• Title/Summary/Keyword: Midsagittal Plane

Search Result 39, Processing Time 0.026 seconds

Quantitative evaluation of palatal bone thickness in patients with normal and open vertical skeletal configurations using cone-beam computed tomography

  • Suteerapongpun, Piyoros;Wattanachai, Tanapan;Janhom, Apirum;Tripuwabhrut, Polbhat;Jotikasthira, Dhirawat
    • Imaging Science in Dentistry
    • /
    • v.48 no.1
    • /
    • pp.51-57
    • /
    • 2018
  • Purpose: To perform a comparative analysis of the palatal bone thickness in Thai patients exhibiting class I malocclusion according to whether they exhibited a normal or open vertical skeletal configuration using cone-beam computed tomography (CBCT). Materials and Methods: Thirty CBCT images of Thai orthodontic patients (15-30 years of age) exhibiting class I malocclusion with a normal or open vertical skeletal configuration were selected. Palatal bone thickness was measured in a 3.0-mm grid pattern on both the right and left sides. The palatal bone thickness of the normal-bite and open-bite groups was compared using the independent t-test. The level of significance was established at P<.05. Results: The palatal bone thickness in the normal-bite group ranged from $2.2{\pm}1.0mm$ to $12.6{\pm}4.1mm$. The palatal bone thickness in the open-bite group ranged from $1.9{\pm}1.1mm$ to $13.2{\pm}2.3mm$. The palatal bone thickness was lower at almost all sites in patients with open bite than in those with normal bite. Significant differences were found at almost all anteroposterior sites along the 3 most medial sections (3.0, 6.0, and 9.0 mm lateral to the midsagittal plane)(P<.05). Conclusion: Class I malocclusion with open vertical skeletal configuration may affect palatal bone thickness, so the placement of temporary anchorage devices or miniscrew implants in the palatal area in such patients should be performed with caution.

Schematic of mean thickness distribution on the lateral aspect of the canine frontal sinus as an experimental model of sinus surgery

  • Bae, Jung-Hee;Kim, Han-Seok;Won, Sung-Yoon;Kim, Da-Hye;Jung, Ui-Won;Kim, Hee-Jin;Hu, Kyung-Seok
    • Anatomy and Cell Biology
    • /
    • v.51 no.4
    • /
    • pp.236-242
    • /
    • 2018
  • The dog frontal sinus may represent an alternative model dental implant research; its topographical resemblance to the maxillary sinus renders it a potentially favorable experimental environment. The aim of this study was thus to elucidate the anatomical configuration of the canine frontal sinus and histological characteristics, and to determine whether it could be a new canine experimental model for dental implant research. Twenty-four sides of canine frontal bones were harvested. The distance from the nasion to the emerging point of the lateral aspect of the canine frontal sinus was measured with the aid of Lucion software. The thicknesses of the canine frontal sinus wall were measured, and the two specimens stained with hematoxylin and eosin. The mean distance from the nasion to the emerging point of the lateral aspect of the canine frontal sinus was 16.0 mm. The mean thicknesses of the canine frontal bone at 3, 6, 9, 12, and 15 mm lateral to the midsagittal plane were 2.3, 2.7, 3.2, 3.8, and 3.7 mm, respectively. The canine frontal sinus was lined with pseudostratified ciliated columnar epithelium. These data suggest that the canine frontal sinus is a suitable alternative to the canine maxillary sinus as a model for studying various sinus augmentation protocols.

Dose Distribution of Co-60 Photon Beam in Total Body Irradiation (Co-60에 의한 전신조사시 선량분포)

  • Kang, Wee-Saing
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.109-120
    • /
    • 1991
  • Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.

  • PDF

Anatomical characteristics of the midpalatal suture area for miniscrew implantation using CT image (정중구개봉합부의 해부학적 구조에 관한 전산화 단층촬영을 이용한 연구)

  • Park, Young-Chel;Lee, Jong-Suk;Kim, Doo-Hyung
    • The korean journal of orthodontics
    • /
    • v.35 no.1 s.108
    • /
    • pp.35-42
    • /
    • 2005
  • There is lack of data for the amount of vertical bone in the midpalatal region for miniscrew implantation. The purpose of this study was to measure the structure of the midpalatal suture area using CT image and V-works 4.0 program (Cybermed Inc, Seoul, Korea). CT images of 14 male and 14 female adults were reconstructed. In detail, it was 1) to measure the length of maxilla on the midsagittal plane 2) to measure vertical bone height in the midpalatal area 3) to establish the zone of safety for miniscrew implantation. The following results were obtained. The mean length of ANS-PNS was 51.08mm in males and 47.34mm in females. There was a statistically significant difference between males and females (p<0.05). The vertical bone height of the midpalatal suture area was above 0mm except for 6mm posterior from the central Point of ANS-PNS in males The zone of safety was located 19.43mm posterior from the ANS in males while it was 17.62mm in females along the palatal plane. These results support that the safety zone of the midpalatal area is suitable for screw implantation. Midpalatal miniscrew implantation is a powerful tool in modern orthodontics Through many applications. it can expand the modern orthodontic field.

Characteristics of Achilles Tendon Insertion on Posterior Aspect of the Calcaneus without Pathological Deformity in Adults: A Magnetic Resonance Imaging Study (성인에서의 병적 위치 변형이 없는 아킬레스건 종골 후방 부착부의 특징: 자기공명영상 계측 연구)

  • Gwak, Heuichul;Jung, Daewon;Park, Hyungtaek;Ha, Dongjun;Kwak, Jaeyong;Kim, Uicheol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.3
    • /
    • pp.112-115
    • /
    • 2016
  • Purpose: We aimed to investigate the safety zone for Achilles tendon insertion in the posterior aspect of the calcaneus via the use of magnetic resonance imaging (MRI) when planning for insertional Achilles tendinopathy. Materials and Methods: This study included 95 patients. The MRI of midsagittal plane of the ankle joint was used to measure the proximal and distal insertion point for the Achilles tendon in the posterior aspect of the calcaneus. Patients were divided into three groups according to the proportion of the distal insertion point out of the entire calcaneal length: the proximal, middle, and distal insertion groups. Results: The mean proximal and distal insertion points for the Achilles tendon were measured as 1.05 cm (0~2.11 cm) and 2.36 cm (1.60~2.93 cm), respectively. When the posterior aspect of the calcaneus was used as the reference plane, none of the patients was in the proximal insertion group, while 75 and 20 patients were in the middle and distal insertion groups, respectively. The insertion portion was longer in the distal insertion group ($1.47{\pm}0.25cm$) than in the middle insertion group ($1.27{\pm}0.35cm$). Statistically significant differences with respect to the length of the insertion portion were observed between the two groups (p=0.008). Conclusion: Removal of more than 1 cm below the superior margin of the posterior calcaneus may be dangerous. An MRI study on the Achilles tendon of patients without hindfoot deformity or tendinopathy revealed various insertional characteristics. Preoperative MRI evaluation is safer than relying solely on the simple radiological assessment when planning for insertional Achilles tendinopathy.

EFFECTS ON THE ENLARGEMENT RATIOS DUE TO CHANGES OF HEAD POSTURE ON LATERAL HEADFILMS (측두 규격방사선사진 촬영시 두부의 위치변화가 확대율에 미치는 영향)

  • Seo, Young-Hun;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.185-194
    • /
    • 2001
  • This study was designed to evaluate the effects of angulation changes of head posture on the enlargement ratios of a lateral headfilm depending on the vortical or horizontal rotation of the objects. A device was constructed to measure regional changes of enlargement ratios. The device was held within the cephalostat and cephalograms recorded at each measured degrees of the device tilting, vertically and horizontally. The enlargement ratios of the horizontal, vertical, and angular measurements on the films taken at each tilted angulations were obtained and compared with those on the films taken without rotation. In summary, the enlargement ratios of the horizontal linear measurements were decreased during horizontal rotations. The enlargement ratios of vortical measurements of the right side on the film were increased and those of the left side were decreased by the horizontal rotations. Enlargement ratios of horizontal measurements were affected further than those of vertical measurements by the same angular changes of the horizontal rotations. Therefore, a disruption of parallelism between the object's midsagittal plane and the film could result in distortion of the image while vertical rotation around the object's porionic axis would not significantly affect the enlargement ratios on the headfilm.

  • PDF

A comparative study of the deviation of the menton on posteroanterior cephalograms and three-dimensional computed tomography

  • Lee, Hee Jin;Lee, Sungeun;Lee, Eun Joo;Song, In Ja;Kang, Byung-Cheol;Lee, Jae-Seo;Lim, Hoi-Jeong;Yoon, Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.33-38
    • /
    • 2016
  • Purpose: Facial asymmetry has been measured by the severity of deviation of the menton (Me) on posteroanterior (PA) cephalograms and three-dimensional (3D) computed tomography (CT). This study aimed to compare PA cephalograms and 3D CT regarding the severity of Me deviation and the direction of the Me. Materials and Methods: PA cephalograms and 3D CT images of 35 patients who underwent orthognathic surgery (19 males and 16 females, with an average age of $22.1{\pm}3.3years$) were retrospectively reviewed in this study. By measuring the distance and direction of the Me from the midfacial reference line and the midsagittal plane in the cephalograms and 3D CT, respectively, the x-coordinates ($x_1$ and $x_2$) of the Me were obtained in each image. The difference between the x-coordinates was calculated and statistical analysis was performed to compare the severity of Me deviation and the direction of the Me in the two imaging modalities. Results: A statistically significant difference in the severity of Me deviation was found between the two imaging modalities (${\Delta}x=2.45{\pm}2.03mm$, p<0.05) using the one-sample t-test. Statistically significant agreement was observed in the presence of deviation (k=0.64, p<0.05) and in the severity of Me deviation (k=0.27, p<0.05). A difference in the direction of the Me was detected in three patients (8.6%). The severity of the Me deviation was found to vary according to the imaging modality in 16 patients (45.7%). Conclusion: The measurement of Me deviation may be different between PA cephalograms and 3D CT in some patients.

Laryngeal height and voice characteristics in children with autism spectrum disorders (자폐스펙트럼장애 아동의 후두 높이 및 음성 특성)

  • Lee, Jung-Hun;Kim, Go-Woon;Kim, Seong-Tae
    • Phonetics and Speech Sciences
    • /
    • v.13 no.2
    • /
    • pp.91-101
    • /
    • 2021
  • The purpose of this study was to investigate laryngeal characteristics in children with autism spectrum disorders (ASD). A total of 50 children participated, including eight children aged 2 to 4 years old diagnosed with ASD and 42 normal controls at the same age. All children recorded X-ray images of the midsagittal plane of the cervical spine and larynx, and compared the laryngeal positions of ASD and control. In addition, samples of children with vowel prolongation were collected and analyzed for acoustic parameters. X-rays showed that the height of the hyoid bone in the normal group was the lowest at 3 years of age, and ascended at 4 years of age. Nevertheless, the distance from the external acoustic meatus to the hyoid bone was longest at age 4. 4-year-olds with explosive language development showed laryngeal height elevation and anteriorization. In contrast, the hyoid height of the ASD group of all ages was lower than that of the control group, and there was no difference in the hyoid position between the ages. As a result of acoustic evaluation, PFR, vFo, and vAm were significantly higher ASD than control. Low laryngeal height of ASD children may be associated with delayed language development. PFR, vFo, and vAm seem to be voice markers showing the difference between normal and ASD children.

A study on the smile of Korean Youth compared with twenty years ago (20년전과 비교한 한국청년의 미소 변화에 관한 연구)

  • Beom, Seung-Gyun;Jung, Ji-Hye;Kim, Tae-Young;Lee, Kyung-Eun;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.162-168
    • /
    • 2012
  • Purpose: Teeth are generally exposed when people smiling. Moreover, the exposed teeth and soft tissue when smiling becomes an important guideline for esthetically prosthetic restoration. This research is to compare and find out differences of Korean young men's smile living in presence and twenty years ago. Materials and methods: Subjects, 100 young men (50 male and 50 female), were required about several aspects; normally developed physical condition, no psychological or genetic disorders, a fine face with no loss of teeth, no experience in orthodontic or prosthetic treatment, relatively normal occlusion, aged between 20-29. The photos of the subject at rest position and front face when fully smiled were taken three times. 100 photos (50 male and 50 female) were chosen at random from the 240 university students' smile photos taken by Yoon and his colleagues in 1991. By Hulsey's method of measuring smile, several factors; the change of upper lip curvature, the change of the relation between the upper lip and teeth, parallelism between Mx. incisor and lower lip, contact relation between Mx. incisor and lower lip and teeth displayed in a smile, were measured and analyzed. Meanwhile, ten dentists assessed aesthetic evaluation about men and women's smile for twice and recorded and compared smile score. The -test (P<.05) was used to compare the measured value. The difference of smile score was analyzed by t-test (P<.05). Results: The smile score calculated in 2011 (60.22) was higher than that of 1991 (52.80). Among five measurement categories, the noticeable difference was distinguished from two factors; the change of upper lip curvature and contact relation between Mx. incisor and lower lip. Conclusion: The Korean young men's smile has been considerably improved for twenty years. And it is found that the change of upper lip curvature plays an important role, that is, the smile formed with an ascended labial commissure has been increased significantly.