• 제목/요약/키워드: Micro-Grid

검색결과 287건 처리시간 0.031초

빌딩마이크로그리드시스템용 하이브리드에너지시스템 전력제어 및 운영 (Power control and operation of Hybrid Energy System for Building Micro-Grid)

  • 조재훈;홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.37-41
    • /
    • 2009
  • In this paper, we propose to research the possibility of using a photovoltaic system and supercapacitor combined with a high speed microturbine. This hybrid energy system work as atand-alone mode or grid-connected mode as it will be a part of building micro-grid. Simple dynamic models of photovoltaic, microturbine systems and supercapacitor banks are proposed. their models are developed by Matlab/Simulink tool. Two important results are carried out to find power control effectiveness in case of with supercapacitor bank and without one. At least, simulation results show the effectiveness on the power control at AC busbar of hybrid energy system as building micro-grid system.

  • PDF

마이크로 전력계통에서 연료전지 발전시스템의 전기/열의 최적운영 기법 연구 (Optimal Electricity and Heat Production Strategies of Fuel Cell Device in a Micro-grid Energy System)

  • 이주원;박종배;김수덕;김창섭
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1093-1099
    • /
    • 2009
  • Alternative energy sources such as renewable energy like solar power systems, wind power systems, or fuel cell power systems has been the rising issue in the electrical power system. This paper discusses an economic study analysis of fuel cells in the korean electricity market. It includes the basic concept of a fuel cell and the korean electricity market. It also describes the need of renewable energy and how the fuel cell is connected with the local grid. This paper shows the impact of production and recovering thermal energy of a grid-connected fuel cell power system. The profit maximization approach has been structured including electrical power trade with the local grid and heat trade within the micro-grid. The strategies are evaluated using a local load that uses electric and thermal power which has different patterns between summer and winter periods. The solution algorithm is not newly developed one, but is solved by an application called GAMS. Results indicate the need and usefulness of a fuel cell power system.

일정 전력 추종 알고리즘이 적용된 DC 마이크로 그리드용 PV-ESS 통합형 모듈의 운영 기술 (Operation Technology of PV-ESS Integrated Module for DC Micro Grid with Constant Power Tracking Algorithm)

  • 류경;김준모;이정;원충연
    • 전력전자학회논문지
    • /
    • 제25권6호
    • /
    • pp.433-441
    • /
    • 2020
  • This study proposes a constant power tracking algorithm to compensate for the intermittent characteristics of Photovoltaic connected to a DC micro grid. A PV-ESS integrated module in which distributed ESS is additionally connected is utilized for the proposed algorithm. PV performs P&O MPPT control at all times. To supplement the intermittent characteristics of PV, the proposed constant power tracking algorithm maintains constant power by operating the distributed ESS of the PV-ESS integrated module in accordance with the output state of the PV. By performing PSIM simulation and an experiment, this study verifies the performance of the integrated module of PV-ESS for DC micro grids applying the constant power tracking algorithm.

Li-ion 배터리 충/방전 시스템의 안정적 운영에 관한 연구 (A Study on Stable Operation of Li-ion Battery Charging/Discharging System)

  • 여성대;한철규;조태일;이경량;김성권
    • 한국전자통신학회논문지
    • /
    • 제11권4호
    • /
    • pp.395-402
    • /
    • 2016
  • DC ${\mu}$-Grid 기반의 충/방전 시스템에서 배터리의 동작 변환 시, 망 전압의 fluctuation이 발생하게 되며, 과다한 fluctuation은 충/방전 시스템의 손상 및 고장을 일으킬 수 있다. 따라서 본 논문에서는 DC ${\mu}$-Grid 기반의 충/방전 시스템에서 fluctuation 완화용 커패시터의 적용 및 설계 포인트에 대하여 연구하였다. 컴퓨터 시뮬레이션 결과, 3개의 충전 배터리 set와 5개의 방전 배터리 set의 조건으로 운영되는 DC ${\mu}$-Grid 기반 충/방전 시스템에서 600V/35mF의 초기 값을 갖는 fluctuation 완화용 커패시터를 적용하였을 때 충/방전에 의한 fluctuation을 약 66.3% 감소시킬 수 있었으며, 추가적으로 초기 망 전압 안정화 시 발생하는 fluctuation 또한 약 73% 감소시킬 수 있었다.

가파도 마이크로그리드 신재생 에너지 전원 구성 방안 (Renewable Energy Configuration Plan of Micro Grid in Gapa Island)

  • 김동완;고지한;김승현;김호민;김일환
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.16-23
    • /
    • 2014
  • This paper presents a renewable energy configuration plan of Micro grid in Gapa Island. To analyze the characteristics of Micro grid, BESS (Battery Energy Storage System), PMSG (Permanent Magnet Synchronous Generator) and SCIG (Squirrel Cage Induction Generator) are first modelled. The PMSG and SCIG will operate with basis on the real power curve. when the total power demand is larger than the total power generation, the BESS will be operated and the SOC (State Of Charge) is reduced. If the value of SOC could drop down to limited value, the system may be broken because of the voltage drop of BESS. To solve this problem, a DG (Diesel Generator) is used to charge the BESS and keep the voltage value of BESS with in a allowance limit. This paper represents simulation result when PMSG, SCIG connected to the Micro grid installed in Gapa Island. The simulation is carry out by using PSCAD/EMTDC program with actual line constant and transformer parameter in Gapa Island.

A Stable Black-Start Strategy for a Stand-Alone DC Micro-Grid

  • Cha, Jae-Hun;Han, Yoon-Tak;Park, Kyung-Won;Oh, Jin-Hong;Choi, Tae-Seong;Ko, Jae-Hun;MAHIRANE, Philemon;An, Jae-Yun;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.30-37
    • /
    • 2018
  • Unlike an AC system, a DC system does not cause problems with synchronization, stability, reactive power, system losses, and cost. However, more research is still required for the application of DC Systems. This paper proposes a stable black-start strategy for a stand-alone DC micro-grid, which consists of an energy storage system, photovoltaic generator, wind-turbine generator, diesel generator, and DC loads. The proposed method is very important for avoiding inrush current and transient overvoltage in the power system equipment during restoration after a blackout. PSCAD/EMTDC software was used to simulate, analyze, and verify the method, which was found to be stable and applicable for a stand-alone DC micro-grid.

독립형 DC마이크로그리드 내 BESS용 4 LEG DC/DC 컨버터의 고장허용 및 고효율 제어에 관한 연구 (A Study on the Fault Tolerance and High Efficiency Control of 4 Leg DC/DC Converter for Battery Energy Storage System in Standalone DC Micro-grid)

  • 최정식;오승열;차대석;정동화
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1239-1248
    • /
    • 2018
  • This paper proposes a fault tolerant and high efficiency operation algorithm for a 4 LEG DC/DC converter for a battery energy storage system(BESS) forming a main power source in a standalone DC micro grid. The BESS for the main power supply in the stand-alone DC micro-grid is required to operate at high speed according to fault tolerant control and load by operating at all times. Fault-tolerance control changes the short-circuit fault to an open-circuit fault by using a fuse in case of leg fault in 4 legs, and operates stably through phase shift control. In addition, considering the loss of the power semiconductor, the number of LEG operation is adjusted to operate at high efficiency in the full load region. In this paper, fault tolerant control and high efficiency operation algorithm of DC/DC converter for BESS in standalone DC micro grid is presented and it is proved through simulation and experiment.

배전기기 전압계측 정밀도 평가시스템 개발 및 성능시험 (A Development and Performance Test of Voltage Measurement Accuracy Assessment System for Distribution Equipment)

  • 조진태;김주용;이학주;김재한
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.83-89
    • /
    • 2013
  • Power distribution system has been changed from radial system to closed loop or mesh system due to connection of distributed generation growth. Data from distribution equipments which are installed at distribution line is required to be accurate for the performance of DMS(Distribution Management System). This paper analyzes the voltage measurement data from distribution equipment. However, the results of the analysis are confirmed to have some errors in voltage measurement data from distribution equipment. These errors come from aging of voltage sensor in distribution equipment and inaccurate data transfer to FRTU(feeder remote terminal unit) through the controller. The main problem is that the voltage measurement data of distribution equipment can not be assessed after it's first installation at the distribution line. The voltage measurement accuracy assessment system is to assess the voltage measurement data from distribution equipment on hot-line. This study had a field test to verify the performance of system.

시간영역에서의 유효/무효전력을 이용한 마이크로그리드의 단독운전의 판단 알고리즘 (Islanding detection algorithm for a micro-grid based on the active and reactive power in the time domain)

  • 이영귀;이혜원;김연희;정태영;강용철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.145-146
    • /
    • 2011
  • A micro-grid (MG) is usually interconnected to the main grid through the dedicated line. Immediately after the removal of the grid supply, the MG should be disconnected and remain disconnected until the main grid is re-energized. It should detect islanding condition as soon as it happens to adjust the setting of the protection relays in the MG. This paper proposes an islanding detection algorithm for the MG based on the active and reactive power delivered to the dedicated line in the time domain. The performance of the proposed algorithm is verified under islanding conditions and fault conditions using the PSCAD/EMTDC simulator. The results indicate that the proposed algorithm can discriminate the islanding conditions from the various fault conditions.

  • PDF

마이크로소스 인덕터 크기 결정에 관한 기초연구 (Study on Micro-Sources Modeling and optimal series inductance size)

  • 김영섭;손광명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.137-139
    • /
    • 2003
  • Micro-Sources arc emerging as a providing environmentally friendly and reliable and effective solution. Micro-Source converter DC voltage of prime mover to AC voltage using voltage source inverter for interjecting with AC grid system. This paper studies optimal series inductance size for interjecting with AC grid system.

  • PDF