• 제목/요약/키워드: Microwave range method

검색결과 121건 처리시간 0.026초

가정용 전자렌지의 마이크로파 처리가 식품의 보존성에 미치는 영향 (Effects of Microwave Treatment on the Preservation of Foods)

  • 우임선;고용덕
    • 한국식품저장유통학회지
    • /
    • 제4권1호
    • /
    • pp.17-25
    • /
    • 1997
  • The effects of microwave treatment on the perservation of foods, such as a seaweed soup and sea stoned radish shreds, were studied. Microwave treatment of microbial cell suspensions revealed that viable cells decreased dramatically when heated to 6$0^{\circ}C$. However, it was unlikely that microwave treatment to 60 is enough to decrease the viable cell counts efficiently in a seaweed soup and radish shreds. It was thought that microwave heating to at least 7$0^{\circ}C$ as a final temperature was an important factor to reduce microbial cell counts in foods. When foods were heated to 7$0^{\circ}C$ with a repetitive 15 sec "on" followed by 30 sec "off", no big differences were observed in viable counts during storage at 2$0^{\circ}C$ for 3 days, as compared to those treated with a full power. The microwave treatment with three stages was designed to solve problems associated with variations depending on food volumes and difficulties of heat diffusion in a solid food to be irradiated with a microwave oven. The three stage method was found to have a similar efficiency in the reduction of viable cell counts in foods to microwave treatment at a full power and to conventional methods, such as water bath heating or boiling for 3 min with a gas range.in with a gas range.

  • PDF

마이크로웨이브 열분해를 이용한 폴리스티렌으로부터의 고분자 원료 물질의 회수에 관한 연구 (Study on the Recovery of Polymeric Raw-materials from Waste Polystyrene by the Microwave Thermal Decomposition)

  • 강태원;유효운;황택성
    • 한국자원리싸이클링학회:학술대회논문집
    • /
    • 한국자원리싸이클링학회 2003년도 추계정기총회 및 국제심포지엄
    • /
    • pp.190-195
    • /
    • 2003
  • A novel microwave-induced pyrolysis of polystyrene in motor oil was performed using a quartz tube reactor with silicon carbide as the microwave absorbent. Different pyrolysis conditions were investigated, such as time range from 30 minutes to 1 hour and power range from 180 to 250 watt. The distillate components were analyzed with GC-MS, and styrene, 1-methyl styrene, toluene, ethyl benzene were the four main products. Among these, styrene took over 70 percentages. Temperature of the complete pyrolysis using microwave was much lower than that of conventional thermal pyrolysis method.

  • PDF

강유전체를 이용한 이동통신주파수 대역용 박형 전파흡수체의 제조 및 특성 (Fabrication and Properties of Thin Microwave Absorbers of Ferroelectric Materials Used in Mobile Telecommunication Frequency Bands)

  • 이영종;윤여춘;김성수
    • 한국재료학회지
    • /
    • 제12권2호
    • /
    • pp.160-165
    • /
    • 2002
  • High-frequency dielectric and microwave absorbing properties have been investigated in ferroelectric materials (BaTiO$_3$(BT), (1-x)Pb$Mg_{\frac{1}{3}}Nb_{\frac{2}{3}}$)O$_3$-xPbTiO$_3$(PMN-PT), (1-x)Pb$Mg_{\frac{1}{3}}Nb_{\frac{2}{3}}$O$_3$-xPb(Zn_{\frac{1}{3}}Nb_{\frac{2}{3}}$)O$_3$(PMN-PZN) for the aim of thin microwave absorbers in the frequency range of mobile telecommunication. The specimenns are prepared by conventional ceramic processing and complex permittivity has been measured by transmission/reflection method. The ferroelectric materials show high dielectric constant and dielectric loss in the microwave range and their domiant loss mechanism is considered to be domain wall relaxation. The microwave absorbance of BT 0.9PMN-0.1PT, and 0.8PMN-0.2PZN specimen (determined at 2) are found to be 99.5% (at a thickness of 4.5 mm), 50% (2.5 mm), and 30% (2.5 mm), respectively. It is suggested that PMN-PT or PMN-PZN ferroelectrics are good candidate materials for the spacer of λ/4 absorber. The use of ferroelectric materials is effective in reducing the thickness of absorber with their advantage of high dielectric constant.

Electron Spin Resonance (ESR) and Microwave Absorption Studies of Superparamagnetic Iron Oxide Nanoparticles (SPIONs) for Hyperthermia Applications

  • Choi, Yong-Ho;Yi, Terry;Kim, Do-Kyung
    • 한국세라믹학회지
    • /
    • 제48권6호
    • /
    • pp.577-583
    • /
    • 2011
  • Stabilized biocompatible superparamagnetic iron oxide nanoparticles (SPIONs) were prepared by controlled coprecipitation method for hyperthermia application. ESR measurements determined that all of the interactions in the individual SPIONs (1 nm and 11 nm) were antiferromagnetic in nature because the ions contributed to the magnetization with a range of magnetic moments. In-situ monitoring of the temperature increment was performed, showing that the microwave absorption rate of the SPIONs was dispersed in an appropriate host media (polar or non-polar solvents) during microwave irradiation. Microwave absorption energy rates and heat loss of SPIONs in solvent were calculated by non-linear data fitting with an energy balance equation. The microwave absorption rates of SPIONs dispersed in solvent linearly increases when the concentration of SPIONs increases, implying that the microwave absorption rate can be tunable by changing the concentration of SPIONs.

마이크로파 광대역 정위상기 (Microwave Wideband Constant Phase Shifter)

  • Bae, Jung-Yi
    • 대한전자공학회논문지
    • /
    • 제23권2호
    • /
    • pp.182-188
    • /
    • 1986
  • A method of wideband constant phase control is proposed. This can be applied to reflection type phase shifter with p-i-n diode. Using the proposed method, a microwave phase network which consists of a transmission line and reactive circuit element is suggested. By determining theproper values of design parameters, the desired wideband constant phase with different specification can easily be designed. Also, using the proposed method, the parameters variation, and 1.1 dB of insertion loss in the range of 12% bandwidth.

  • PDF

마이크로파 가열을 이용한 Ni-Zn 페라이트의 소결 (Sintering of Ni-Zn Ferrites by Microwave Hybrid Heating)

  • 김진웅;최승철;이재춘;오재희
    • 한국세라믹학회지
    • /
    • 제39권7호
    • /
    • pp.669-674
    • /
    • 2002
  • 마이크로파(2.45GHz, 700w) 에너지를 이용한 마이크로웨이브 하이브리드 소결법으로 90$0^{\circ}C$~107$0^{\circ}C$의 온도 범위에서 Bi$_2$O$_3$와 CuO가 함유된 Ni-Zn 페라이트를 소결하고 이 결과를 일반 소결법으로 소결된 시편과 비교하였다. 각 소결체의 공정 시간은 20~$25^{\circ}C$/min의 승온속도에서 60분 이내에 마칠 수 있었다. XRD분석결과 Ni-Zn페라이트의 단일상만이 관찰되었으며 일반 소결보다 빠른 시간에 소결이 진행되었다. 97$0^{\circ}C$에서 15분 소결 했을 때 소결밀도는 98%로 최대값을 나타내었으며, 모든 소결체의 소결밀도는 90% 이상의 소결 밀도를 나타내었다. 마이크로 하이브리드 소결법으로 소결된 시편과 일반 소결법으로 소결된 시편을 비교하면 소결 특성은 비슷한 결과를 얻을 수 있었다. 마이크로파 에너지를 이용한 소결법은 일반 소결법에 비하여 짧은 시간 안에 공정을 완료할 수 있으므로 공정 시간과 에너지 절약 측면에서 유효한 공정으로 판단된다.

일정 이득 이미턴스 궤적을 이용한 초광대역 마이크로파 증폭기 설계 (Design of Ultra-broadband Microwave Amplifier Using Immittance Loci of Constant Gain)

  • 구경헌;이충웅
    • 대한전자공학회논문지
    • /
    • 제27권9호
    • /
    • pp.1344-1350
    • /
    • 1990
  • A design method of ultra-broadband microwave amplifier is presented. A lossy network is represented as the combination of a serial impedance component and a parallel admittance component, and the realizable ranges of the gain and the reflection coefficients are derived with the components connected to the input, output or interstage network. The matching network has been designed by using the serial and parallel immittance loci which have the constant gain or reflection coefficients within the realizable ranges. Using the proposed method, deisgn examples of ultra-broadband amplifiers operating from dc to 12GHz frequency range are presented.

  • PDF

하이브리드 마이코로파 광대역 증폭기용 임피던스 정합회로 설계 (Design of broad-band impedance matching networks for hybrid microwave amplifier applications)

  • 김남태
    • 전자공학회논문지D
    • /
    • 제35D권5호
    • /
    • pp.11-17
    • /
    • 1998
  • In this paper, the synthesis procedufe of impedance matching network is presented for broad-band microwave amplifier design, whereby amplifier operating in the octave bandwidth is designed and fabricated in detail. The transfer function of the matching netowrks is synthesized by chebyshev approximation and element values for the networks of specified topology are calculatd for various MILs and ripples. After the transistor is modeled by negative-image device model, the synthesis procedure for matching networks is applied to broad-band amplifier design which has electrical performance of about 12dB gain in 4 to 8GHz range. Experimental results obtained from the fabricated amplifier are shown to approach the electrical performance designed in the given frequency range. Construction of the impedance matching networks by transfer function synthesis is very useful method for the design of broad-band microwave amplifiers.

  • PDF

$Ba(Mg_{1/3}Nb_{2/3})O_3$ 세라믹스의 양이온 규칙구조와 유전특성: I. 장거리 규칙도 (Cation Ordering and Microwave Dielectric Properties of $Ba(Mg_{1/3}Nb_{2/3})O_3$Ceramics: I. Long-Range Order Parameter)

  • 김영웅;박재환;김윤호;박재관
    • 한국결정학회지
    • /
    • 제12권2호
    • /
    • pp.76-80
    • /
    • 2001
  • Ba(Mg/sub 1/3/Nb/sub 2/3/)O₃분말을 columbite precursor 법으로 합성하고 열처리 조건을 달리하여 소결 한 다음 1 : 2 양이온 배열의 장거리 규칙도의 변화를 조사하였다. 1350℃ 소결 시편에서는 소결 시간의 증가에 의해 장거리 규칙도가 감소하였으며 1500℃-4h의 조건에서 열처리한 시편의 경우는 0.94정도의 높은 규칙도를 가졌다.

  • PDF

Development of Continuous Flow Microwave Digestion Procedures for Analysis of Trace Metal in Water Using Ion Chromatography

  • Youn Doo Kim;Gae Ho Lee;Hyung Seung Kim;Dong Soo Kim;Kwang Kyu Park
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권9호
    • /
    • pp.786-791
    • /
    • 1994
  • A simple and rapid sample pretreatment process necessary for determination of metal oxides in water was proposed. Samples were injected into the continuous-flow tube installed inside the microwave oven and the treated samples were cooled before entered to the Ion Chromatography (IC) or Inductively Coupled Plasma (ICP). By coupling this microwave digestion system with IC or ICP, a fully automatic analytical procedures may be easily established. In this study, two different types of digestion methods were considered; the open tubing method (OTM) and the restraint tubing method (RTM). The RTM was proved to be 3 times faster in digestion period and 10 times higher in detection range than the OTM. Validation of proposed sample digestion system was carried out by using an ICP. The results showed that both of continuous-flow methods, the OTM and the RTM were comparable in accuracies with the conventional batch-type vessel digestion method.