• 제목/요약/키워드: Micro Valve

검색결과 105건 처리시간 0.025초

초절전형 마이크로 밸브 특성해석 및 실험 (Characteristic Analysis and experiment of the Low Power Consumption type Micro Valve)

  • 김동수;박상운;김현섭;류재섭;이원희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.876-881
    • /
    • 2004
  • In this study, A special quality analysis and experiment for low power consumption type pneumatic on-off micro valve was performed. And flow characteristics of the micro valve by stroke change was numerically investigated. As a result, it is shown that magnetic force(2.4N) is exerted enough to move poppet with 0.3mm stroke with 0.01 seconds of response time, and that there is no magnetic force emitted by yoke. Under the condition of poppet stroke smaller than about 0.8mm, dynamic pressure acts to poppet wall up to supply pressure level. But, that is decreasing to 40% when poppet stroke is 0.8mm.

  • PDF

초절전형 마이크로 밸브 해석 및 설계 (Analysis and Design of the Low Power Consumption type Micro Valve)

  • 김동수
    • 유공압시스템학회논문집
    • /
    • 제1권2호
    • /
    • pp.15-19
    • /
    • 2004
  • In this study, Design and simulation for low power consumption type pneumatic on-off micro valve was performed. And flow characteristics of the micro valve by stroke change was numerically investigated. As a result, it is shown that magnetic force(6.8N) is exerted enough to move poppet with 0.438mm stroke with 0.01 seconds of response time, and that there is no magnetic force emitted by yoke. Under the condition of poppet stroke smaller than about 0.4mm, dynamic pressure acts to poppet wall up to supply pressure level. But, that is decreasing to 40% when poppet stroke is 0.8mm.

  • PDF

마이크로 관류수차의 상수도 관로시스템 적용에 관한 연구 (Application of Micro Cross-Flow Turbine to Water Supply System)

  • 최영도;쿠로카와준이치
    • 한국유체기계학회 논문집
    • /
    • 제9권3호
    • /
    • pp.36-43
    • /
    • 2006
  • Recently, micro hydropower and it's useful utilization are taking a growing interest as a countermeasure of global worming by carbon dioxide and exhaustion of fossil fuel. The purpose of this study is to investigate the possibility of extracting micro hydropower wasted by a valve in water supply system using micro cross-flow hydraulic turbine. In order to fulfill the functions of controlling flow rate and pressure in substitute for the valve, air and water are supplied into an air suction hole which is installed on the side wall of micro cross-flow hydraulic turbine. The results show that in case of supplying a lot of air into the air suction hole, about 50% of flow rate and relatively high value of loss coefficient are controlled by the turbine. Moreover, including high possibility of applying the micro cross-flow turbine to water supply system, extended application of the turbine to the water discharge system of drainage and irrigation canal.

마이크로 가공시스템을 위한 언로딩 매니퓰레이터 개발 (Development of an unloading manipulator for micro manufacturing system)

  • 윤덕원;신동익;김진호;한창수;이낙규;이혜진;류영선
    • 한국공작기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.187-192
    • /
    • 2007
  • In this paper we present a 3-DOF manipulator of which task is to unload the product from a micro factory. The micro factory developed by KITECH presses sheet metal to produce a micro valve that is used for micro pump. Our research is focused on the development of a small-sized unloading manipulator which works in the narrow workspace between the dies. We have implemented pick-and-place task with vacuum pressure and 3-DOF motion with stepping motors. We present the design procedures and analysis required in each module.

레져버에 압력이 가해지는 환경에서의 미소 정량 토출 펌프의 개발 (Development of Constant Delivery Micro Pump in a Variable Pressure Environment for Intrathecal Drug Administration System)

  • 이태경;이철수;정유석;박경근
    • 한국생산제조학회지
    • /
    • 제26권4호
    • /
    • pp.387-394
    • /
    • 2017
  • This paper develops a pump system for patient with chronic pain or cancer. The pump module is consists of two micro-valve and membrane. The micro-valve is operated by a solenoid. With two solenoid valves which are connected via a drug transport line, the inlet and outlet are completely blocked. A silicon rubber membrane located between the two valves makes the flow-rate constant without any backflow. This pump module can control the flow-rate of drugs by controlling the time that the valves are opened and closed. The reservoir consists of a drug chamber and a gas chamber. As the gas chamber encloses the drug chamber, propellant gas which is injected into the gas chamber pressurizes the drug chamber regardless of volume of the drug chamber. To design the pump module, analysis a constant efficiency test, and accuracy test for the pump module were conducted.

레이저 가공 폴리머 마이크로 유체 장치 (Laser Process of Polymer Micro Fluidic Devices)

  • 김주한
    • 한국정밀공학회지
    • /
    • 제23권2호
    • /
    • pp.129-137
    • /
    • 2006
  • Polymer micro-fluidic devices were fabricated with laser processes. A UV laser and a femto laser were used to machine polymer micro-fluidic structures directly. This laser direct machining process suits the need of rapid prototyping, as in many applications changes from the original design are often required. As examples, two polymer micro-systems were developed: a micro-check valve and a micro diffuser pump. The micro fluidic devices can be applied for many applications such as clinical diagnostics and drug delivery. Advantages and disadvantages using polymers as a material for micro-fluidic applications are discussed.

초내열합금 밸브의 성형공정 설계 및 미세조직 분석 (Process Design in Forging of Ultra-Heat Resisting Alloy and Analysis of Micro-Structure)

  • 강범수;최민식;배진영;박노광
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1996년도 추계학술대회논문집
    • /
    • pp.99-104
    • /
    • 1996
  • A proform for engine valve was designed by finite element method. In the preform design of engine valve, various initial billets are simulated for better preform to get sound final product. Here a preform is design to get desirable metal flow in the forming so that the final product has more uniform strain distribution. after forming. The analysis of the micro-structure of the value formed through the designed process was also performed and result was compared with that of simulation.

  • PDF

초소형 향 분사 모듈의 제작 (Fabrication of a Micro Scent Injector)

  • 박태규;양상식;김영식;이상우
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권12호
    • /
    • pp.633-638
    • /
    • 2001
  • The paper presents the fabrication and test of a micro scent injector module. A micro scent injector module consists of an injector fabricated by micromachining, a scent cartridge and a controller. If a scent injection signal triggers the controller, it heats the scent liquid in the injector chamber and a scent liquid is vaporized. The increased vapor pressure opens a normally closed boss valve, and the scent vapor is injected through the opened nozzle. The liquid volume injected by the fabricated module is about $1\muell$ for one second at 2 W.

  • PDF