• 제목/요약/키워드: Minimum effective dose

검색결과 73건 처리시간 0.022초

최소 효과 용량을 정하는 축차 검정법 (Parametric Sequential Test Procedure to Find the Minimum Effective Dose)

  • 박수진;김동재
    • 응용통계연구
    • /
    • 제22권5호
    • /
    • pp.1033-1046
    • /
    • 2009
  • 신약 개발 연구 또는 임상시험에서 개발된 약이 0용량 대조군과 비교해 유의한 효과 차이가 있어 신체에 반응할 수 있는 최소 복용량을 결정하는데, 이 최소 복용량을 최소 효과 용량(Minimum Effective Dose; MED)이라 한다. 이 논문에서는 최소 효과 용량을 확인하기 위하여 업데이티드 대조군을 이용한 모수적 축차 검정법을 제안하였다. 또한 모의 실험을 통하여 기존의 검정법과 제안한 검정법의 실험유의수준(experimental significance level)과 검정력(power)을 비교하였다.

Nonparametric Procedures for Finding Minimum Effective Dose in a One-Way Layout

  • Kim, Hyeonjeong;Kim, Dongjae
    • Communications for Statistical Applications and Methods
    • /
    • 제9권3호
    • /
    • pp.693-701
    • /
    • 2002
  • When the lowest dose level compared with zero-dose control has significant difference in effect, it is referred as minimum effective dose (MED). In this paper, we discuss several nonparametric methods for finding MED using updated rank at each sequential test step in small sample size and suggest new nonparametric procedures based on placement. Monte Carlo Simulation is adapted to compare power and Familywise Error Rate(FWE) of the new procedures with those of discussed nonparametric tests for finding MED.

Nonparametric Procedure for Identifying the Minimum Effective Dose with Ordinal Response Data

  • Kang, Jongsook;Kim, Dongjae
    • Communications for Statistical Applications and Methods
    • /
    • 제11권3호
    • /
    • pp.597-607
    • /
    • 2004
  • The primary interest of drug development studies is identifying the lowest dose level producing a desirable effect over that of the zero-dose control, which is referred as the minimum effective dose (MED). In this paper, we suggest a nonparametric procedure for identifying the MED with binary or ordered categorical response data. Proposed test and Williams' test are compared by Monte Carlo simulation study and discussed.

다중 그룹 상황에서의 최소 효과 용량을 정하는 비모수적 검정법 (Nonparametric Procedures for Finding the Minimum Effective Dose in Each of Several Group)

  • 배수현;김동재
    • Communications for Statistical Applications and Methods
    • /
    • 제19권1호
    • /
    • pp.33-45
    • /
    • 2012
  • 신약 개발 연구 또는 임상시험에서 개발된 약이 0용량 대조군과 비교해 효과 차이가 있는 가장 작은 용량을 최소 효과 용량(MED)이라 한다. 본 논문에서는 다중 그룹 상황에서 동시적(simultaneous)으로 각 각 그룹의 최소 효과 용량을 확인하기 위하여 위치(placement)에 기초한 비모수적 방법을 제시하였다. 또한 Monte Carlo 모의실험을 통하여 기존에 제시된 검정법과 본 논문에서 제안한 검정법의 검정력(power)과 FWE(Family-wise Error Rate)를비교하였다.

X-band EPR dosimetry using minimum mass of tooth enamel for use in radiological accidents

  • Jae Seok Kim;Byeong Ryong Park;Han Sung Kim;In Mo Eo;Jaeryong Yoo;Won Il Jang;Minsu Cho;HyoJin Kim;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.123-131
    • /
    • 2024
  • Electron paramagnetic resonance (EPR) dosimetry for a tooth from an individual exposed is well known as retrospective dosimetry in radiological accidents. A major constraint of the conventional X-band tooth-EPR dosimetry is the necessity to extract the tooth of the exposed patient for dose assessment. In this study, to conduct the dose assessments of exposed patients through part-extraction of tooth enamel, the minimum detectable dose (MDD) of the tooth enamel was evaluated based on the amount of mass. Further, a field test was conducted via intercomparison using various dose assessment methods to verify the feasibility of X-band tooth-EPR dosimetry using the minimum mass of tooth enamel. The intercomparison results demonstrated that effective dose determination via X-band tooth-EPR dosimetry is reliable. Consequently, it was determined that the minimum mass of tooth enamel required to evaluate an absorbed dose above 0.5 Gy is 15 mg. Thus, EPR dosimetry using 15 mg of tooth enamel can be applied in the triage and initial medical response stages for patients exposed during radiological accidents. This approach represents an advancement in managing radiological accidents by offering a more efficient and less invasive method of dose assessment.

선량 환산 관례를 이용한 생애유효선량 및 라돈피폭 위험도 예측: 대학 강의실 라돈농도 중심으로 (Prediction for the Lifetime Effective Dose and Radon Exposure Risk by using Dose Conversion Convention: Base on the Indoor Radon Concentration of Lecture Room in a University)

  • 이재승;권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권6호
    • /
    • pp.243-249
    • /
    • 2018
  • The indoor radon concentration was measured in the lecture room of the university and the radon concentration was converted to the amount related to the radon exposure using the dose conversion convention and compared with the reference levels for the radon concentration control. The effect of indoor radon inhalation was evaluated by estimating the life effective dose and the risk of exposure. To measure the radon concentration, measurements were made with a radon meter and a dedicated analysis Capture Ver. 5.5 program in a university lecture room from January to February 2018. The radon concentration measurement was carried out for 5 consecutive hours for 24 hours after keeping the airtight condition for 12 hours before the measurement. Radon exposure risk was calculated using the radon dose and dose conversion factor. Indoor radon concentration, radon exposure risk, and annual effective dose were found within the 95% confidence interval as the minimum and maximum boundary ranges. The radon concentration in the lecture room was $43.1-79.1Bq/m^3$, and the maximum boundary range within the 95% confidence interval was $77.7Bq/m^3$. The annual effective dose was estimated to be 0.20-0.36 mSv/y (mean 0.28 mSv/y). The life-time effective dose was estimated to be 0.66-1.18 mSv (mean $0.93{\pm}0.08mSv$). Life effective doses were estimated to be 0.88-0.99 mSv and radon exposure risk was estimated to be 12.4 out of 10.9 per 100,000. Radon concentration was measured, dose effective dose was evaluated using dose conversion convention, and degree of health hazard by indoor radon exposure was evaluated by predicting radon exposure risk using nominal hazard coefficient. It was concluded that indoor living environment could be applied to other specific exposure situations.

X-선 단순 Series 촬영 시 피폭 선량 평가 (Assessment of Radiation Dose Due to X-Ray Simple Series Examinations)

  • 강은보;황인철;신운재
    • 한국방사선학회논문지
    • /
    • 제8권2호
    • /
    • pp.81-88
    • /
    • 2014
  • 진단영상의학에서 일반영상촬영의 경우 각각의 부위를 연속(series)촬영으로 검사하는 경우가 대부분이다. 그러나 환자선량권고량(DRL)의 경우 각 부위의 전후(AP)방향과 측면(lateral)자세의 촬영 측정값만이 설정되어있는 것이 현실이다. 병원에서는 환자의 연속 촬영에 의해 누적 선량이 발생되며, 이는 환자선량권고량(DRL)과 누적된 피폭선량을 비교할 수 없거나, 과소평가할 수 있다. 본 연구에서 각 부위별 연속촬영의 누적선량을 측정한 결과, 조사야에 포함된 경우 입사표면선량(ESD)을 유효선량으로 변환하면 공중의 선량한도(Individual dose)의 최대 38.06%에서 최소 0.23%까지 측정되었다. 그리고 조사야에 포함되지 않은 각 부위의 입사표면선량(ESD)을 유효선량(Effective dose)으로 변환한 경우 공중의 선량한도(Individual dose)의 최대 5%에서 최소 0.04%까지 측정되었다. 연구결과 각 부위별 연속촬영에서 입사표면선량(ESD)이 많이 증가하는 것을 알 수 있다. 따라서 병원에서는 환자선량권고량(DRL)을 구체적으로 설정할 필요가 있으며, 불필요한 검사를 줄이기 위해 환자 촬영 order의 세분화가 필요하다고 판단된다. 또한, 여러 부위의 검사에서는 정확한 조사야의 필요성이 강조된다.

대학 내 학습공간과 공동 생활공간에 대한 실내 라돈 농도 측정과 유효선량 산출 (Indoor Radon Levels and Effective Dose Estimation in Learning and Common Living Space of University)

  • 김정수
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.329-334
    • /
    • 2018
  • 라돈은 자연방사성원소로 호흡을 통해 인체에 피폭된다. 본 연구에서는 2017년 6월 1일부터 2017년 8월 28일까지 3개월 동안 A대학의 8개 건축물에 대해 실내 라돈농도를 측정하여 비교하였고, 연간 유효선량을 도출하였다. 본 연구에서 A대학의 건축물 Hall G와 Hall F의 라돈농도는 각각 $81Bq/m^3$, $14Bq/m^3$로 나타났으며, 전체 조사 건축물의 평균 실내 라돈농도는 $41.63Bq/m^3$로 나타났다. 대학 내 학습공간과 생활공간에 대한 연간 유효선량 환산치의 평균은 0.40 mSv/y이며 최대 연간 유효선량은 0.78 mSv/y, 최소 연간 유효선량은 0.13 mSv/y로 나타났다. 학교는 학생들이 오랜 시간 머무르는 공간이므로 건축물에 대한 적절한 환기와 관리를 통해 실내라돈 농도를 낮추는 것이 라돈에 대한 자연방사선 피폭을 낮추는 방법이다.

핵의학검사의 방사성의약품 소아투여량 공식 별 투여량 및 유효선량 비교 (Comparing of the Administered Activities and the Effective Dose of the Various Pediatric Dose Formulas of Nuclear Medicine)

  • 길종원
    • 한국융합학회논문지
    • /
    • 제8권8호
    • /
    • pp.147-154
    • /
    • 2017
  • 본 연구는 소아핵의학검사에 사용하는 다양한 소아투여량 공식의 투여량(MBq)과 유효선량(mSv)을 산출 비교하여 적정투여량의 기준을 위한 기초자료를 제공하고자 한다. 연구는 2가지 방사성의약품($^{99m}Tc$-MDP와 $^{99m}Tc$-Pertechnetate)의 성인투여량을 기준으로 5가지 소아투여량공식(Clark법, Area법, Webster법, Young법, Solomon(Fried)법) 간 투여량과 유효선량을 비교하였다. 소아투여량 산출에 기준이 되는 성인투여량은 정준기, 이명철 '핵의학'에 수록된 값을 사용하였으며, 유효선량 산출을 위한 방사성의약품의 방사능당 유효선량(mSv/MBq)은 ICRP 80과 UNSCEAR 2008 보고서에 수록된 값을 사용하였다. 연구결과 Young법이 산출량이 가장 적으며 다른 공식과의 차이는 최소 1.7배-최대 3.4배였다. $^{99m}Tc$-MDP의 공식 간 투여량 차이는 최대 309.9MBq, 유효선량은 3.76mSv, $^{99m}Tc$-Pertechnetate는 최대 154.9MBq, 유효선량은 5.50mSv였다. 소아투여량 공식 간 투여량뿐만 아니라 유효선량도 차이가 크기 때문에 의료방사선의 최적화를 위한 적정투여량 소아산출법이 개발되어야 한다.

심장 전기생리학 검사 시 조건 변화에 따른 환자 피폭 선량 평가 (Evaluation of Patient Exposure Dose during Cardiac Electrophysiology Study under Various Conditions)

  • 고성빈;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.501-508
    • /
    • 2023
  • This study used a adult absorption dose phantom (CIRS model 701-G, USA) made of human equivalent material and the vascular imaging equipment Allura Xper FD 20 (Philips, Netherlands). Optically stimulated luminescent dosimeters (OSLD) were inserted into the anatomical positions corresponding to each organ, and the exposure dose was measured. Dose area product (DAP) and air kerma (AK) measured by the dose meter in the equipment were compared. Continuous imaging was performed at two angles for a total of 20 minutes, with a frame per seconds of 3.75 and 7.5 fps and an FOV of 42 cm, 37 cm, and 31 cm, respectively, under the conditions of fluoflavor I, II, and III, each selected for 5 repetitions. This study was found that selecting a lower fps was the most effective way to reduce patient exposure dose, and adjusting the fluoflavor was a good alternative method for reducing patient exposure dose at high fps. Therefore the method of condition change with the greatest dose reduction effect is to set the minimum FPS and can reduce patient exposure dose according to geometric conditions and fluoflavor characteristics.