• Title/Summary/Keyword: Mixed gas

Search Result 1,368, Processing Time 0.031 seconds

Formation and Dissociation Processes of Gas Hydrate Composed of Methane and Carbon Dioxide below Freezing

  • Hachikubo, Akihiro;Yamada, Koutarou;Miura, Taku;Hyakutake, Kinji;Abe, Kiyoshi;Shoji, Hitoshi
    • Ocean and Polar Research
    • /
    • v.26 no.3
    • /
    • pp.515-521
    • /
    • 2004
  • The processes of formation and dissociation of gas hydrates were investigated by monitoring pressure and temperature variations in a pressure cell in order to understand the kinetic behavior of gas hydrate and the controlling factors fur the phase transition of gas hydrate below freezing. Gas hydrates were made kom guest gases ($CH_4,\;CO_2$, and their mixed-gas) and fine ice powder. We found that formation and dissociation speeds of gas hydrates were not controlled by temperature and pressure conditions alone. The results of this study suggested that pressure levels at the formation of mixed-gas hydrate determine the transient equilibrium pressure itself.

Preparation and Characterization of Mixed-matrix Membranes Containing MIL-100(Fe) for Gas Separation (MIL-100(Fe)를 함유한 혼합기질막(mixed-matrix membranes, MMMs)의 제조 및 기체 투과 특성 연구)

  • Song, Hye Rim;Nam, Seung Eun;Hwang, Young Kyu;Chang, Jong San;Lee, U Hwang;Park, You In
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.432-438
    • /
    • 2013
  • Mixed-matrix membranes (MMMs) containing MIL-100(Fe), a MOF type, were fabricated in this study. MMMs up to 30 wt% MOF loading were prepared, and their gas permeabilities were tested. $H_2$, $CO_2$, $O_2$, $N_2$, and $CH_4$ gas permeabilities increased with the MOF loading, while $SF_6$, the largest kinetic diameter in this study, exhibited reduction of gas permeability with the loading. Ideal gas selectivity of $N_2/SF_6$ improved by 40% as compared with pure polyimide membrane, suggesting the proposed MMMs were suitable for $N_2/SF_6$ separation.

Improvement of Long-term Stability in $SnO_2$ Based Gas Sensor for Monitoring Offensive Odor

  • Park, Jong-Hun;Kim, Kwang-Ho
    • The Korean Journal of Ceramics
    • /
    • v.6 no.3
    • /
    • pp.304-308
    • /
    • 2000
  • WO$_3$/SnO$_2$ceramics has been suggested as an effective sensing material for monitoring offensive odor or pollutant gases. This work was focussed on improving long-term stability, which has been a principal problem generally taking place in SnO$_2$semiconductor gas sensor. Miniaturized thick film gas sensors were fabricated by screen printing technique. Two types of sensor materials, W doped SnO$_2$and WO$_3$mixed SnO$_2$, were comparatively investigated on those long-term stability and sensitivites to several gases. Small amount of W doping(0.1 mol%) into SnO$_2$largely improved the long-term stability. The W(0.1 mol%) doped SnO$_2$gas sensor had higher sensitivities to both acetone and alcohol compared with WO$_3$(5 wt%) mixed SnO$_2$gas sensor. On the contrary, WO$_3$(5 wt%) mixed SnO$_2$gas sensor showed more superior sensitivity to cigarette smoke due to larger W content.

  • PDF

Thermodynamic promoter effects on the phase equilibrium of BFG(Blast Furnace Gas) hydrate (촉진제 첨가에 따른 철강공정 배기가스 하이드레이트 상평형 영향)

  • Lee, Bo Ram;Sa, Jeong-Hoon;Park, Da-Hye;Kwak, Kye-Hoon;Lee, Kun-Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.125.1-125.1
    • /
    • 2011
  • $CO_2$ separation from a flue gas by using the gas hydrate technology was suggested by Kang et al. They reported phase equilibrium conditions of mixed gases composed of $CO_2$ and N2 with THF as a thermodynamic promoter. In this study, we reported the phase equilibrium conditions of a mixed gas which had a realistic composition of the blast furnace gas (BFG) emitted from the steel-making process. The phase equilibrium measurements were done by using the "continuous" QCM method, and the results demonstrate that this method is efficient and as accurate as the conventional temperature search method.

  • PDF

Evaluation of Greenhouse Gas Emissions for Life Cycle of Mixed Construction Waste Treatment Routes (혼합 건설폐기물 처리경로별 전과정 온실가스 발생량 평가)

  • Kim, Da-Yeon;Hwang, Yong-Woo;Kang, Hong-Yoon;Moon, Jin-Young
    • Resources Recycling
    • /
    • v.31 no.1
    • /
    • pp.56-64
    • /
    • 2022
  • Construction waste is generated at a rate of approximately 221,102 tons/day in Korea. In particular, mixed construction waste generates approximately 24,582 tons/day. The other components were recycled by 98.9%. The amount of greenhouse gas emissions from the waste was 17.1 million tons of CO2 equaling 2.3% of the total greenhouse gas emissions. To reduce greenhouse gas emissions, reducing the environmental impact is becoming increasingly important. However, appropriate treatment must first be established, as mixed construction waste is also increasing. Thus, an effective plan is urgently needed because it is frequently segregated and sorted by the landfill and incinerated. In addition, there is an urgent need to prepare various effective recycling methods rather than a simple treatment. Therefore, this study analyzed the environmental impact of the treatment of mixed construction waste by calculating greenhouse gas emissions. As a result, the highest greenhouse gas generation occurred during the incineration stage. Moreover, the optimal method to reduce greenhouse gas emissions is recycling and energy recovery from waste. In addition, the amount of greenhouse gas generated during energy recovery from the waste stage was the second highest. However, greenhouse gas emissions can be reduced by using waste as energy to reduce fossil fuel consumption. In addition, for the transportation stage, the optimal reduction plan is to minimize the amount of greenhouse gas emissions by setting the optimal distance and applying biofuel and electric vehicle operations.

Enhancement of Gas Transfer Efficiency in an Intravascular Lung Assist Device using Blood Substitutes (혈관내의 폐보조장치에서 혈액대용물질을 사용한 기체전달 효율향상)

  • 김기범;박재관;권대규;정경락;이삼철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.391-399
    • /
    • 2003
  • Intravascular oxygenation represents an attractive. alternative support modality for therapy originated with acute respiratory distress syndrome(ARDS). However. the clinical study concluded that more gas exchange was needed for intravascular oxygenation to be clinically effective in ARDS treatment. In this study, we tried to enhance gas exchange on the VIVLAD using microencapsulation of hemoglobin and perfluorocarbon emulsion(PFC emulsion). Blood gas measurements were performed by collecting blood samples from the arterial and venous sides of the circuit, and processing them in a blood/gas analyzer. The function of hemosome. blood/hemosome mixed solution. and blood/PFC emulsion mixed solution were tested by an oxygen dissociation curve using a blood/gas analyzer. As a result, it was shown that the oxygen transfer of hemosome and blood/hemosome mixed solution were higher than that of whole blood. Also. it showed that the carbon dioxide transfer of whole blood/PFC emulsion mixed solution was higher than that of others. Therefore, we determined that hemosome and PFC emulsion could increase oxygen transfer and carbon dioxide transfer. respectively.

A Study on the Flow Characteristics of the Flue Gas Recirculation with the Change of Venturi Tube Shape (벤튜리관 형상에 따른 배기가스 재순환 유동 특성에 관한 연구)

  • Ha, Ji Soo;Shim, Sung Hun;Kim, Dae Yeon
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.1
    • /
    • pp.12-18
    • /
    • 2019
  • Exhaust gas recirculation method is widely used among various methods for reducing nitrogen oxides in automobile engines and incinerators. In the present study, the computational fluid dynamic analysis was accomplished to derive the optimal location of air nozzle exit position by changing its position in a venturi tube for the maximum flue gas recirculation effect. In addition, the flue gas recirculation characteristics with a cone at the exit of air nozzle was elucidated with flue gas recirculation flow rate ratio and mixed gas exit temperature. When the air nozzle exit position was changed from the start position (z = 0) to the end position (z = 0.6m) of the exhaust gas recirculation exit pipe, the change of streamline and temperature distribution in the venturi tube was observed. The exhaust gas recirculation flow rate and the average temperature at the mixed gas exit position was quantitatively compared. From the present study, the optimal location of air nozzle exit position for the maximum flue gas recirculation flow rate ratio and maximum mixed gas exit temperature is z = 0.15m (1/4L). In addition, when the cone is installed at the outlet of the air nozzle, the velocity of the air nozzle outlet is increased, the flue gas recirculation flow rate was increased by about 2 times of the flow rate without cone, and the mixed gas exit temperature is increased by $116^{\circ}C$.

Identification of Gas Mixture with the MEMS Sensor Arrays by a Pattern Recognition

  • Bum-Joon Kim;Jung-Sik Kim
    • Korean Journal of Materials Research
    • /
    • v.34 no.5
    • /
    • pp.235-241
    • /
    • 2024
  • Gas identification techniques using pattern recognition methods were developed from four micro-electronic gas sensors for noxious gas mixture analysis. The target gases for the air quality monitoring inside vehicles were two exhaust gases, carbon monoxide (CO) and nitrogen oxides (NOx), and two odor gases, ammonia (NH3) and formaldehyde (HCHO). Four MEMS gas sensors with sensing materials of Pd-SnO2 for CO, In2O3 for NOX, Ru-WO3 for NH3, and hybridized SnO2-ZnO material for HCHO were fabricated. In six binary mixed gas systems with oxidizing and reducing gases, the gas sensing behaviors and the sensor responses of these methods were examined for the discrimination of gas species. The gas sensitivity data was extracted and their patterns were determined using principal component analysis (PCA) techniques. The PCA plot results showed good separation among the mixed gas systems, suggesting that the gas mixture tests for noxious gases and their mixtures could be well classified and discriminated changes.

Combustion Characteristics of Methane/Oxygen Gas in Pre-mixed Swirl Flame (메탄/순산소 예혼합 화염의 선회 특성)

  • Choi, Won-Seok;Kim, Han-Seok;Cho, Joo-Hyeong;Kim, Yong-Mo;Ahn, Kook-Young;Woo, Ta-Kwan
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.1979-1983
    • /
    • 2008
  • The effects of carbon dioxide addition to oxygen have been investigated with swirl-stabilized premixed methane flame in a laboratory-scale pre-mixed combustor. The methane fuel and oxydant mixture gas ($CO_2$ and $O_2$) were mixed in a pre-mixer and introduced to the combustor through different degrees of swirl vanes. The flame characteristics were examined for different amount of carbon dioxide addition to the methane fuel and different swirl strengths. The effects of carbon dioxide addition and swirl intensity on the combustion characteristics of pre-mixed methane flames were examined using chemiluminescence techniques to provide information about flow field. The results show that the flame area increases at upstream of reaction zone because of increase in recirculation flow for increase in swirl intensity. The flame area is also increased at the downstream zone by recirculation flow because of increase in swirl intensity which results in higher centrifugal force. The OH and CH radical intensity of reaction zone decrease with carbon dioxide addition because the carbon dioxide plays a role of dilution gas in the reaction zone.

  • PDF

Gas Permeation Characteristics by Pebax/ZIF-9 Mixed Matrix Membrane (Pebax/ZIF-9 혼합막에 의한 기체투과 특성)

  • Yoon, Soong Seok;Hong, Se Ryeong
    • Membrane Journal
    • /
    • v.32 no.5
    • /
    • pp.325-335
    • /
    • 2022
  • In this study, zeolitic imidazolate framework-9 (ZIF-9) was synthesized and Pebax/ZIF-9 mixed membranes were prepared by varying the content in poly(ether-b-amide)-1657 (Pebax-1657), and then a single gas (N2, CO2) was permeated to investigate the gas permeation characteristics of the mixed membrane. As the ZIF-9 content incorporated into the pure Pebax membrane increased, the N2 permeability gradually decreased, and the CO2 permeability increased up to the Pebax/ZIF-9 3 wt% mixed membrane, and then decreased at the content thereafter. And among the mixed membranes, the Pebax/ZIF-9 3 wt% mixed membrane showed the highest selectivity of 69.3 by selectively accepting CO2 as the gate-opening phenomenon occurred for the polar gas, CO2. In addition, both the CO2 permeability and the CO2/N2 selectivity increased, resulting in the closest Robeson upper-bound.