• 제목/요약/키워드: Micro-cone

검색결과 71건 처리시간 0.02초

Micro-computed tomographic evaluation of single-cone obturation with three sealers

  • Sahar Zare;Ivy Shen;Qiang Zhu;Chul Ahn;Carolyn Primus;Takashi Komabayashi
    • Restorative Dentistry and Endodontics
    • /
    • 제46권2호
    • /
    • pp.25.1-25.12
    • /
    • 2021
  • Objectives: This study used micro-computed tomography (µCT) to compare voids and interfaces in single-cone obturation among AH Plus, EndoSequence BC, and prototype surface pre-reacted glass ionomer (S-PRG) sealers and to determine the percentage of sealer contact at the dentin and gutta-percha (GP) interfaces. Materials and Methods: Fifteen single-rooted human teeth were shaped using ProTaper NEXT size X5 rotary files using 2.5% NaOCl irrigation. Roots were obturated with a single-cone ProTaper NEXT GP point X5 with AH Plus, EndoSequence BC, or prototype S-PRG sealer (n = 5/group). Results: The volumes of GP, sealer, and voids were measured in the region of 0-2, 2-4, 4-6, and 6-8 mm from the apex, using image analysis of sagittal µCT scans. GP volume percentages were: AH Plus (75.5%), EndoSequence BC (87.3%), and prototype S-PRG (94.4%). Sealer volume percentages were less: AH Plus (14.3%), EndoSequence BC (6.8%), and prototype S-PRG (4.6%). Void percentages were AH Plus (10.1%), EndoSequence BC (5.9%), and prototype S-PRG (1.0%). Dentin-sealer contact ratios of AH Plus, EndoSequence BC, and prototype S-PRG groups were 82.4% ± 6.8%, 71.6% ± 25.3%, and 70.2% ± 9.4%, respectively. GP-sealer contact ratios of AH Plus, EndoSequence BC, and prototype S-PRG groups were 65.6% ± 29.1%, 80.7% ± 25.8%, and 87.0% ± 8.6%, respectively. Conclusions: Prototype S-PRG sealer created a low-void obturation, similar to EndoSequence BC sealer with similar dentin-sealer contact (> 70%) and GP-sealer contact (> 80%). Prototype S-PRG sealer presented comparable filling quality to EndoSequence BC sealer.

Anti-Inflammatory Activity of Pinus koraiensis Cone Bark Extracts Prepared by Micro-Wave Assisted Extraction

  • Kang, Sun-Ae;Kim, Dong-Hee;Hong, Shin-Hyub;Park, Hye-Jin;Kim, Na-Hyun;Ahn, Dong-Hyun;An, Bong-Jeun;Kwon, Joong-Ho;Cho, Young-Je
    • Preventive Nutrition and Food Science
    • /
    • 제21권3호
    • /
    • pp.236-244
    • /
    • 2016
  • In this study, we compared the anti-inflammatory activity of Pinus koraiensis cone bark extracts prepared by conventional extraction and microwave-assisted extraction (MAE). Water extracts and 50% ethanol extracts prepared using MAE were applied to RAW 264.7 cell at 5, 10, 25, and $50{\mu}g/mL$ of concentrations, and tested for cytoxicity. The group treated with $50{\mu}g/mL$ of 50% ethanol extracts showed toxicity. In order to investigate the inhibition of nitric oxide (NO) production in RAW 264.7 cells, extracts of water and ethanol were treated with 5, 10, and $25{\mu}g/mL$ concentrations. The inhibitory activity of water and 50% ethanol extracts groups were determined as 40% and 60% at $25{\mu}g/mL$ concentration, respectively. We found concentration dependent decreases on inducible NO synthase. The inhibitory effect against forming inflammatory cytokines, prostaglandin $E_2$, tumor necrosis factor-${\alpha}$, interleukin (IL)-6, and IL-$1{\beta}$, was also superior in the $25{\mu}g/mL$ treated group than the control group. According to these results, the water extracts and 50% ethanol extracts both inhibited inflammatory mediators by reducing the inflammatory response. Therefore, The MAE extracts of P. koraiensis cone bark can be developed as a functional ingredient with anti-inflammatory activity.

초소형 관입시험기를 이용한 지반공동 주변지반의 이완영역탐지를 위한 실험적 연구 (An Experimental Study on the Detection of Loosened Areas in a Ground cavity Using a Micro Penetration Test)

  • 김호연;김영호;박윤석;유승경;한중근
    • 한국지반신소재학회논문집
    • /
    • 제18권4호
    • /
    • pp.299-306
    • /
    • 2019
  • 본 연구에서는 층 다짐으로 조성된 지반을 모사한 모형실험에서 지반 공동 발생 시 지반의 이완영역 범위를 추정하기 위해 제작된 이완영역탐지기를 통해 이완영역을 측정하고자 하였다. 세립분과 조립질 토사를 조성한 층상구조로 구성된 지반에 대해 콘 직경의 크기에 따라 영향을 받는 것을 확인하였으며, 이에 따른 적절한 콘을 선정하기 위해 크기효과 실험을 수행한 결과 적절한 초소형콘을 설정할 수 있었다. 또한, 본 연구에서 적용된 LAD를 이용하는 경우 실내모형실험 지반의 다짐정도에 따른 경계면 및 상대밀도 차에 의한 관입저항치의 급격한 변화에 따라 지반의 이완상태를 파악할 수 있었다. 지반내 관입저항특성을 통해 공동주변부에서 발생하는 이완영역의 범위를 추정하였으며, 이완영역에서 관입저항력의 감소율을 통해 파괴 발생 영역을 확인하였다.

전단파, 전자기파 및 콘 관입저항력을 이용한 직접전단실험시 전단영역 특성 평가 (Evaluation of Shear Zone in Direct Shear Test Using Elastic, Electromagnetic Waves and Cone Tip Resistance)

  • 변용훈;쭝꽝훙;짠밍콰;이종섭
    • 한국지반공학회논문집
    • /
    • 제27권2호
    • /
    • pp.43-52
    • /
    • 2011
  • 조립토로 구성된 지반구조물의 안정성은 전단변형에 따른 전단영역의 특성변화에 의해 영향을받는다. 본 연구의 목적은 전단파와 전기비저항 및 콘 선단저항력을 이용하여 직접전단실험시 발생하는 전단영역의 특성을 파악하는 것이다. 전단영역의 특성을 파악하기 위하여, 아크릴 재질로 직접전단상자를 제작하였으며, 직접전단상자의 벽면에는 전단파와 전기비저항의 측정을 위하여 벤더엘리먼트와 전기비저항 프로브를 설치하였다. 벤더엘리먼트와 전기비저항 프로브는 전단영역과 비전단영역에 각각 설치되어, 전단변형에 따른 조립토의 거동을 비교할 수 있도록 하였다. 또한, 콘 선단저항력을 측정할 수 있도록 개발한 마이크로 콘을 첨두강도상태와 잔류강도상태에서 관입하여 깊이에 따른 시료의 강도분포를 관찰하였다. 실험결과, 바닥부근과 하부전단영역에서는 전단변형에 따른 전단파 속도는 일정하였지만, 상부전단영역에서의 전단파 속도는 증가하였다. 또한, 바닥부근의 전기비저항은 변화가 없는 반면, 하부전단영역에서 전기비저항은 상대밀도에 따라 수직변형률과 반비례관계로 나타났다. 콘 선단저항력의 변화도 전단파 속도의 변화와 유사하게 상부전단영역에서 큰 변화가 관찰되었다. 본 논문에서 제시한 직접전단실험시 전단파와 전기비저항을 관찰하는 것과 실험완료 후 콘 관입실험은 조립토의 전단영역 특성을 파악하기 위한 매우 효과적인 방법이 될 수 있음을 보여준다.

홈노즐을 이용한 정전분무 확산 연소 특성에 관한 연구 (Characteristics of the electrospraying combustion using grooved nozzle)

  • 김우진;김경태;김상수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2366-2371
    • /
    • 2007
  • Spray combustion characteristics of a conducting fuel electrospray have been studied for clean combustion technology. The multiplexing system which can retain the characteristics of the cone-jet mode is inevitable for the electrospray application. Charged micro droplets can be obtained in almost uniform size during operating the electrospray in the cone-jet mode. This experiment device set up the multiplexed grooved nozzle system with the extractor. Using the grooved nozzle, the stable cone-jet mode can be achieved at the each groove in the grooved mode. This electrospray system was applied to the diffusion combustion. It is the first step to discover the diffusion combustion characteristics of the electrospray. In case of the single grooved nozzle electrospray, the diffusion flames are occurred at each jet of grooved mode and they are quite stable. The exhaust gas analysis was indicated that there is the critical point which can make very stable diffusion combustion.

  • PDF

Electrostatic Interference Model of EHD Spraying from an Array of Cone Jets in Electrospray Micro-Thruster

  • ;변도영;김만영
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.30-33
    • /
    • 2006
  • Onset voltage plays a crucial role in the design of a spray microthruster. This paper presents an analytical electrostatic model to predict the behavior of onset voltage in an array of emitters. The basic idea of this method is to superimpose the electric potentials obtained from each individual emitter in an array of emitters. The results show that if one emitter operates and the other neighboring emitters are dry, the potential required for cone-jet spraying generally increases as the emitter spacing decreases (due to electrical shielding). However at very close spacing the potential can decrease. If all emitters operate at the same time, the phenomenon that even at very close spacing the onset voltage required for cone-jet spraying increases merely as the emitter spacing decreases.

  • PDF

사각뿔/원뿔 형상의 마이크로 니들 가공 기술 개발 (The Development of a machining technology on the micro needle pattern with a quadrangular pyramid or cone shapes)

  • 최규완;장성호
    • Design & Manufacturing
    • /
    • 제10권3호
    • /
    • pp.25-29
    • /
    • 2016
  • Recently, a hyaluronic acid micro needle patch for therapeutic and cosmetic purposes has been used by attaching directly to the skin with a pattern having a micro needle shape of 1/3 thickness of hair. These products are attracting attention as an innovative product that maximizes the effect by activating the active ingredient in the skin in the deep skin without blocking the horny layer because the micro needle shape exists on the patch surface so that it can penetrate effectively to the skin. Currently, DAB (droplet air blowing) or MEMS technology is used to make pattern shapes for patches. Because of this technology, manufacturing time is long and manufacturing cost is high, so we tried to develop the mold technology to machine the microneedle shape directly to the metal. In this study, we first fabricated a needle pattern with a quadrangular pyramid shape and finally produced a conical needle pattern.

미세 수관 노즐의 전기유체역학적 수적 분사특성 (Electrohydrodynamic Water Droplet Ejection Characteristics from a Micro-Water-Nozzle)

  • 문재덕
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1632-1637
    • /
    • 2010
  • A micro-water-nozzle, as one of a cooling means of micro-electronic devices, has been proposed and investigated. The I-V characteristics of the micro-water-nozzle and effect of applied voltage on the meniscus formation and deformation and ejection processes of de-ionized water on the micro-water-nozzle tip have been investigated. The water ejection processes, such as a drop formation, a drop deformation, a dripping, a cone jet, and an atomization, were taken place on the micro-water-nozzle tip by the electrohydrodynamic forces acted by the DC and AC high voltages applied on the meniscus of the micro-water-nozzle tip. The I-V characteristics of the micro-water-nozzle-to-plate electrode system were different from that of the same metal-point electrode system, due to the meniscus formation and water droplet ejection at the nozzle tip. The positive and negative DC and AC high voltages showed the water droplets ejection, the ejection rates of 1.8, 1.5 and 1.2 g/h respectively, which, however, showed that the proposed micro-water-nozzle-to-plate electrode system could be used as one of an effective pumping means.

CBCT-based assessment of root canal treatment using micro-CT reference images

  • Lamira, Alessando;Mazzi-Chaves, Jardel Francisco;Nicolielo, Laura Ferreira Pinheiro;Leoni, Graziela Bianchi;Silva-Sousa, Alice Correa;Silva-Sousa, Yara Terezinha Correa;Pauwels, Ruben;Buls, Nico;Jacobs, Reinhilde;Sousa-Neto, Manoel Damiao
    • Imaging Science in Dentistry
    • /
    • 제52권3호
    • /
    • pp.245-258
    • /
    • 2022
  • Purpose: This study compared the root canal anatomy between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) images before and after biomechanical preparation and root canal filling. Materials and Methods: Isthmus-containing mesial roots of mandibular molars(n=14) were scanned by micro-CT and 3 CBCT devices: 3D Accuitomo 170 (ACC), NewTom 5G (N5G) and NewTom VGi evo (NEVO). Two calibrated observers evaluated the images for 2-dimensional quantitative parameters, the presence of debris or root perforation, and filling quality in the root canal and isthmus. The kappa coefficient, analysis of variance, and the Tukey test were used for statistical analyses(α=5%). Results: Substantial intra-observer agreement (κ=0.63) was found between micro-CT and ACC, N5G, and NEVO. Debris detection was difficult using ACC (42.9%), N5G (40.0%), and NEVO (40%), with no agreement between micro-CT and ACC, N5G, and NEVO (0.05<κ<0.12). After biomechanical preparation, 2.4%-4.8% of CBCT images showed root perforation that was absent on micro-CT. The 2D parameters showed satisfactory reproducibility between micro-CT and ACC, N5G, and NEVO (intraclass correlation coefficient: 0.60-0.73). Partially filled isthmuses were observed in 2.9% of the ACC images, 8.8% of the N5G and NEVO images, and 26.5% of the micro-CT images, with no agreement between micro-CT and ACC, and poor agreement between micro-CT and N5G and NEVO. Excellent agreement was found for area, perimeter, and the major and minor diameters, while the roundness measures were satisfactory. Conclusion: CBCT images aided in isthmus detection and classification, but did not allow their classification after biomechanical preparation and root canal filling.

고유량 정전분무를 위한 다중 홈노즐 특성 연구 (Characteristics of Multiplexed Grooved Nozzles for High Flow Rate Electrospray)

  • 김경태;김우진;김상수
    • 대한기계학회논문집B
    • /
    • 제31권10호
    • /
    • pp.848-854
    • /
    • 2007
  • The electrospray operated in the cone-jet mode can generate highly charged micro droplets in an almost uniform size at low flow rates. Therefore, the multiplexing system which can retain the characteristics of the cone-jet mode is inevitable for the electrospray application. This experiment reports the multiplexed grooved nozzle system with the extractor. The effects of the grooves and the extractor on the performance of the electrospray were evaluated through experiments. Using the grooved nozzle, the stable cone-jet mode can be achieved at the each groove in the grooved mode. Furthermore, the number of nozzles per unit area is increased by the extractor. The multiplexing density is 12 jets per $cm^2$ at 30 mm distance from the nozzle tip to the ground plate. The multiplexing system for the high flow rate electrospray is realized with the extractor which can diminish the space charge effect without sacrificing characteristics of the cone-jet mode.