• Title/Summary/Keyword: Microimplant

Search Result 26, Processing Time 0.026 seconds

Nonextraction treatment of Class II division 2 in an adult patient using microimplant anchorage (MIA) (Microimplant Anchorage(MIA)를 이용한 II급 2류 성인 환자의 비발치 치험례)

  • Chae, Jong-Moon
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.485-494
    • /
    • 2005
  • Maxillary anterior teeth were intruded and lingually root torqued with two maxillary anterior microimplants between the lateral incisors and canines. Overerupted maxillary canines were intruded with two other microimplants between the maxillary canines and first premolars. Maxillary posterior teeth and canines were distalized, then the maxillary incisors were retracted with two maxillary posterior microimplants between the first and second molars. The mandibular anterior teeth were intruded and the mandibular posterior teeth were extruded with conventional method such as anterior bite plane, intrusion arch and Class II elastics. The mandible moved slightly forward after the correction of deep bite and retroclination of the upper incisors. Consequently, microimplant anchorage (MIA) provided absolute anchorage for simultaneous correction of Class II canine and molar relationships and deep overbite.

Finite element analysis of cortical bone strain induced by self-drilling placement of orthodontic microimplant (Self-drilling 방식의 마이크로임플란트 식립에 의해 발생하는 피질골 스트레인의 유한요소해석)

  • Park, Jin-Seo;Yu, Won-Jae;Kyung, Hee-Moon;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.203-212
    • /
    • 2009
  • Objective: The aim of this study was to evaluate the strain induced in the cortical bone surrounding an orthodontic microimplant during insertion in a self-drilling manner. Methods: A 3D finite element method was used to simulate the insertion of a microimplant (AbsoAnchor SH1312-7, Dentos Co., Daegu, Korea) into 1 mm thick cortical bone. The shape and dimension of thread groove in the center of the cortical bone produced by the cutting flute at the apical of the microimplant was obtained from animal test using rabbit tibias. A total of 3,600 analysis steps was used to calculate the 10 turns and 5 mm advancement of the microimplant. A series of remesh in the cortical bone was allowed to accommodate the change in the geometry accompanied by the implant insertion. Results: Bone strains of well higher than 4,000 microstrain, the reported upper limit for normal bone remodeling, were observed in the peri-implant bone along the whole length of the microimplant. Level of strains in the vicinity of either the screw tip or the valley part were similar. Conclusions: Bone strains from a microimplant insertion in a self-drilling manner might have a negative impact on the physiological remodeling of cortical bone.

Cortical bone strain during the placement of orthodontic microimplant studied by 3D finite element analysis (3차원 유한요소법을 이용한 교정용 마이크로임플란트 식립 시의 피질골 스트레인 해석)

  • Nam, Ok-Hyun;Yu, Won-Jae;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.228-239
    • /
    • 2008
  • Objective: The aim of this study was to evaluate the strain induced in the cortical bone surrounding an orthodontic microimplant during insertion. Methods: A 3D finite element method was used to model the insertion of a microimplant (AbsoAnchor SH1312-7, Dentos Co., Daegu, Korea) Into 1 mm thick cortical bone with a pre-drilled hole of 0.9 mm in diameter. A total of 1,800 analysis steps was used to simulate the 10 turns and 5 mm advancement of the microimplant. A series of remesh in the cortical bone was allowed to accommodate the change in the geometry accompanied by the implant insertion. Results: Bone strains of well higher than 4,000 microstrain, the reported upper limit for normal bone remodeling, was observed in the bone along the whole length of the microimplant. At the bone in the vicinity of the screw tip, strains of higher than 100% was recorded. The insertion torque was calculated at approximately 1.2 Ncm which was slightly lower than those measured from the animal experiment using rabbit tibias. Conclusions: The insertion process of a microimplant was successfully simulated using the 3D finite element method which showed that bone strains from a microimplant insertion might have a negative impact on physiological remodeling of bone.

Finite element analysis of peri-implant bone stresses induced by root contact of orthodontic microimplant (치근접촉이 마이크로 임플란트 인접골 응력에 미치는 영향에 대한 유한요소해석)

  • Yu, Won-Jae;Kim, Mi-Ryoung;Park, Hyo-Sang;Kyung, Hee-Moon;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.41 no.1
    • /
    • pp.6-15
    • /
    • 2011
  • Objective: The aim of this study was to evaluate the biomechanical aspects of peri-implant bone upon root contact of orthodontic microimplant. Methods: Axisymmetric finite element modeling scheme was used to analyze the compressive strength of the orthodontic microimplant (Absoanchor SH1312-7, Dentos Inc., Daegu, Korea) placed into inter-radicular bone covered by 1 mm thick cortical bone, with its apical tip contacting adjacent root surface. A stepwise analysis technique was adopted to simulate the response of peri-implant bone. Areas of the bone that were subject to higher stresses than the maximum compressive strength (in case of cancellous bone) or threshold stress of 54.8MPa, which was assumed to impair the physiological remodeling of cortical bone, were removed from the FE mesh in a stepwise manner. For comparison, a control model was analyzed which simulated normal orthodontic force of 5 N at the head of the microimplant. Results: Stresses in cancellous bone were high enough to cause mechanical failure across its entire thickness. Stresses in cortical bone were more likely to cause resorptive bone remodeling than mechanical failure. The overloaded zone, initially located at the lower part of cortical plate, proliferated upward in a positive feedback mode, unaffected by stress redistribution, until the whole thickness was engaged. Conclusions: Stresses induced around a microimplant by root contact may lead to a irreversible loss of microimplant stability.

Influence of late removal after treatment on the removal torque of microimplants

  • Kim, Ho-Jin;Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.52 no.3
    • /
    • pp.201-209
    • /
    • 2022
  • Objective: To compare the removal torque of microimplants upon post-use removal and post-retention removal and to assess the influencing factors. Methods: The sample group included 241 patients (age, 30.25 ± 12.2 years) with 568 microimplants. They were divided into the post-use (microimplants removed immediately after use or treatment) and post-retention (microimplants removed during the retention period) removal groups. The removal torque in both groups was assessed according to sex, age, placement site and method, and microimplant size. Pearson correlation and multiple linear regression analyses were performed for evaluating variables influencing the removal torque. Results: The mean period of total in-bone stay of microimplants in the post-retention removal group (1,237 days) was approximately two times longer than that in the post-use removal group (656.28 days). The removal torques in the post-retention removal group (range, 4-5 N cm) were also higher than those in the post-use removal group. The mandible and pre-drilling groups demonstrated higher placement and removal torques than did the maxilla and no-drilling groups, respectively. In the no-drilling post-use removal group, the placement torque and microimplant length positively correlated with the removal torque. In the post-retention removal group, unloading in-bone stay period and microimplant diameter positively correlated with the removal torque in the no-drilling and pre-drilling methods, respectively. Conclusions: The removal torques differed according to the orthodontic loading and removal time of microimplants. With prolonged retention of microimplants inserted using the no-drilling method, the removal torque was clinically acceptable and positively correlated with the unloading in-bone stay period.

Microimplant mandibular advancement (MiMA) therapy for the treatment of snoring and obstructive sleep apnea (OSA) (코골이 및 수면 무호흡 치료를 위한 마이크로 임프란트를 이용한 하악골 전진술)

  • Ngiam, Joachim;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.40 no.2
    • /
    • pp.115-126
    • /
    • 2010
  • This case report describes the treatment of a 66 year old adult patient with a diagnosis of severe obstructive sleep apnea who was intolerant of nasal continuous positive airway pressure (nCPAP) treatment and oral appliance therapy. An alternative treatment of snoring and obstructive sleep apnea (OSA) with 2 orthodontic microimplants anchored to the mandible providing skeletal anchorage for mandibular advancement was implemented. After a 2 week healing period, a custom designed facemask provided extraoral anchorage to which the microimplants were connected to for titratable mandibular advancement. Microimplant Mandibular Advancement (MiMA) therapy resulted in resolution of the symptoms of severe OSA with a reduction of the apnea-hypopnea index (AHI), snoring and OSA symptoms.

Effect of surface anodization on stability of orthodontic microimplant

  • Karmarker, Sanket;Yu, Won-Jae;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.42 no.1
    • /
    • pp.4-10
    • /
    • 2012
  • Objective: To determine the effect of surface anodization on the interfacial strength between an orthodontic microimplant (MI) and the rabbit tibial bone, particularly in the initial phase aft er placement. Methods: A total of 36 MIs were driven into the tibias of 3 mature rabbits by using the self-drilling method and then removed aft er 6 weeks. Half the MIs were as-machined (n = 18; machined group), while the remaining had anodized surfaces (n = 18; anodized group). The peak insertion torque (PIT) and the peak removal torque (PRT) values were measured for the 2 groups of MIs. These values were then used to calculate the interfacial shear strength between the MI and cortical bone. Results: There were no statistical differences in terms of PIT between the 2 groups. However, mean PRT was significantly greater for the anodized implants ($3.79{\pm}1.39$ Ncm) than for the machined ones ($2.05{\pm}1.07$ Ncm) (p < 0.01). The interfacial strengths, converted from PRT, were calculated at 10.6 MPa and 5.74 MPa for the anodized and machined group implants, respectively. Conclusions: Anodization of orthodontic MIs may enhance their early-phase retention capability, thereby ensuring a more reliable source of absolute anchorage.

A Novel Treatment of Recurrent Temporomandibular Joint Dislocation with Intermaxillary Fixation Using Microimplant: A Case Report

  • Kee, In-Kyung;Byun, Jin-Seok;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.39 no.4
    • /
    • pp.156-162
    • /
    • 2014
  • Dislocation of temporomandibular joint (TMJ) is troublesome condition which was most commonly shown far anteriorly displaced mandibular condyle to the articular eminence, thereby make it impossible to close one's mouth. It is often referred to as 'open lock' in clinically. Although anatomical modification of the articular eminence through eminectomy has been considered most satisfactory and efffective treatment for managing the recurrent dislocation, it seldom performs clinically due to its invasiveness and patient's reluctance. We thought a shortterm intermaxillary fixation could be of benefit to the patient suffering from recurrent dislocation. A 21-year-old male patient with recurrent TMJ dislocation which had developed after excessive mouth opening, was successfully treated with intermaxillay fixation using microimplant for 2 months. It is more conservative and less complicated method than eminectomy in treating recurrent TMJ dislocation. Transient intermaxillary fixation using microimplant and elastics could be one of treatment options for recurrent TMJ dislocation.