• 제목/요약/키워드: Microbalance

검색결과 186건 처리시간 0.028초

Nonstoichiometry of the Terbium Oxide

  • Yo Chul Hyun;Ryu Kwang Sun;Lee, Eun Seok;Kim Keu Hong
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권1호
    • /
    • pp.33-36
    • /
    • 1994
  • The x values of nonstoichiometric chemical formula, $Tb_4O_{7-{\delta}}\;or\;TbO_{1.5+x}$, have been determined in temperature range from 600$^{\circ}$C to 1000$^{\circ}$C under oxygen partial pressure of 2 ${\times}$ 10$^{-1}$ to 1 ${\times}$ 10$^{-5}$ atm by using quartz microbalance. The x values varied from 0.0478 to 0.1964 in the above conditions. The enthalpy of formation for x' in TbO$_{1.5+(0.25-xo-x')}$, ${\delta}H_f$, was 4.93-3.40 kcal mol$^{-1}$ and the oxygen partial pressure dependence was -1/8.80∼-1/11.8 under these conditions. The electrical conductivity of the $TbO_{1.5+x}$ was measured under the same conditions and the values varied from about 10$^{-3}$ to 10$^{-6}\;{\Omega}^{-1}cm^{-1}$ within semiconductor range. The activation energies for the conduction increase with oxygen partial pressure from 0.83 to 0.89 eV under the above conditions. The l/n values obtained from the oxygen pressure dependence of the conductivity are 1/4.4-1/5.2. The conduction mechanism, defect structure, and other physical properties of the oxides are dicussed with the x values, the electrical conductivity values, and the thermodynamic data.

황화물 측정용 가스센서의 연구개발 (Development and research of gas sensor for monitoring sulfur compounds)

  • 김기영;김종민;함영환;장용근;김종득;장상목
    • 센서학회지
    • /
    • 제3권2호
    • /
    • pp.33-39
    • /
    • 1994
  • 냄새물질 특히, 환경오염물질의 측정을 위한 수정진동자를 이용한 센서 시스템을 수정진동자 표면에 여러가지 인지질과 활성탄 그리고 납계열 무기안료를 피막시켜 만들었다. 포스파티딜 콜린을 누적한 9MHz 수정진동자의 각종 유기가스에 대한 응답 특성을 살펴보았다. 인지질막의 특성에 기초한 서로 다른 냄새물질사이의 친화력에 대하여 설명할 수 있었다. 냄새물질은 누적한 지질막에 의존하는 공진주파수 변화 패턴과 응답면적에서 계산되어지는 상대적인 응답 세기를 서로 비교하여 확인할 수 있었다. 납계열 무기안료를 누적한 수정진동자를 이용하여 황화물의 검출이 가능함을 알 수 있었다. 이 결과, 여러가지 지질을 누적한 수정진동자를 이용하여 그 응답패턴을 비교한다면 냄새물질의 분석이 가능함을 알았다.

  • PDF

3가크롬 이온의 전착 반응에 용액 산도 및 유기물 첨가제가 미치는 영향 연구 (Investigation of the Effect of Solution Acidity and Organic Additives on the Electrodeposition of Trivalent Chromium Ions)

  • 이주열;;강대근;김만;권식철
    • 한국표면공학회지
    • /
    • 제43권6호
    • /
    • pp.297-303
    • /
    • 2010
  • The effect of solution acidity and organic additives, polyethylene glycol (PEG), on the trivalent chromium electroplating was systematically investigated in the view point of electroreduction of trivalent chromium ions and solution stability. It was found that solution acidity controlled at pH 2.5 showed the widest current range for bright electrodeposits in the presence of PEG additives, which reduced the local current intensification at high current densities. Through complex interaction between PEG additives and hydrogen ion, that is, solution acidity, electrode potential was moved in the negative direction in the bulk solution, while it shifted in the positive when electric potential was scanned. In conjunction with electrochemical quartz crystal microbalance (EQCM), it was found that PEG additives had a role in promoting the electron transfer to trivalent chromium ion complexes in bulk solution and their adsorption at the electrode surface as well as interfering with hydrogen ion reduction process below pH 2.5. The PEG additives developed the nodular morphology during electroreduction of trivalent chromium ions with the increase of solution acidity and enhanced its current efficiency by maintaining the consumption of complexant, formic acid, at low speed.

기능성 소화불량 환자에서 설태후박 및 흉늑각 측정의 진단적 가치 (Diagnostic Values of Tongue Coating Thickness and Sterno-costal Angle in Functional Dyspepsia)

  • 손지영;김진성
    • 대한한방내과학회지
    • /
    • 제35권2호
    • /
    • pp.157-174
    • /
    • 2014
  • Objectives : The aims of this study were to evaluate the diagnostic values of tongue coating thickness and sterno-costal angle as the quantitative diagnostic indicators in functional dyspepsia. Methods : We surveyed 60 functional dyspepsia patients recruited by the clinical trial, 'Clinical Trial for Evaluation on Availability of tongue diagnosis system (CTS-1000) : a Pilot study'. The patients were classified into three groups according to Rome III criteria for functional dyspepsia, and categorized into five groups according to Instrument of pattern identification for functional dyspepsia. Nepean dyspepsia index-Korean version (NDI-K) score, tongue coating thickness (percentage of tongue coating by tongue diagnosis system (CTS-1000), and weight of tongue coating by microbalance), sterno-costal angle, duration of illness and body mass index (BMI) were investigated. Results : Among the 5 types by instrument of pattern identification for functional dyspepsia, a significant difference of percentage of tongue coating was found. Percentage of tongue coating and weight of tongue coating showed significant correlation with total NDI-K score. Sterno-costal angle showed strong positive correlation with BMI and also showed significant difference between the non-overweight (BMI<23, n=32) and overweight ($BMI{\geq}23$, n=28) groups. Conclusions : Tongue coating thickness showed its potential as a new quantitative diagnostic indicator of functional dyspepsia. Further studies on the sterno-costal angle are anticipated to evaluate its potential as a new quantitative diagnostic indicator.

Physicochemical Characterization and Dissolution Properties of CS-891 with Different Crystallinity

  • Lee, Woo-Young;Park, Byoung-Woo;Park, Yong-Sun
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권4호
    • /
    • pp.279-285
    • /
    • 2005
  • Ground CS-891 (N-[1-(4-methoxyphenyl)-1-methylethyl]-3-oxo-4-aza-5a-androst-1-ene-$17{\beta}$-carboxamide) of poorly water soluble drug was obtained using a Heiko Seisakusho model TI-100 vibration mill, and samples with different crystallinity were prepared at mixture ratios of 10:0, 7:3, 5:5, 3:7 and 0:10 (intact;ground CS-891). Physicochemical characterizations were obtained using qualitative and quantitative X-ray diffractometry, different scanning calorimetry (DSC), scanning electron microscopy (SEM), Quantasorb surface area analyzer, and controlled atmosphere microbalance. With increase of amorphous CS-891 in mixture ratios, the intensities of X-ray diffraction peaks of crystalline CS-891 were decreased, whereas surface area, water absorption, and exothermic peaks in DSC were increased. The apparent solubility of ground CS-891 was $4.4\;{\mu}g/ml$ and the solubility of intact CS-891 was $3.1\;{\mu}g/ml$ at $37{\pm}1^{\circ}C$. The apparent precipitation rates of CS-891 in a supersaturated solution during the solubility test were increased with an increase of amorphous CS-891, and a crystalline form of CS-891 transformed from amorphous CS-891 after the solubility test was found by X-ray diffraction analysis, DSC and SEM. The dissolution profiles of CS-891 with different crystallinity at $37{\pm}1^{\circ}C$ by the USP paddle method were investigated, and the apparent dissolution rate constant of ground CS-891 was about 5.9-fold higher than that of intact CS-891. A linear relationships between the crystallinity of CS-891 and the apparent dissolution rate constant (r>0.96) were obtained.

Viologen 분자의 자기조립과 전기화학적 특성 (Self-Assembly and Electrochemical Properties of Viologen Particles)

  • 이동윤;박상현;신훈규;권영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.452-455
    • /
    • 2004
  • In this paper, investigations of the SAMs(self-assembled monolayers) of a thiol-fuctionalized viologen derivatives, $V_8SH$ and $SH_8V_8SH$, where, V is N,N'-dialkylbipyridinium (i.e. a viologen group), have been carried out by elucidate voltammetry date. The redox reactions are highly reversible and can be cycled many times without significant side reaction, which has been known as a nano-gram order mass detector through resonant frequency change self-assembly process of the viologen has been investigated with $QCM({\Delta}F)$. The assembling process of the $V_8SH$ and $SH_8V_8SH$ monolayers can be finished completely in about 1 hour. The measured frequency shift for $V_8SH$ and $SH_8V_8SH$ were about 351 and 172 Hz, respectively. From these values, we calculated that the mass adsorbed $V_8SH$ and $SH_8V_8SH$ were about 375 and 183 ng. We believe that this mass loss is caused by the simultaneous loss of the anions present within the monolayer for charge compensation of the viologen dications and some solvent.

  • PDF

자기 집합 단분자막 개질 금 전극을 이용한 수용액 중 폴리피를 성장에 관한 In-situ EQCM 연구 (In-situ EQCM Study on Growth of Polypyrrole Films Using Gold Electrodes Modified with Self-Assembled Monolayers in an Aqueous Solution)

  • 서경자;전일철
    • 전기화학회지
    • /
    • 제5권3호
    • /
    • pp.143-152
    • /
    • 2002
  • Self-assembled monolayer(SAM)로 변형된 금 전극 위로 폴리피롤의 전기화학적 석출 과정을 수용액 상태에서 in-situ EQCM (Electrochemical Quartz Crystal Microbalance)과 ex-situ AFM (Atomic Force Microscopy)을 이용하여 조사하였다. 금 전극에서 cyclic voltammetry로 살펴본 폴리머의 석출은 산화 제한 전위 (anodic limiting potential) 값에 매우 의존적이었으며 주사 횟수에는 의존하지 않았다. 제한 산화 전위가 0.8V (vs Ag | ArCl) 이상일 때 폴리머의 석출은 크게 증가하였다. 그리고 주사 횟수가 증가하면서 질량의 비이상적 변화가 관찰되었는데 이것은 폴리피롤 필름의 rearrangement가 원인이라고 생각된다. 1-dodecanethiol SAM 전극과 thiophene SAM전극에서는 폴리머가 3차원적으로 성장하며 필름의 rearrangement를 수반하였지만 BPUS $(Bis(\omega(N-pyrrolyl)-n-undecyl)disulfide)$ SAM 전극에서는 2차원적인 layer-by-layer 성장을 하고 필름의 rearrangement는 관찰되지 않았다. 폴리머가 급격하게 전극 면으로 석출되면 사슬 모양과 도너츠 모양의 폴리머를 만들며, 정류 상태에 이르면서 주름잡힌 폴리머 필름이 생성되는 것이 원자 힘 현미경 (Atomic Force Microscopy) 이미지로 관찰되었다.

진주시 대기중 PM10 및 PM2.5의 질량농도 특성 (Characterization of PM10 and PM2.5 Mass Concentrations in Jinju)

  • 박정호;박기형;서정민
    • 한국환경과학회지
    • /
    • 제23권12호
    • /
    • pp.1963-1970
    • /
    • 2014
  • Ambient particulate matters($PM_{10}$ and $PM_{2.5}$) were investigated at GNTECH university in Jinju city. Samples were collected using a dichotomous sampler(series 240, Andersen Corp.) and a TEOM(Tapered Element Oscillating Microbalance) monitor period from November 2012 to October 2013. For the dichotomous sampler measurements, daily 24-h integrated $PM_{2.5}$ and $PM_{10-2.5}$ ambient air samples were collected at a total flow rate of 16.7 L /min. For the TEOM monitor measurements, daily 1-h integrated $PM_{10}$ ambient air samples were collected at a flow rate of 16.7 L /min. The annual average concentrations of $PM_{10-2.5}$ and $PM_{2.5}$ by a dichotomous sampler were $10.0{\pm}6.1{\mu}g/m^3$ and $22.6{\pm}9.3{\mu}g/m^3$, respectively. And $PM_{10}$ concentration by dichotomous sampler were similar to TEOM monitor by $32.7{\pm}12.9{\mu}g/m^3$ and $31.7{\pm}11.3{\mu}g/m^3$, respectively. And good correlation ($R^2=0.964$) between the two methods was observed. The annual average of $PM_{2.5}/PM_{10}$ ratio was $0.70{\pm}0.12$.

Hemoglobin-DNA/pyterpy 박막을 이용한 과산화수소의 전기화학적 검출 (Electrochemical Detection of Hydrogen Peroxide based on Hemoglobin-DNA/pyterpy Modified Gold Electrode)

  • 이동윤;최원석;박상현;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1295-1296
    • /
    • 2008
  • Hydrogen peroxide ($H_2O_2$) biosensor is one of the most developing sensors because this kind of sensors is highly selective and responds quickly to the specific substrate. Hemoglobin (Hb) has been used as ideal biomolecules to construct hydrogen peroxide biosensors because of their high selectivity to $H_2O_2$. The direct electron transfer of Hb has widely investigated for application in the determination of $H_2O_2$ because of its simplicity, high selectivity and intrinsic sensitivity. An electrochemical detection for hydrogen peroxide was investigated based on immobilization of hemoglobin on DNA/Fe(pyterpy)$^{2+}$ modified gold electrode. The pyterpy monolayers were firstly an electron deposition onto the gold electrode surface of the quartz crystal microbalance (QCM). It is offered a template to attach negatively charged DNA. The fabrication process of the electrode was verified by quartz crystal analyzer (QCA). The experimental parameters such as pH, applied potential and amperometric response were evaluated and optimized. Under the optimized conditions, this sensor shows the linear response within the range between $3.0{\times}10^{-6}$ to $9.0{|times}10^{-4}$ M concentrations of $H_2O_2$. The detection limit was determined to be $9{\times}10^{-7}$ M (based on the S/N=3).

  • PDF

도시지역 사무실내 공기 중 환경담배연기의 측정 - 흡연이 부유먼지 농도에 미치는 영향을 중심으로 - (Measurement of Environmental Tobacco Smoke in the Air of Offices in Urban Areas - Focusing on the Impact of Smoking on the Concentrations of Suspended Particles -)

  • 백성옥;박상곤
    • 한국대기환경학회지
    • /
    • 제20권6호
    • /
    • pp.715-727
    • /
    • 2004
  • This study was carried out to evaluate non-smoker's exposure levels to environmental tobacco smoke (ETS) in the air of offices in urban areas. A total of 65 offices were selected from two large cities, i.e. Daegu and Daejeon. The field sampling was conducted repeatedly in summer (1999) and winter (1999~2000). The measured ETS markers included respirable suspended particles (RSP as PM$_{40}$ ), vapor and particulate phase ETS markers, including nicotine, 3-ethnyl pyridine (3-EP), ultraviolet absorbing particulate matter (UVPM), fluorescing particulate matter (FPM), and solanseol in ETS particles (SolPM). RSP was measured gravimetrically by a microbalance. The particle samples were then used for the determination of particulate ETS markers by HPLC, while vapor phase markers determined by GC/NPD. The analytical methods were validated for repeatability, linearity, detection limits, and duplication precision. The concentrations of RSP and other ETS markers were significantly higher in smoking offices than non-smoking offices. Despite the similar smoking strength in each office for different seasons, the concentration levels of ETS components appeared to be higher in winter than summer. The contributions of ETS to RSP concentrations based on SolPM, FPM, and UVPM methods were estimated to be in the range of 15.2 ~ 25.3% in smoking offices, whereas 2.4 ~ 15.9% in non-smoking offices. The cooling and heating types did not affect significantly the concentrations of RSP and other ETS markers. Finally, further research issues were suggested to obtain more scientific information on the non-smoker's exposure to ETS with respect to the frame of risk assessment..