• 제목/요약/키워드: Minimum-energy

검색결과 1,810건 처리시간 0.033초

Stability of superconductor by integration formula

  • Seol, S.Y.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권3호
    • /
    • pp.1-5
    • /
    • 2019
  • The superconductor stability theories are consistently described by the integral formula. If the defined stability function is a simple decreasing function, it becomes a cryogenic stability condition. If the stability function has a maximum value and a minimum value, and the maximum value is less than 0, then it is a cold-end recovery condition. If the maximum value is more than 0, it can be shown that the unstable equilibrium temperature, that is, the MPZ (minimum propagation zone) temperature distribution can exist. The MPZ region is divided into two regions according to the current ratio. At the low current ratio, the maximum dimensionless temperature is greater than 1, and at the relatively high current ratio, the maximum dimensionless temperature is less than 1. In order to predict the minimum quench energy, the dimensionless energy was obtained for the MPZ temperature distribution. In particular, it was shown that the dimensionless energy can be obtained even when the MPZ maximum temperature is 1 or more.

방전전극 재질과 최소점화에너지에 관한 실험 연구 (An Experimental Study on the Minimum Ignition Energy in Low Voltage Spark Discharge by Electrode Material)

  • 최상원
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.63-70
    • /
    • 2012
  • In the hazardous areas where explosive gases, vapor or mists exist, electrical apparatus and installations must be the explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, nine types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, non-incendive, powder filling, encapsulation, and special types. Among these types, the intrinsic safety has the construction which limit or by-pass igniting the electric energy using electronic devices. This type has lots of merits but at the same time requires a high-degree of technology. In this paper, we investigated several dominating factors which affect the minimum ignition energy; this energy plays a very important role in design and evaluation of the intrinsic safety type electrical apparatus. Electrode material, which is one of the most important factors, was intensively studied for the five sorts of material(Al, Cd, Mg, Sn, and Zn) with performing experiment in a low-voltage inductive circuit using IEC-type(International Electro-technical Commission) spark apparatus. The experimental results show that the minimum ignition energy of electrode material is varied: highest in Cd and lowest in Sn. We also confirmed the effect of electrode make-and-break speed.

무선 센서 네트워크에서 최소 전력 브로드캐스트 문제를 위한 최적화 알고리즘 (An Optimization Algorithm for Minimum Energy Broadcast Problem in Wireless Sensor Networks)

  • 장길웅
    • 한국통신학회논문지
    • /
    • 제37권4B호
    • /
    • pp.236-244
    • /
    • 2012
  • 무선 네트워크에서 최소 에너지 브로드캐스트 문제는 네트워크에 배치된 모든 노드가 브로드캐스팅과정에서 데이터 전송에 사용되는 에너지를 최소화하는 문제이다. 본 논문은 무선 센서 네트워크에서 최소 에너지 브로드캐스트 문제를 효과적으로 해결할 수 있는 메타휴리스틱 기법인 타부서치 알고리즘을 제안한다. 보다 효과적인 해 검색을 위해 제안된 알고리즘은 새로운 이웃해 생성방식과 복구함수를 적용한다. 제안된 알고리즘의 성능평가는 배치된 모든 노드로의 브로드캐스팅 시 전송 에너지와 알고리즘 실행시간 관점에서 기존의 알고리즘과 비교를 하였으며, 실험 결과에서 제안된 알고리즘이 최소 에너지 브로드캐스트 문제에 효과적으로 적용됨을 보여준다.

Study on transient performance of tilting-pad thrust bearings in nuclear pump considering fluid-structure interaction

  • Qiang Li;Bin Li;Xiuwei Li;Quntao Xie;Qinglei Liu;Weiwei Xu
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2325-2334
    • /
    • 2023
  • To study the lubrication performance of tilting-pad thrust bearing (TPTBs) during start-up in nuclear pump, a hydrodynamic lubrication model of TPTBs was established based on the computational fluid dynamics (CFD) method and the fluid-structure interaction (FSI) technique. Further, a mesh motion algorithm for the transient calculation of thrust bearings was developed based on the user defined function (UDF). The result demonstrated that minimum film thickness increases first and then decreases with the rotational speed under start-up condition. The influence of pad tilt on minimum film thickness is greater than that of collar movement at low speed, and the establishment of dynamic pressure mainly depends on pad tilt and minimum film thickness increases. As the increase of rotational speed, the influence of pad tilt was abated, where the influence of the moving of the collar dominated gradually, and minimum film thickness decreases. For TPTBs, the circumferential angle of the pad is always greater than the radial angle. When the rotational speed is constant, the change rate of radial angle is greater than that of circumferential angle with the increase of loading forces. This study can provide reference for improving bearing wear resistance.

지역별 기후에 따른 비주거 건축물 패시브 수준 단열기준 연구 (Study on Insulation Standards at Passive Level of Non-Residential Buildings by Regional Climate)

  • 김예원;유기형
    • 한국태양에너지학회 논문집
    • /
    • 제37권6호
    • /
    • pp.51-58
    • /
    • 2017
  • This study proposes an appropriate level of insulation standards by region through annual heating energy requirements according to regional climate. The reference buildings out of non-residential buildings approved by the energy saving design standard for buildings were derived in the previous study, in which the annual heating energy requirements for each building were as follows when the insulation standard for building members in four regions (Pyeongchang, Seoul, Gwang-ju, and Jeju) suggested by the energy saving design standard for buildings: $29.8kWh/m^2$ in Pyeongchang, $17.5kWh/m^2$ in Seoul, $14.4kWh/m^2$ in Gwangju, and $16.7kWh/m^2$ in Jeju. To satisfy the passive level of insulation standards for these buildings, in case that roof/floor of buildings in Pyeongchang and Seoul was $0.2W/m^2K$, the minimum window thermal transmittance should satisfy $0.9W/m^2K$ and the minimum wall thermal transmittance should satisfy $0.1W/m^2K$ in the case of Pyeongchang. On the other hand, the minimum window thermal transmittance should satisfy $1.5W/m^2K$ and the minimum wall thermal transmittance should satisfy $0.14W/m^2K$ in the case of Seoul. For Jeju regions, the minimum wall thermal transmittance should satisfy $0.34W/m^2K$ to meet the passive level of buildings. Based on the above results, the thermal transmittance of each member by region should take the outdoor climate condition of the region into consideration to satisfy the passive level of buildings.

MANET의 에너지 분산 소모를 위한 패킷 분산 라우팅 (A Packet Distribution Routing for Balancing Energy-Consumption in MANET)

  • 김동학;최용준;박희주;김종근
    • 정보처리학회논문지C
    • /
    • 제15C권2호
    • /
    • pp.79-86
    • /
    • 2008
  • MANET(Mobile Ad hoc Network)은 두 대 이상의 이동 무선 단말로 구성되는 네트워크로 단말의 한정된 에너지 때문에 많은 제한성을 가지게 된다. MANET에서 특정 노드들의 조기 에너지 소진은 네트워크 성능에 큰 영향을 줄 수 있다. 본 논문에서는 이에 대한 해결책으로 송, 수신지 사이에 가능한 많은 노드 비중첩 다중 경로를 구축하고, 각 경로상 노드가 가진 평균 에너지, 최소 에너지, 혹은 에너지 분산 값에 따라 다중 경로를 통해 패킷을 분산 전송한다. 에너지 정보 수집 방법을 크게 Static 방식과 Dynamic 방식으로 나누며, 수집하는 에너지 정보에 따라 Static-Average, Static-Minimum, Static-Variance, 그리고, Dynamic-Average, Dynamic-Minimum, Dynamic-Variance 등 6가지 방식으로 나누고, NS2 시뮬레이션을 통해 그 성능을 비교하고 평가한다.

최소 변형 에너지 밀도 기준에 의한 콘크리트 보의 균열전파에 관한 연구 (Study on Crack Propagation of Concrete beam under Mixed-Mode Loading by Minimum Strain Energy Density Failure Criterion)

  • 진치섭;이영호;신동익;오정민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.529-534
    • /
    • 1998
  • To find out an adequate failure criterion in two-dimensional linear elastic crack problems, finite element programs, SED, which determine stress intensity factors $K_I, K_{II}$, crack angle and peak load by the minimum strain energy density failure criterion were developed. In this program, the conventional quadratic isoparametric elements were used in all regions except the crack tip zone where triangular singular elements with 6 nodes were used. The results of SED were compared with the results of those which followed by the maximum circumferential tensile stress criteria and those by the maximum energy release rate criteria and those by Jenq and Shah`s experiments of the same geometry and material properties. The maximum energy release rate criteria were better close to those of the Jenq and Shah`s experiments than the maximum circumferential tensile stress criteria and the minimum strain energy density criteria.

  • PDF

테레프탈산의 분진 폭발특성에 관한 연구 (A Study on Explosion Characteristics of Terephthalic Acid)

  • 목연수;장성록
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.121-125
    • /
    • 2000
  • This study was executed by dust explosion experiment of terephthalic acid which was widely used for various purposes of food packing material and film etc. and the demand was rapidly increasing. The particle size and concentration of dust affected the minimum ignition energy largely and the lean concentration and the minimum ignition energy in the range of this study were obtained 50$g/m^3$ and 19mJ respectively. Minimum ignition energy was shown at the 4 and 5mm gap distance of discharge electrode, and when the gap distance was below 2mm the explosion could not generated although the sufficient energy was given. It was also found that the ignition energy decreased linearly with the decreasing of dust mean particle size.

  • PDF

3성분계 인화성 혼합가스의 최소점화에너지 측정에 관한 연구 (Measurement of Minimum Ignition Energy by Electrostatic Discharge for Flammable Ternary Gas Mixtures)

  • 최상원
    • 한국안전학회지
    • /
    • 제28권1호
    • /
    • pp.29-34
    • /
    • 2013
  • When flammable gases are mixed with air or oxygen in the explosion concentration range and are ignited by sufficiently large electrostatic discharge energy, they may explode causing severe disaster in workplace. The minimum ignition energy(MIE) of single gas-air mixtures has been already investigated by many research, but the MIE of mixtures of more than ternary gas mixture is not examined yet. The purpose of this study is to investigate the MIE of a ternary gas(methane, ethylene, hydrogen, propane) mixtures experimentally. The results of our experiment show that the ignition of a methane-ethylene-air, methane-hydrogen-air, methane-propane-air, ethylene-hydrogen-air, ethylene-propane-air and hydrogen-propane-air mixture due to electrostatic discharge energy primarily depends on that the mixture: the MIE decreases gradually with the increase of having the lower MIE than other mixture ratio in the normal atmospheric pressure.

마이크로그리드(MG)의 설계를 위한 에너지저장장치(ESS)의 최소용량산정 기법에 관한 연구 (A Study on the Method to Evaluate Minimum Capacity of Energy Storage System(ESS) for Micro-Grid Design)

  • 이재걸;신정훈;최영도;남수철;김태균
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.52-58
    • /
    • 2009
  • 본 논문에서는 마이크로그리드(Micro grid, MG)의 설계에서 필요로 되는 에너지저장장치(Energy storage system, ESS)의 최소설비용량을 산정할 수 있는 확률론적 방법론을 제시하였다. ESS기술은 아직까지 경제성 측면에서 매우 높은 설비비용이 필요로 되기 때문에 적정 설비규모를 산정하는 것과 MG의 안정적인 운영을 위해서 최소 설비용량에 대한 가이드라인의 제시가 필요로 된다. 본 논문에서 제시한 방법론은 Non-dispatchable 발전원 출력의 간헐성과 모든 발전기의 고장정지확률을 고려하여 MG가 자체적인 에너지 Self balancing을 유지할 수 있는 ESS의 최소설비용량을 산정할 수 있는 것을 특징으로 한다.