당근 등 42가지, 질병을 유발시키는 채소는 고사리 등 10종을 지적하였으며 이들은 과학적 증명이 가능하거나 민간요법으로 전해지고 있는 내용이다. 이상과 같이 덕성여자대학교 평생교육원에 다니는 주부의 채소 소비 형태에 대하여 살펴보았는데

  • PDF

깊은 공핍층을 가지는 우주항공용 촬상소자의 3 차원 특성 분석 (Three-Dimensional Characterizing Analysis of Astronomic CCDs with a deep depletion)

  • Kim, M. H.
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 하계학술발표회
    • /
    • pp.228-229
    • /
    • 2000
  • Buried channel JET-X CCDs (Joint European X-ray Telescope Charge Coupled Devices: EEV CCD12) with a deep depletion have been analyzed to provide an optimized condition for a charge storage and transfer. A maximum charge capacity has been found for the supplementary narrow channel by considering the potential distribution as a function of a mobile charge. Analysis for the depletion edges of JET-X CCDs have been successfully performed, showing good agreement with the depths estimated from X-ray detection efficiency measurements [1]. (omitted)

  • PDF

SVM on Top of Deep Networks for Covid-19 Detection from Chest X-ray Images

  • Do, Thanh-Nghi;Le, Van-Thanh;Doan, Thi-Huong
    • Journal of information and communication convergence engineering
    • /
    • 제20권3호
    • /
    • pp.219-225
    • /
    • 2022
  • In this study, we propose training a support vector machine (SVM) model on top of deep networks for detecting Covid-19 from chest X-ray images. We started by gathering a real chest X-ray image dataset, including positive Covid-19, normal cases, and other lung diseases not caused by Covid-19. Instead of training deep networks from scratch, we fine-tuned recent pre-trained deep network models, such as DenseNet121, MobileNet v2, Inception v3, Xception, ResNet50, VGG16, and VGG19, to classify chest X-ray images into one of three classes (Covid-19, normal, and other lung). We propose training an SVM model on top of deep networks to perform a nonlinear combination of deep network outputs, improving classification over any single deep network. The empirical test results on the real chest X-ray image dataset show that deep network models, with an exception of ResNet50 with 82.44%, provide an accuracy of at least 92% on the test set. The proposed SVM on top of the deep network achieved the highest accuracy of 96.16%.

인공지능을 활용한 C-Arm에서 수술용 거즈 검출을 위한 데이터셋 구축 및 검출모델 적용에 관한 연구 (A Study on the Dataset Construction and Model Application for Detecting Surgical Gauze in C-Arm Imaging Using Artificial Intelligence)

  • 김진엽;황호성;이병주;최용진;이강석;김호철
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권4호
    • /
    • pp.290-297
    • /
    • 2022
  • During surgery, Surgical instruments are often left behind due to accidents. Most of these are surgical gauze, so radioactive non-permeable gauze (X-ray gauze) is used for preventing of accidents which gauze is left in the body. This gauze is divided into wire and pad type. If it is confirmed that the gauze remains in the body, gauze must be detected by radiologist's reading by imaging using a mobile X-ray device. But most of operating rooms are not equipped with a mobile X-ray device, but equipped C-Arm equipment, which is of poorer quality than mobile X-ray equipment and furthermore it takes time to read them. In this study, Use C-Arm equipment to acquire gauze image for detection and Build dataset using artificial intelligence and select a detection model to Assist with the relatively low image quality and the reading of radiology specialists. mAP@50 and detection time are used as indicators for performance evaluation. The result is that two-class gauze detection dataset is more accurate and YOLOv5 model mAP@50 is 93.4% and detection time is 11.7 ms.

방사성폐기물 드럼 비파괴 검사를 위한 X-ray 장비 평가 (Evaluation of X-ray System for Nondestructive Testing on Radioactive Waste Drums)

  • 박종길;맹성준;이연의;황태원
    • 방사성폐기물학회지
    • /
    • 제6권3호
    • /
    • pp.189-203
    • /
    • 2008
  • 원전 부지에 저장중인 방사성폐기물을 처분장에 인도하기 전에 폐기물의 물리 화학적 특성이 인수기준에 적합한지를 검사해야 한다. 검사하는 방법 중 비파괴 검사방법에 대해 조사하였는데, 조사결과 X-ray를 이용한 비파괴 방법을 적용하면 인수검사 항목 중 '드럼내 내용물 검사', '유리수 및 채움율 정량검사'를 할 수 있는 것으로 나타났다. 본 논문에서는 먼저 X-ray 장비의 원리와 시스템 선정 시 고려해야 할 사항들에 대해 간략하게 살펴 본 후 X-ray 장비를 이용하여 검사해야 할 드럼들의 특성을 분석하였다. 분석한 특성들은 드럼의 종류, 드럼의 규격, 드럼내 내용물의 종류 등이었고 이들 특성자료를 이용하여 검사에 필요한 X-ray 소요에너지를 계산하였다. 계산 결과 드럼 크기가 320 l 이하인 드럼을 검사하기 위한 소요에너지는 3 MeV 이하로 나타났으며 경제성 및 실현가능성 측면에서 450 keV 장비와 3 MeV 장비를 조합하거나 단독으로 사용하는 것이 바람직하고 이 때 450 keV 장비를 이용하여 검사가 가능한 저밀도 드럼 수는 2006년 12월 저장기준으로 42,327 드럼, 3 MeV 장비를 이용하여 검사가 가능한 드럼 수는 18,105 드럼으로 나타났다. 검사를 수행하는 주체, 장비 구매 방안 등에 따라 4가지 검사 시나리오를 수립하고 이에 대해 경제성 및 적용 가능성을 분석한 결과 최적의 검사시나리오는 인수기준, 처리 및 처분장 인도에 대한 폐기물 발생자의 정책 등에 영향을 받는 것으로 나타났다. 예를 들어, '유리수', '채움율'에 대한 정량분석과 ‘내용물 확인’을 모두 해야 할 경우에는 밀도가 상대적으로 낮은 폐기물이 담겨있는 ‘저밀도 드럼’의 검사를 위해 450 keV 이동형 장비 2대를 구입하여 자체 검사하고 ‘고밀도 드럼’은 외주로 검사하는 것이 바람직할 수 있다. 반면‘내용물 확인’만을 비파괴 검사항목으로 할 경우에는 450 keV 급 이동형 장비 1대면 연간 13,000 드럼을 검사할 수 있는 것으로 나타났다.

  • PDF

의료기기 고장 발생의 원인 분석을 통한 효과적인 보수유지 방법의 개선 (Effective Maintenance of Medical Device through System Failure Analysis)

  • 강훈희;김종순;김서확;허수진
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.106-107
    • /
    • 1998
  • To minimize the failure rate of medical devices, the maintenance records for general X-ray, R/F X-ray, mobile X-ray, artificial dialyzer, ventilator, and automatic chemistry analyzer was analysed with regard to the cause of the failure. The parts responsible for the most frequent system failure was then worked intensively during the preventive maintenance. After this procedure, the faliure of the systems in a month decreased from 1.8 on average to 0.3.

  • PDF

Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구 (A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index)

  • 김재인;이양섭;장동수;정민철;배승호;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF