Chemical Transformation of Individual Asian Dust Particles Estimated by the Novel Double Detector System of Micro-PIXE

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.106-114
    • /
    • 2010
  • By the application of novel double detector system of micro-PIXE that can detect light elements (Z<14), we made an attempt to provide a thorough discussion on the aging processes of Asian dust (hereafter called "AD") particle by reaction with sea-slat. The elemental spectra and maps obtained from the microbeam radiation of micro-PIXE to individual AD particles were useful for fractionating AD particles into both internally and externally mixed particles. A spatial distribution of elements in a minute domain of single particle obtained by scanning the microbeam irradiation enabled us not only to estimate the chemical mixing state of individual AD particles but also to presume their aging processes in both ambient air and cloud. By calculating the normalized micro-PIXE net count of elements, it was possible to classify individual AD particles into three distinct groups (i.e., (1) Aging type 1: AD particle coated by the gaseous Cl evaporated by the reaction between artificial acids and sea salt; (2) Aging type 2: AD particle mixed with sea salt but no additional reaction with artificial acids; and (3) Non-aged type) A relatively high transformation rate (63.3-75.9%) was shown in large particles (greater than $5.1\;{\mu}m$ in diameter).

Preparation and Properties of Waterborne Polyurethane-Urea/Poly(vinyl alcohol) Blends for High Water Vapor Permeable Coating Materials

  • Yun, Jong-Kook;Yoo, Hye-Jin;Kim, Han-Do
    • Macromolecular Research
    • /
    • v.15 no.1
    • /
    • pp.22-30
    • /
    • 2007
  • High water vapor permeable coating materials were prepared by blending aqueous poly(vinyl alcohol) (PVA) solution with waterborne polyurethane-urea (WBPU) dispersions synthesized by prepolymer mixing process. Stable WBPU/PVA dispersions were achieved at PVA content below 30 wt%. As the water soluble polymer PVA content increased, the number and density of total micro-pores (tunnel-like/isolated micro-pores) formed after the dissolution of PVA in water increased, and the water vapor permeability of coated Nylon fabric also increased significantly. Using WBPU/water soluble polymer PVA blends as a coating material and then dissolving PVA in water was confirmed to be an effective method to obtain prominent breathable fabrics.

Mechanical Properties for Micro-and-Nano- Mixture Composites Based Epoxy Resins (에폭시기반 마이크로 그러고 나노입자가 혼합된 콤포지트의 기계적특성)

  • Kwon, Sun-Suk;Choi, Bo-Sung;Baek, Kwan-Hyun;Lee, Chang-Hoon;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.84-84
    • /
    • 2010
  • Nano particles (10nm SiO2) were silane-treated in order to modify the surface characteristics in a epoxy nanocomposite. Then. micro particles ($3{\mu}m$ SiO2) were poured into the epoxy nanocomposite using various mixing process and epoxy/ micro-and-nano- mixed composites (EMNC) were prepared. The thermal (Tg) and mechanical (tensile and flexural strength) properties were measured by DMA and UTM and the data was estimated by Weibull plot.

  • PDF

Flow Visualization in a new CSC micromixer (새로운 CSC micromixer 를 이용한 유동가시화)

  • Singh, Kanika;Kim, Hyun-Hoon;Min, Young-Uk;Kim, Hyung-Dong;Kim, Kyung-Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.63-65
    • /
    • 2007
  • The paper reports on a new type of combinatorial chaotic and serpentine micromixer. Such a new and novel micromixer is simple to fabricate and easy to use. The micromixer is characterized and visualized with the help of the Micro-LIF technique. The new micromixer will e further applied to lab-on-chip device. The mixing capabilities of this mixer is about 30-33%.

  • PDF

Mixing in a Microchannel by using Induced-charge Electro-osmosis (마이크로 채널 내 유도-전하 전기삼투에 의한 혼합)

  • Jeon, Young-Hun;Heo, Young-Gun;Jung, Won-Hyuk;Alapati, Suresh;Suh, Yong-Kweon
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.4
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents an experimental study on the performance of a micro-mixer using AC electro-osmotic flow. The microchannel is made of PDMS for the side and top walls and glass patterned with ITO for the bottom wall. We first investigated the effect of the applied potential as well as the frequency on the slip velocity. We have found that the slip velocity is roughly proportional to the applied voltage in line with the Helmholtz-Smoluchowski equation and there is an optimum frequency at which the slip velocity becomes maximized. To find the optimum parameters for mixing device we tested our device for various design parameters. It turned out that the best mixing effect is obtained approximately when the electrode angle is $30^{\circ}$, electrode width $200\;{\mu}m$, and the frequency of power supply 700 Hz.

Manufacturing of Micro Gas Bearing by Fe-Ni Nanopowder and Metal Mold Using LIGA (LIGA 금형몰드를 이용한 Fe-Ni계 나노분말의 초미세 가스베어링 제조)

  • Son, Soo-Jung;Cho, Young-Sang;Kim, Dae-Jung;Kim, Jong-Hyun;Chang, Suk-Sang;Choi, Chul-Jin
    • Journal of Powder Materials
    • /
    • v.19 no.2
    • /
    • pp.140-145
    • /
    • 2012
  • This paper describes the manufacturing process of tilting pad gas bearing with a diameter of 5 mm and a length of 0.5-1 mm for power MEMS (Micro Electomechanical Systems) applications. The bearing compacts with nanopowder feedstock were prepared by Ni-metal mold with 2-mold system using LIGA process. The effect of the manufacturing conditions on sintering properties of nanopowder gas bearing was investigated. In this work, Fe-45 wt%Ni nanopowder with an average diameter of 30-50 nm size was used as starting material. After mixing the nanopowder and the wax-based binders, the amount of powder was controlled to obtain the certain mixing ratio. The nanopowder bearing compacts were sintered with 1-2 hr holding time under hydrogen atmospheres and under temperatures of $600^{\circ}C$ to $1,000^{\circ}C$. Finally, the critical batch of mixed powder system was found to be 70% particle fraction in total volume. The maximum density of the sintered bearing specimen was about 94% of theoretical density.

Optimization of Wavefront Coding Phase Mask Applied to 5X-40X Micro-Objectives Simultaneously

  • Liu, Jiang;Miao, Erlong;Sui, Yongxin;Yang, Jianghuai
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.487-493
    • /
    • 2015
  • A wavefront coding (WFC) technique provides an extension of the depth of field for a microscopy imaging system with slight loss of image spatial resolution. Through the analysis of the relationship between the incidence angle of light at the phase mask and the system pupil function, a mixing symmetrical cubic phase mask (CPM) applied to 5X-40X micro-objectives is optimized simultaneously based on point-spread function (PSF) invariance and nonzero mean values of the modulation transfer function (MTF) near the spatial cut-off frequency. Optimization results of the CPM show that the depth of field of these micro-objectives is extended 3-10 times respectively while keeping their resolution. Further imaging simulations also prove its ability in enhancing the defocus imaging.

Effect of Particle Size and Mixing Ratio on Quality of Fluidized Coated Vitamin C (입자크기와 혼합비에 따른 유동층 코팅 비타민 C의 품질 특성)

  • Park, Su-Jung;Hwang, Sung-Hee;Chung, Hun-Sik;Youn, Kwang-Sup
    • Food Science and Preservation
    • /
    • v.14 no.4
    • /
    • pp.364-368
    • /
    • 2007
  • The purpose of this study was to improve the stability and the processing property of vitamin C. Vitamin C was coated according to particle size(80-100 mesh, 100-140 mesh) and mixing ratio(1:1.6, 1:2.5, 1:3(w/w)) with coating solution(8% Zein-DP, 6% HPMC-FCC), and then the quality characteristics of fluidized bed micro coated vitamin C were investigated. The coating efficiency and the thickness of coating film were higher in $80{\sim}100$ mesh particle than in $100{\sim}140$ mesh particles, and coating efficiency was decreased as the coating material was increased. The distribution range of particle was more narrow in mixing ratio of 1:3(w/w) than in the other. DPPH radical scavenging activity was not affected by the particle size and the mixing ratio. There was no difference between the coating materials in terms of the quality characteristics. The optimum coating condition for fluidized bed micro-coating of vitamin C powder was selected as the particle size of $80{\sim}100$ mesh and the mixing ratio with coating solution of 1:3(w/w).

A Study About Biochip Combined with Micro Mixer and Reactor for DNA Ligation (마이크로 혼합기와 반응기로 구성된 DNA 결찰용 바이오칩에 관한 연구)

  • Kang, Do-Hyoung;Ahn, Yoo-Min;Hwang, Seung-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.8
    • /
    • pp.624-632
    • /
    • 2008
  • In this research, we developed new PDMS-glass based microbiochip consisted of the micromixer and microreactor for DNA ligation. The micromixer was composed of a straight channel integrated with nozzles and pillars, and the microreactor was composed of a serpentine channel. We coated the PDMS chip surface with the 0.25wt.% PVP solution to prevent the bubble generation which was caused by the hydrophobicity of the PDMS. The new micomixer was passive type and the mixing was enhanced by a convective diffusion using the nozzle and pillar. The 10.33mm long micromixer showed the good mixing efficiency of 87.7% at 500 l/min flow rate. We could perform the DNA ligation successfully in the microbiochip, and the ligation time was shortened from 4 hours in conventional laboratory method to 5 min in the microbiochip.

A Study on the curvature Effect of microchannel within Electroosmotic Flow (전기삼투 유동 중 마이크로 채널 내 곡률 변화에 따른 혼합특성에 대한 연구)

  • Heo, Hyeung-Seok;Suh, Yong-Kweon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.107-110
    • /
    • 2005
  • In this study a newly designed and electro-osmotic micro-mixer is proposed. This design is comprised of a channel and metal electrodes attached in the local side wall surface, To investigate the flow patterns a numerical method is employed. To obtain the flow patterns numerical computation are performed by using a commercial code, CFD-ACE. The fluid-flow solutions are then cast into studying the characteristics of stirring with aid the Mixing index. Focus is given the effect on the electro osmotic flow characteristics under the curvature variation in the microchannel with the local of the electric field

  • PDF