• 제목/요약/키워드: Micro manufacturer

검색결과 35건 처리시간 0.022초

Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density

  • Gaeta-Araujo, Hugo;Nascimento, Eduarda Helena Leandro;Brasil, Danieli Moura;Madlum, Daniela Verardi;Haiter-Neto, Francisco;Oliveira-Santos, Christiano
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.153-159
    • /
    • 2020
  • Purpose: This study was conducted evaluate the influence of reconstruction parameters of micro-computed tomography (micro-CT) images on bone mineral density (BMD) analyses. Materials and Methods: The sample consisted of micro-CT images of the maxillae of 5 Wistar rats, acquired using a SkyScan 1174 unit (Bruker, Kontich, Belgium). Each acquisition was reconstructed following the manufacturer's recommendations(standard protocol; SP) for the application of artifact correction tools(beam hardening correction [BHC], 45%; smoothing filter, degree 2; and ring artifact correction [RAC], level 5). Additionally, images were reconstructed with 36 protocols combining different settings of artifact correction tools (P0 to P35). BMD analysis was performed for each reconstructed image. The BMD values obtained for each protocol were compared to those obtained using the SP through repeated-measures analysis of variance with the Dunnett post hoc test(α=0.05). Results: The BMD values obtained from all protocols that used a BHC of 45% did not significantly differ from those obtained using the SP (P>0.05). The other protocols all yielded significantly different BMD values from the SP(P<0.05). The smoothing and RAC tools did not affect BMD values. Conclusion: BMD values measured on micro-CT images were influenced by the BHC level. Higher levels of BHC induced higher values of BMD.

소공인클러스터의 특성과 발달단계에 대한 비교연구: 서울시 창신 및 장위 의류봉제 클러스터를 중심으로 (Comparatie Study on the Characteristics and Development Stage of Micro Manufacturers Clusters: Focused on Apparel Sewing Clusters in Changsin and Jangwi, Seoul, Korea)

  • 정영수
    • 한국경제지리학회지
    • /
    • 제23권1호
    • /
    • pp.35-55
    • /
    • 2020
  • 소공인클러스터의 지원정책은 소공인클러스터의 지역적 특성을 반영해야 하지만, 유관기업의 통상적인 정보 수집을 기반으로 비슷한 정책만 내놓고 있다. 소공인클러스터의 지역적 특성이 파악이 안 되므로 지원정책에 반영이 되지 않고 있는 실정이다. 이에 본 연구는 소공인클러스터의 특성을 클러스터의 특징인 국지화, 네트워킹/착근성, 혁신시너지/집단학습의 형성요소로 분석하였으며, 분석된 형성요소를 기반으로 발달단계를 적용해 보았다. 같은 업종이어도 지역적 특성이 다를 수 있으므로, 서울시 의류봉제업의 대표적인 클러스터인 창신지역과 장위지역의 소공인클러스터를 지역적 특성과 발달단계로 비교 연구하였다. 의류봉제 소공인클러스터의 특성 분석 결과, 국지화에서 동종업체 집적은 창신지역이 장위지역보다 높게 나타났으며, 네트워킹/착근성에서 두 지역 모두 잘 형성되어 있었다. 하지만 혁신시너지/집단학습의 협업에서 창신지역은 디자이너 중심으로 장위지역은 소공인 중심으로 이루어져 있고, 박람회 및 세미나 참여와 샘플 및 제작에 있어 창신지역은 적극적인 반면 장위지역은 소극적으로 나타났다. 두 형성요소로 살펴본 결과, 두 지역의 소공인클러스터의 발달단계는 창신 의류봉제 소공인클러스터의 경우 산업지구를 넘어 혁신지구로 진행되고 있고, 장위 의류봉제 소공인클러스터는 산업지구에 머물러 있는 것으로 분석된다. 창신과 장위 의류봉제 소공인클러스터는 지속적인 성장을 위해서는 두 지역의 특성과 발달단계를 반영한 정부의 지원정책이 필요하다고 제언한다.

All-in-one adhesive의 다층적용이 미세인장결합강도에 미치는 영향 (THE EFFECT OF MULTIPLE APPLICATION ON MICROTENSILE BOND STRENGTH OF ALL-IN-ONE DENTIN ADHESIVE SYSTEMS)

  • 손성애;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.423-429
    • /
    • 2004
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. Flat occlusal dentin surfaces were prepared using low-speed diamond saw. In group I, Scotchbond Multipurpose (SM) was applied by manufacturer's recommendation. In group II, after Adper Prompt L-Pop was applied for 15s and light cured for 10s. the second coat was re-applied and light-cured. In group III, after light-curing the second layer. the third coat was re-applied and light-cured. Specimens bonded with a resin-composite were sectioned into resin-dentin stick for measuring the adhesive layer thickness by confocal laser scanning microscope and evaluating micro-tensile bond strength. The adhesive layers of three-step dentin adhesive system. 3 coats of Adper Prompt L-Pop had significantly thicker than SM. 2 coats of Adper Prompt L-Pop (p < 0.05). However. there was no significant differences in bond strengths between SM and 3 coats of Adper Prompt L-Pop (p > 0.05). And SM. 3 coats of Adper Prompt L-Pop had significantly higher than 2 coats of Adper Prompt L-Pop in bond strengths (p < 0.05).

Motion behavior research of liquid micro-particles filtration at various locations in a rotational flow field

  • Yan, Yan;Lin, Yuanzai;Cheng, Jie;Ni, Zhonghua
    • Structural Engineering and Mechanics
    • /
    • 제62권2호
    • /
    • pp.163-170
    • /
    • 2017
  • This study presents a particle-wall filtration model for predicting the particle motion behavior in a typical rotational flow field-filtration in blower system of cooker hood. Based on computational fluid dynamics model, air flow and particles has been simulated by Lagrangian-particle/ Eulerian-gas approaches and get verified by experiment data from a manufacturer. Airflow volume, particle diameter and local structure, which are related to the particle filtration has been studied. Results indicates that: (1) there exists an optimal airflow volume of $1243m^3/h$ related to the most appropriate filtration rate; (2) Diameter of particle is the significant property related to the filtration rate. Big size particles can represent the filtration performance of blower; (3) More than 86% grease particles are caught by impeller blades firstly, and then splashed onto the corresponding location of worm box internal wall. These results would help to study the micro-particle motion behavior and evaluate the filtration rate and structure design of blower.

신간선 전두부 디자인의 형상 변천 (The Changes of Shinkansen Vehicles' Nose Shape)

  • 김광명;한석우
    • 한국철도학회논문집
    • /
    • 제10권2호
    • /
    • pp.124-130
    • /
    • 2007
  • The emphasis of this paper is to find out the changes in length of nose in line with speed improvement and changes of the tendency in the shape of the nose in line with time series based on the Shinkansen vehicle. The length of the nose on the lines of high speed tends to get longer, however there is no proportion between the speed and the nose according to optimal design that was designed to reduce micro-pressure wave and air resistance. The Shinkansen vehicles, according to the shape, can be classified in to an Advanced Paraboloid shape, a Sharp-nosed shape, a Flat-nosed shape and an Organic Double-edged shape and is gradually changing in the trend of diversity and distinction. Hereafter, the design of the nose will be developed better into the design that will comprehend identity of manufacturer, region and culture on the basis of optimized aerodynamic shape.

배전용 폴리머애자의 현장열화 특성평가 (Characterization of Field-Aged Polymer Insulators for Distribution Power Systems)

  • 이병성;김찬영;한재홍
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.847-858
    • /
    • 2000
  • The aging characteristics of 2 kinds of 3 years field-aged distribution polymer insulators which were dismounted from 5 regions have been investigated by electrical test and material characterization. Although the tan $\delta$of specimens prepared from weathershed was increased with surface aging, the tan $\delta$and leakage current of real products had no difference between virgin and dismounted ones. Due to the aging, all dismounted polymer insulators had micro-cracks on the surface of weathershed and only the products of manufacturer B showed the reduction of OIT(oxidation induction time). But, there were no differences between virgin and dismounted products in contact angle and chemical structure. Therefore, it can be considered that the aging is only limited on the surface of dismounted polymer insulators and that NMR technique are very useful to evaluate the aging of polymer materials.

  • PDF

제조업경영의 국제비교에 관한 소고 (A Comparative Management Study Focused on Manufacturer)

  • 정태영
    • 산업경영시스템학회지
    • /
    • 제8권12호
    • /
    • pp.79-87
    • /
    • 1985
  • Environmental approach places the focus on a cause-and-effect relationship between the external environments and the internal business conditions. But that approach is an attempt to describe the characteristics of environmental constraints. W.J. Abernathy, K.B. Clark, and A.M. Kantrow attribute the Japanese carmaker's success to superiority in the manufacturing plant, especially in their process systems and work force management. They provide a paradigm for discussions of manufacturing competitiveness comparison. The structure of the paradigm has two main distinctions. The first is the division between analysis and prescription of a macro sort and those of a micro sort, the second is the division between analysis and prescription based on hardware and those based on software.

  • PDF

고선량률 근접조사치료용 이리듐-192 방사성동위원소의 교정방법 비교연구 (Comparison of Calibration Methods of $^{192}\textrm{Ir}$ Sources for High Dose Rate Brachytherapy)

  • 허현도;박성용;이레나;신동오;권수일;노준규;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.192-196
    • /
    • 2004
  • 본 연구는 국내에서 이용되고 있는 고선량률 근접치료기에 사용되는 Ir-192 선원에 대하여 Farmer type전리함과 우물형 전리함을 이용하여 선원의 세기를 측정하여 제조사에서 제공된 값과의 오차를 확인하고 두 증기간의 오차를 비교하였다. 동일한 Ir-192가 장착되어 가동 중인 6개의 병원의 고선량률 근접치료기(microSelctron, Nucletron, Netherlands)를 대상으로 선원의 모델별로 구분하여 상품화된 교정 Jig와 우물형 전리함 시스템을 이용, 선원의 세기를 측정하고 제조사에서 제공된 값과 비교하여 오차를 구하였다. 교정용 Jig를 이용한 선원 세기의 오차범위는 -2.40~+3.12%이고 우물형 전리함의 경우 오차범위는 -3.31~0.00%를 나타내었다. 측정 결과 두 장비 모두 제조사에서 제공된 값과 비교하였을 때 ${\pm}5%$의 오차를 넘지 않았으므로 임상 적용에는 문제가 없다. 외국의 사고 사례 보고에 따르면 계산 값에 의존하지 말고 새로운 선원이 교체될때 반드시 치료에 사용되기 전에 측정 도구를 이용하여 방사능의 세기를 측정하고 계산된 값과 비교하여 오차범위 내에서 일치하는지에 대한 확인 절차과정을 거치는 것이 필요하다.

  • PDF

인버터 에어컨 시스템의 역률보상을 위한 AC-DC 컨버터 제어 (AC-DC Converter Control for Power Factor Correction of Inverter Air Conditioner System)

  • 박귀근;최재원
    • 제어로봇시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.154-162
    • /
    • 2007
  • In this paper, we propose a new AC-DC converter control method to comply with harmonics regulation(IEC 61000-3) effective for the inverter system of an air conditioner whose power consumption is less than 2,500W. There are many different ways of AC-DC converter control, but this paper focuses on the converter control method that is adopting an input reactor with low cost silicon steel core to strengthen cost competitiveness of the manufacturer. The proposed control method controls input current every half cycle of the line frequency to get unit power factor and at the same time to reduce switching loss of devices and acoustic noise from reactor. This kind of converter is known as a Partial Switching Converter(PSC). In this study, theoretical analysis of the PSC has been performed using Matlab/Simulink while a 16-bit micro-processor based converter has been used to perform the experimental analysis. In the theoretical analysis, electrical circuit models and equations of the PSC are derived and simulated. In the experiments, micro-processor controls input current to keep the power factor above 0.95 by reducing the phase difference between input voltage and current and at the same time to maintain a reference DC-link voltage against voltage drop which depends on DC-link load. Therefore it becomes possible to comply with harmonic regulations while the power factor is maximized by optimizing the time of current flow through the input reactor for every half cycle of line frequency.

정밀저울을 이용한 원자힘 현미경 캔티레버의 특성평가 (Atomic Force Microscope Probe Calibration by use of a Commercial Precision Balance)

  • 김민석;최인묵;박연규;최재혁;김종호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.637-640
    • /
    • 2005
  • In this paper, we investigate the characteristics of a piezoresistive AFM cantilever in the range of $0\~30{\mu}N$ by using nano force calibrator (NFC), which consists of a high precision balance with resolution of 1 nN and 1-D fine positioning stage. Brief modeling of the cantilever is presented and then, the calibration results are shown. Tests revealed a linear relationship between the probing force and sensor output (resistance change), and the force vs. deflection. From this relationship, the force constant of the cantilever was calculated to 3.45 N/m with a standard deviation of 0.01 N/m. It shows that there is a big difference between measured and nominal spring constant of 1 N/m provided by the manufacturer s specifications.

  • PDF