• Title/Summary/Keyword: Min-Max

Search Result 1,657, Processing Time 0.03 seconds

Evaluation on Compression Wave Velocities and Moduli of Gyeongju Compacted Bentonite (경주 압축 벤토나이트의 압축파속도와 탄성계수 산정 연구)

  • Balagosa, Jebie;Yoon, Seok;Choo, Yun Wook
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.7
    • /
    • pp.41-50
    • /
    • 2019
  • Gyeongju bentonite is a buffer material primarily considered in Korea and it is highly compacted as a part of an engineered barrier system (EBS) of high-level radioactive waste repository. The compacted bentonite undergoes swelling stress by groundwater penetration and thermal stress by decay heat from a canister. Therefore, the mechanical properties of the compacted bentonite buffer material is crucial for the performance assessment of EBS. This paper aims to evaluate deformation properties of Gyeongju compacted bentonite using seismic methods. Two sets of compacted bentonite specimens were prepared having dry densities of $1.59g/cm^3$ and $1.75g/cm^3$ with water contents of 10.6% and 8.7%. Free-free resonant column tests were performed to measure constrained and unconstrained compression wave velocities. With the measured wave velocities, Young's modulus ($E_{max}$) and constrained modulus ($M_{max}$), material damping ratio ($D_{min}$), and Poisson's ratio at small strain were determined. As results, this paper evaluates the deformation properties of Gyeongju compacted bentonite and compares them with the results of previous researches.

Differential Diagnosis of Chemical-induced Hepatobiliary Toxicities Using a New Hepatobiliary Imaging Agent in Mice

  • Ryu, Chong-Kun;Pie, Jae-Eun;Choe, Jae-Gol;Cheon, Joon;Sohn, Jeong-Won;Jurgen Seidel;David S. Paik;Michael V. Green;Chang H. Paik;Kim, Meyoung-Kon
    • Environmental Mutagens and Carcinogens
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • We have synthesized $^{99m}$Tc-mercaptoacetyltriglycine (MAG3)-biocytin as a new imaging agent for hepatobiliary scintigraphy. The aim of this study was to evaluate the usefulness of $^{99m}$Tc-MAG3-biocytin scintigraphy in differentiating carbon tetrachloride ( $CCl_4$)-induced hepatotoxicity from $\alpha$-naphthylisothiocyanate (ANIT)-induced cholestasis in mice, which reflecting the differential diagnosis of neonatal jaundice caused by neonatal hepatitis from congenital biliary atresia in humans. Methods: Balb/c mice (female, 20 g, n=4-6) were pretreated with $CCl_4$(0.5 or $1.0m\ell$/kg) and ANIT ($150 or 300 m\ell$/kg) 18 h before scintigraphy. Biochemical and histopathological examinations showed a pattern of typical acute hepatitis (increase of transaminases and hepatocellular necnsis) in $CCl_4$-treated mice and cholestasis (increase of alkaline phosphatase and ${\gamma}$-glutamyltransferase, and biliary hyperplasia) in ANIT-treated mice, respectively, Mice were fasted at least 4 hr prior to the intravenous injection of $^{99m}$Tc-MAG3-biocytin (18.5 MBq/20$\mu\textrm{g}$) in 2% human serum albumin in saline. Scintigraphy was performed with a ${\gamma}$-camera equipped with a 1-mm diameter pin-hole collimator for 30 min and images were acquired every 15 s. We compared the values of physical parameters, such as peak liver/heart ratio ($${\gamma}$_{max}$) and peak ratio time ($t_{max}$) far $^{99m}$Tc-MAG3-biocytin scintigraphy. Results: Scintigraphic parameters of the $CCl_4$-pretreated (0.5 $m\ell$/kg) group showed a 81.9% decrease of r$_{max}$, and 42.2% decrease of $t_{max}$, whereas the ANIT-pretreated ( $150m\ell$/kg) group showed a 53% decrease of $r_{max}$, and 2.36-fold increase of $t_{max}$, (P<0.05). These results demonstrate that the decrease of $r_{max}$ and the shortening of $t_{max}$ are characteristic features for hepatotoxicity, in contrast to the increase of $t_{max}$ and decrease of $r_{max}$ for biliary hyperplasia. Conclusion: $^{99m}$Tc-MAG3-biocytin hepatobiliary scintigraphy can distinguish hepatitis from cholestasis in mice model and may be similarly useful in humans which differentiating the cause of neonatal jaundice in clinical study.cal study.cal study.cal study.

  • PDF

Impact of concurrent inspiratory muscle and aerobic exercise training on pulmonary function and cardiopulmonary responses (흡기근육 훈련과 유산소운동의 동시적용이 심폐반응과 폐기능에 미치는 영향)

  • Jung, H.J.;Lee, D.T.
    • Exercise Science
    • /
    • v.21 no.3
    • /
    • pp.373-384
    • /
    • 2012
  • The effects of inspiratory muscle training in conjunction with aerobic exercise on inspiratory muscle strength, pulmonary function, and maximal oxygen uptake(VO2max) were examined. Twenty four healthy collegiate men were divided into three groups; respiratory muscle training group(RTG; n=8), running exercise group(REG; n=8), and both respiratory muscle training and running group(BTG; n=8). Their pulmonary function, maximal inspiratory pressures(PImax), and VO2max were assessed before and after intervention. RTG underwent inspiratory muscle training(IMT) with load set to 50 % of PImax, 30 times per session, twice a day, 4 days a week REG ran on a treadmill at 70-75 % of VO2max for 30 min a day, 4 days a week. BTG participated both IMT and the running exercise. Participant's anthropometric parameters and pulmonary function were not changed. VO2max increased by 6.1±3.3 %, 5.9±6.6 %, and 10.0±8.3 % in RTG, REG, and BTG, respectively(p< .05), and PImax also increased by 21.7±14.3 %, 19.7±12.0 %, and 27.0±12.1 % in RTG, REG, and BTG, respectively, but no group differences were found. Based on the study, although statistically insignificant, BTG showed the biggest increase of VO2max and PImax indicating a possible synergic effect of inspiratory muscle training and aerobic exercise on respiratory responses.

A Design of Sign-magnitude based Multi-mode LDPC Decoder for WiMAX (Sign-magnitude 수체계 기반의 WiMAX용 다중모드 LDPC 복호기 설계)

  • Seo, Jin-Ho;Park, Hae-Won;Shin, Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.11
    • /
    • pp.2465-2473
    • /
    • 2011
  • This paper describes a circuit-level optimization of DFU(decoding function unit) for LDPC decoder which is used in wireless communication systems including WiMAX and WLAN. A new design of DFU based on sign-magnitude arithmetic instead of two's complement arithmetic is proposed, resulting in 18% reduction of gate count for 96 DFUs array used in mobile WiMAX LDPC decoder. A multi-mode LDPC decoder for mobile WiMAX standard is designed using the proposed DFU. The LDPC decoder synthesized using a 0.18-${\mu}m$ CMOS cell library with 50 MHz clock has 268,870 gates and 71,424 bits RAM, and it is verified by FPGA implementation.

Design and Fabrication of Quadruple Band Antenna with DGS (DGS를 적용한 4중대역 안테나의 설계 및 제작)

  • Kim, Min-Jae;Choi, Tea-Il;Choi, Young-Kyu;Yoon, Joong-Han
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.31-38
    • /
    • 2020
  • In this paper, we propose a quadruple band antenna for GPS/WLAN/WiMAX application. The proposed antenna has quadruple band characteristics by considering the interconnection of four strip lines and DGS on the ground place. The total substrate size is 20.0 mm (W1) ⨯27.0 mm (L1), thickness (h) 1.0 mm, and the dielectric constant is 4.4, which is made of 20.0 mm (W2)⨯ 27.0 mm (L8 + L6+ L10) antenna size on the FR-4 substrate. From the fabrication and measurement results, bandwidths of 60 MHz (1.525 to 1.585 GHz) bandwidth for GPS band, 825 MHz (3.31 to 4.135 GHz) bandwidth for WiMAX band and 480 MHz (2.395 to 2.975 GHz) and 385 MHz (5.10 to 5.485 GHz) bandwidth for WLAN band were obtained on the basis of -10 dB. Also, gain and radiation pattern characteristics are measured and shown in the frequency of triple band as required.

Bioequivalence of Senital Tablet to Airtal Tablet (Aceclofenac 100 mg) (에어탈 정(아세클로페낙 100 mg)에 대한 세니탈 정의 생물학적 동등성)

  • Kim, Soo-Jin;Oh, In-Joon;Park, Haeng-Soon;Seo, Se-Min;Suh, Soon-Pal;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.28 no.4
    • /
    • pp.289-294
    • /
    • 1998
  • Bioequivalence of two aceclofenac tablets, the $Airtal^{TM}$ (Daewoong Pharmaceutical Co., Ltd.) and the $Senital^{TM}$ (Hana Pharmaceutical Co., Ltd.), was evaluated according to the guideline of KFDA. Fourteen normal male volunteers (age $20{\sim}29$ years old) were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one tablet containing 100 mg of aceclofenac was orally administered, blood was taken at predetermined time intervals and the concentration of aceclofenac in plasma was determined with an HPLC method using UV detector. The pharmacokinetic parameters ($C_{max}$, $T_{max}$ and $AUC_t$) were calculated and ANOVA was utilized for the statistical analysis of parameters. The results showed that the differences in $C_{max}$, $T_{max}$ and $AUC_t$ between two tablets were 3.69%, 2.44% and 0.51%, respectively. The powers $(1-{\beta})$ for $C_{max}$, $T_{max}$ and $AUC_t$ were 87.85%, 98.70% and more than 99%, respectively. Detectable differences $({\Delta})$ and confidence intervals were all less than ${\pm}20%$. All of these parameters met the criteria of KFDA for bioequivalence, indicating that $Senital^{TM}$ tablet is bioequivalent to $Airtal^{TM}$ tablet.

  • PDF

Effects of Thiuram, Thiazole, and Sulfenamide Accelerators on Silica Filled Natural Rubber Compound upon Vulcanization and Mechanical Properties (Thiuram, Thiazole, Sulfenamide계 가황촉진제가 실리카로 충진된 천연고무 복합소재의 가황 및 물성에 미치는 영향)

  • Choi, Changyong;Kim, Seong-Min;Park, Young-Hoon;Jang, Mi-Kyeong;Nah, Jae-Woon;Kim, Kwang-Jea
    • Applied Chemistry for Engineering
    • /
    • v.22 no.4
    • /
    • pp.411-415
    • /
    • 2011
  • Various types of accelerators, thiuram (TMTD, DPTT), thiazole (MBT, MBTS), and sulfenamide (CBS, NOBS) are added into a silica filled natural rubber compound. Their effects on vulcanization and mechanical properties are investigated. TMTD showed the fastest vulcanization rate, the higer maximum torque ($T_{max}$), and the excellent mechanical properties (300% modulus, tensile strength, elongation). MBT and MBTS showed an intermediate vulcanization rate between thiuram and sulfenamide type and added ones, and also showed the lower $T_{max}$ and mechanical properties compared to that of other compounds. Finally, NOBS showed the slowest vulcanization rate and the lower mechanical property but the moderate $T_{max}$.

Evaluate Utility of Thyroid Cancer Discrimination by 18F-FDG PET/CT Delay Scan Images (18F-FDG PET/CT검사에서 지연영상을 이용한 갑상선암 진단의 유용성 평가)

  • Lee, Hyeon-Guck;Han, Man-Seok;Kim, Yong-Kyun;Seo, Sun-Youl;Jeon, Min-Cheol;Kim, Tae-Hyung;Hong, Seong-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2958-2965
    • /
    • 2013
  • Purpose : To evaluate the degree of malignancy of incident thyroid lesion found in 18F-FDG PET/CT findings and the usefulness of the method suggested in this study, we applicate the Delay Scan Method that differentiate a false positive benign tumor, inflammation and malignancy, as well as make the criteria of SUV. Materials and Methods : A retrograde study was conducted of 25 patients(1 exception) who were admitted in E hospital to receive 18F-FDG PET/CT examination until Janaary and April of 2008. 18F-FDG PET/CT image photographing was taken in Biograph-Duo made by SIEMENS, after taking normal 18F-FDG PET/CT image(1hr) and then 1hr later we took the thyroid 1 bed-delayed image for the patients who showed abnormal thyroid 18F-FDG uptake and above 2.0 SUV for 2 minutes every 1 bed. For the patients who showed abnormal thyroid uptake and above 2.0 SUV, 1hr later, we took a 1 bed-delayed image and then made a comparative study between measured maxSUV of 1hr-abnormal uptake image and that of 2hr-delayed image. Results : In this 18F-FDG PET/CT study among the patients who showed incidental 18F-FDG thyroidal uptake the number of thyroid cancer was 5(20.8%), all of then showed benign findings. a comparison of results for 18F-FDG PET/CT. the benign patient measured maxSUV in the PET/CT. image(1hr) mean value 5.06maxSUV and delay image(2hr) mean value 5.23maxSUV differences of two value is 0.19maxSUV and the malignantIt patient measured maxSUV in the PET/CT. image(1hr) mean value 9.63maxSUV and delay image(2hr) mean value 10.65maxSUV differences of two value is 10.65maxSUV in Thyroid abnormal uptake patients. Conclusion : in the case of incidental 18F-FDG uptake in thyroid, max SUV of focal thyroid lesion is above 5.0 if 18F-FDG PET/CT examine the delayed images to add, You could see that reasonable diagnostic method useful. to differentiate whether lesions of malignant.

HPLC Method for the Determination of Nicorandil in Human Plasma

  • Park, Sun-Hee;Shin, In-Chul
    • Biomolecules & Therapeutics
    • /
    • v.16 no.2
    • /
    • pp.168-172
    • /
    • 2008
  • The present study is to determine of sensitive nicorandil analysis method using HPLC and measure the pharmacokinetics parameters (bioavailability, $C_{max}$, $T_{max}$, Ke, $T_{1/2}$) of nicorandil (5 mg, Tab; Choongwae Pharma Corporation). Plasma (500 ul) was mixed with furosemide (internal standard, 500 ug/ml). Detection wavelength was 256 nm. The mixture of 0.01 M ammonium acetate and acetonitrile 80:20 (v/v) was used mobile phase. The HPLC separation was accomplished on ODC reverse HPLC column. The nicorandil was analyzed by a HPLC system, which consists of CAPCELL PAK C18 column (5 ${\mu}$m, 4.6 × 150 mm) and a chromatography data analysis S/W, using a isocratic mobile phase (mixture of 0.01 M ammonium acetate and acetonitrile 80:20 ) at 1.0 ml/min. Its sensitivity, selectivity, accuracy and precision must be adequate for the bioavailabilty study of nicorandil, and the linearity ($r^2$ ≥ 0.9994) of nicorandil was also proved in the range of 0.05 ug/ml . 3 ug/ml. The pharmacokinetic parameters of nicorandil (5 mg) tablets were measured as the follow. AUC: 0.19 ug/ml·hr, $C_{max}$: 0.14 ug/ml, $t_{max}$: 0.58 hr, Ke: 0.11 hr., $t_{1/2\beta}$: 6.76 hrs. This method is simple and sensitive HPLC method using UV detector for determination of nicorandil in human plasma.

SRR and CSRR Loaded UWB Antenna with Tri-Band Notch Capability (SRR과 CSRR을 이용한 삼중 대역 차단 초광대역 안테나)

  • Yoo, Min-Yeong;Lim, Sung-Joon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.320-327
    • /
    • 2012
  • In this paper, a novel ultra wide band(UWB) antenna with tri-band notch capability is proposed. The proposed antenna can reject WiMAX(3.3~3.7 GHz), WLAN IEEE 802.11a/n(5.15~5.825 GHz), and ITU(8.025~8.4 GHz) bands. Band rejection capability is achieved only split ring resonators(SRRs) and complementary SRRs(CSRRs). The SRR under the radiating patch, the CSRR loaded on the radiating patch, and the CSRRs on the ground of the CPW feeding reject the WiMAX, WLAN, and ITU bands, respectively. The simulation and measurement results demonstrate the performances of the proposed antenna.