• 제목/요약/키워드: Micro-level

검색결과 1,291건 처리시간 0.05초

잠겨진 물체를 포함하는 계면유동의 수치적인 연구 (Numerical Study of Interfacial Flows With Immersed Solids)

  • 김성일;손기헌
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.706-711
    • /
    • 2003
  • A numerical method is presented for computing unsteady incompressible two-phase flows with immersed solids. The method is based on a level set technique for capturing the phase interface, which is modified to satisfy a contact angle condition at the solid-fluid interface as well as to achieve mass conservation during the whole calculation procedure. The modified level set method is applied for numerical simulation of bubble deformation in a micro channel with a cylindrical solid block and liquid jet from a micro nozzle.

  • PDF

높은 입사 음압에서의 미세 천공판을 이용한 흡음 기구의 설계 (Design of a Micro-perforated Panel Absorber at High Incident Sound Pressure)

  • 박순홍;서상현;장영순
    • 한국소음진동공학회논문집
    • /
    • 제20권10호
    • /
    • pp.983-990
    • /
    • 2010
  • Reduction of acoustic loads of space launch vehicles can be achieved by acoustic absorbers satisfying strict cleanness requirements. This limited the use of general porous materials and requires non-porous sound absorbers. Micro-perforated panel absorbers(MPPA) is one of promising sound absorbers satisfying the cleanness requirement for launch vehicles. However, its applicability was limited to low sound pressure levels according to the acoustic impedance model of micro-perforated panels. In this paper the applicability of micro-perforated panel absorbers at high incident sound pressure was investigated in experimental ways. The absorption characteristics of a micro-perforated panel absorber was simulated according to its design variables, e.g., minute hole diameters and aperture ratios. It was shown that optimal design can be readily done by using proposed design charts. Experiments were conducted to measure acoustic properties of the designed micro-perforated panel absorbers. The results showed that acoustic resistance increases rapidly as incident sound pressure level does but change of acoustic reactance can be neglected in a practical point of view. This caused the decrease of peak value of absorption coefficient at high incident sound pressure level, but the amount of reduction can be accepted in practice. The major advantage of the micro-perforated panel absorber(wide absorption bandwidth) was still kept at high sound pressure level.

바이오 셀 및 마이크로 부품 handling을 위한 pneumatic line을 갖는 in-plane 형 마이크로 압전 그리퍼 제조 및 특성 (Fabrication and Characteristics of In-Plane Type Micro Piezoelectric Micro Grippers with Pneumatic Lines for Biological Cells and Micro Parts Handling)

  • 박준식;박광범;신규식;문찬우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.501-502
    • /
    • 2006
  • In-plane type micro piezoelectric micro grippers with pneumatic lines for manipulation biological cells and micro parts were designed, fabricated, and characterized. Micro grippers were fabricated through the final micro-sanding process after wafer level bonding between the etched 4' Si wafer with pneumatic channels and 4' glass wafer. Displacements between two jaws of fabricated micro grippers were linearly increased with applying voltages to piezoelectric actuator. In the case of applying 80 V, the displacement between two jaws was $160{\mu}m$. Using fabricated micro grippers, manipulation tests for biological cell and micro parts with the sizes less than $100{\mu}m$ are in process.

  • PDF

Investigations on aerosols transport over micro- and macro-scale settings of West Africa

  • Emetere, Moses Eterigho
    • Environmental Engineering Research
    • /
    • 제22권1호
    • /
    • pp.75-86
    • /
    • 2017
  • The aerosol content dynamics in a virtual system were investigated. The outcome was extended to monitor the mean concentration diffusion of aerosols in a predefined macro and micro scale. The data set used were wind data set from the automatic weather station; satellite data set from Total Ozone Mapping Spectrometer aerosol index and multi-angle imaging spectroradiometer; ground data set from Aerosol robotic network. The maximum speed of the macro scale (West Africa) was less than 4.4 m/s. This low speed enables the pollutants to acquire maximum range of about 15 km. The heterogeneous nature of aerosols layer in the West African atmosphere creates strange transport pattern caused by multiple refractivity. It is believed that the multiple refractive concepts inhibit aerosol optical depth data retrieval. It was also discovered that the build-up of the purported strange transport pattern with time has enormous potential to influence higher degrees of climatic change in the long term. Even when the African Easterly Jet drives the aerosols layer at about 10 m/s, the interacting layers of aerosols are compelled to mitigate its speed to about 4.2 m/s (macro scale level) and boost its speed to 30 m/s on the micro scale level. Mean concentration diffusion of aerosols was higher in the micro scale than the macro scale level. The minimum aerosol content dynamics for non-decaying, logarithmic decay and exponential decay particulates dispersion is given as 4, 1.4 and 0 respectively.

전해-자기 복합 가공을 이용한 마이크로 채널 디버링공정 최적화 (A Study on the Optimization of Deburring Process for the Micro Channel using EP-MAP Hybrid Process)

  • 이성호;곽재섭
    • 한국생산제조학회지
    • /
    • 제22권2호
    • /
    • pp.298-303
    • /
    • 2013
  • Magnetic abrasive polishing is one of the most promising finishing methods applicable to complex surfaces. Nevertheless this process has a low efficiency when applied to very hardened materials. For this reason, EP-MAP hybrid process was developed. EP-MAP process is expected to machine complex and hardened materials. In this research, deburring process using EP-MAP hybrid process was proposed. EP-MAP deburring process is applied to micro channel, thereby it can obtain both deburring process and polishing process. EP-MAP deburring process on the micro channel was performed. Through design of experiment method, error of height in this process according to process parameter is analyzed. When the level 1 parameter A(magnetic flux density) and level 2 parameter B(electric potential), C(working gap) and level 3 parameter D(feed rate) are applied in the deburring process using EP-MAP hybrid process, it provides optimum result of EP-MAP hybrid deburring process.

A Study on the Effective Downscaling Methodology for Design of a Micro Smart Grid Simulator

  • Ko, Yun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1425-1437
    • /
    • 2018
  • In this paper, a methodology was proposed to reduce the electrical level and spatial size of the smart grid with distributed generations (DGs) to a scale in which the electrical phenomena and control strategies for disturbances on the smart grid could be safely and freely experimented and observed. Based on the design methodology, a micro smart grid simulator with a substation transformer capacity of 190VA, voltage level of 19V, maximum breaking current of 20A and size of $2{\times}2m^2$ was designed by reducing the substation transformer capacity of 45MVA, voltage level of 23kV and area of $2{\times}2km^2$ of the smart grid to over one thousandth, and also reducing the maximum breaking current of 12kA of the smart grid to 1/600. It was verified that the proposed design methodology and designed micro smart grid simulator were very effective by identifying how all of the fault currents are limited to within the maximum breaking current of 20A, and by confirming that the maximum error between the fault currents obtained from the fault analysis method and the simulation method is within 1.8% through the EMTP-RV simulation results to the micro smart grid simulator model.

Deep cavity를 가진 Cap Wafer와 MEMS 소자의 Polymer Wafer bonding (Polymer Wafer bonding of MEMS device and Cap Wafer with deep cavity)

  • 이현기;박태준;윤상기;박남수;박형재;민종환;이영규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1702-1703
    • /
    • 2011
  • MEMS 소자의 Wafer level Package 관련하여 Deep cavity를 가진 Cap Wafer와 Polymer bonding 중 cavity 단차로 인한 Polymer Patterning 및 접합 불량의 어려움을 극복할 수 있는 새로운 공정 flow를 제안하였다. Cavity를 형성할 때 사용하는 Si deep etching Mask인 기존의 Photoresist를 접합용 감광성 Polymer로 대체하고, cavity 형성 후, 별도의 추가 공정 없이 이 Polymer를 이용해 Wafer bonding을 진행하였다. 이를 통해 cavity 단차에 따른 문제를 해결함과 동시에 공정이 단순하고 제작 비용이 저렴하며, 신뢰성 있는 Wafer level Package를 구현하였다.

  • PDF

Thermopiezoelectric Cantilever for Probe-Based Data Storage System

  • Jang, Seong-Soo;Jin, Won-Hyeog;Kim, Young-Sik;Cho, Il-Joo;Lee, Dae-Sung;Nam, Hyo-Jin;Bu, Jong. U.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권4호
    • /
    • pp.293-298
    • /
    • 2006
  • Thermopiezoelectric method, using poly silicon heater and a piezoelectric sensor, was proposed for writing and reading in a probe based data storage system. Resistively heated tip writes data bits while scanning over a polymer media and piezoelectric sensor reads data bits from the self-generated charges induced by the deflection of the cantilever. 34${\times}$34 array of thermopiezoelectric nitride cantilevers were fabricated by a single step wafer level transfer method. We analyzed the noise level of the charge amplifier and measured the noise signal. With the sensor and the charge amplifier 20mn of deflection could be detected at a frequency of 10KHz. Reading signal was obtained from the cantilever array and the sensitivity was calculated.

축류 마이크로 홴의 전산해석 및 성능시험 (A Numerical Analysis and Experiment for Micro-Fans)

  • 조진수;변태균;박왕식;전창근
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.895-906
    • /
    • 2000
  • A three dimensional linear frequency-domain lifting surface panel method was used for the aerodynamic analysis of axial flow type micro-fans. As proven by the duct modeling, the tip clearance of the micro-fans tested is large enough to ignore the calculated effect of the duct system. As the numerical results and experimental data agreed well in the operating point region, the method was applicable in the parametric studies to determine the design parameters of axial flow fans. Experiments on micro-fans were carried out based on KS B 6311. The newly designed micro-fan showed improvements in both static pressure rise and volumetric flow rate compared to the existing fans at a given operating condition. No detection of surging and the smooth characteristic curve proved the improvement in performance. To reduce the fan noise in the fan design, it was necessary to make use of the frequency spectrum analysis data. Measurement of sound pressure level for micro-fans was conducted based on KS B 6361 and KS A 0705. The peak - which occurs at blade passage frequency and its higher harmonics due to the fan noise - was not detected. This justifies the design methodology of the blade.

SWOT분석을 통한 한국 마이크로 로봇의 발전방안 (The Study of SWOT(Strength-Weakness-Opportunity-Threat) Analysis for Micro-robot Technology Development and Trend of S. Korea)

  • 이상윤;윤홍주
    • 한국전자통신학회논문지
    • /
    • 제7권4호
    • /
    • pp.881-895
    • /
    • 2012
  • 마이크로 로봇은 인간의 다양한 질병과 진단에 있어 유용한 도구로서 활용이 가능한데, 이러한 이유로 현재 세계의 많은 국가들은 마이크로 로봇의 제작과 개발에 관심을 기울이고 있다. 한국정부 역시 이러한 세계적 추세 속에서, 마이크로 로봇 개발에 대한 기술정책을 만들고 많은 노력을 하고 있다. 따라서 본고는 SWOT분석을 통해, 한국의 마이크로 로봇 기술동향과 개발현황을 분석하여 미래 한국의 마이크로 로봇에 대한 가장 합당한 발전방안을 모색한다. 연구결과, '박테리아 기반기술의 마이크로 로봇(C형-2)'과 '무배터리 자체추진기 자율이동 마이크로 로봇(C형-3)'과 같은, 한국에서 관련 최신 특허로 등록받은 마이크로 로봇에 대한 보다 집중적인 지원이 필요하며, 이 양 분야 모두 현재 세계적인 수준으로 성장하고 있으므로 지원 중인 마이크로 로봇 개발에 관한 예산을 더욱 늘리는 한편 보다 적극적으로 관련 기술개발을 추진해야 한다.