On-the-job Training Gap between regular and non-regular Workers and Wage Effects (정규직-비정규직 간 훈련격차와 임금효과)

  • Oh, Ho-Young
    • Journal of Labour Economics
    • /
    • v.43 no.3
    • /
    • pp.33-61
    • /
    • 2020
  • The purpose of this study is to analyze the disparity in on-the-job training between regular and non-regular workers and to compare the wage effects of on-the-job training. Using the Korean micro data from the Programme for the International Assessment of Adult Competencies(PIAAC) published by OECD, Propensity Score Method(PSM) is applied to overcome the endogeneity problem. The average treatment effect(ATT) on the training participation is analyzed, using non-regular workers as treatment group and regular workers as comparison group. Odds ratios of non-regular employees' training participation compared to regular employees shows 0.67 times after constructing matching sample and this means that non-regular workers are facing a disadvantageous training opportunity compared to regular workers. In order to estimate the wage effect of on-the-job training, the average treatment effect(ATT) of on-the-job training on average wages for regular workers and non-regular workers is estimated respectively. I find insignificant wage effect from on-the-job training among regular workers and significant positive effect on non-regular worker's wage from on-the-job training.

  • PDF

Effects of cementless fixation of implant prosthesis: A finite element study

  • Lee, Hyeonjong;Park, Soyeon;Kwon, Kung-Rock;Noh, Gunwoo
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.341-349
    • /
    • 2019
  • PURPOSE. A novel retentive type of implant prosthesis that does not require the use of cement or screw holes has been introduced; however, there are few reports examining the biomechanical aspects of this novel implant. This study aimed to evaluate the biomechanical features of cementless fixation (CLF) implant prostheses. MATERIALS AND METHODS. The test groups of three variations of CLF implant prostheses and a control group of conventional cement-retained (CR) prosthesis were designed three-dimensionally for finite element analysis. The test groups were divided according to the abutment shape and the relining strategy on the inner surface of the implant crown as follows; resin-air hole-full (RAF), resin-air hole (RA), and resin-no air hole (RNA). The von Mises stress and principal stress were used to evaluate the stress values and distributions of the implant components. Contact open values were calculated to analyze the gap formation of the contact surfaces at the abutment-resin and abutment-implant interfaces. The micro-strain values were evaluated for the surrounding bone. RESULTS. Values reflecting the maximum stress on the abutment were as follows (in MPa): RAF, 25.6; RA, 23.4; RNA, 20.0; and CR, 15.8. The value of gap formation was measured from 0.88 to 1.19 ㎛ at the abutment-resin interface and 24.4 to 24.7 ㎛ at the abutment-implant interface. The strain distribution was similar in all cases. CONCLUSION. CLF had no disadvantages in terms of the biomechanical features compared with conventional CR implant prosthesis and could be successfully applied for implant prosthesis.

A Study on the Crevice Corrosion for Ferritic Stainless Steel (페라이트 스테인리스강의 틈부식에 대한 연구)

  • Baik Shin-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.10 no.1 s.20
    • /
    • pp.51-54
    • /
    • 2004
  • In recently days, the breed fish farm is increased in the beach side for farming fish. In such a farm, the heater is requested for preventing freezing in cold season. The heating material are requested high corrosion resistance and strength for endurance high corrosive salt and pressure. In case of low corrosion resistance and/or strength, the heating element shall be broke down and eventually make spillage or leaking contaminated salt. In the most cases, crevice corrosion is localized form of corrosion usually associated with a stagnant solution on the micro-environmental level. In this study, the crevice corrosion of Ferritic type 430 stainless steel is investigated. The size of specimen is $15{\times}20{\times}3mmt$. Test solution is 1N H2SO4 + 0.05N NaCl. The artificial crevice gap size is $0.24{\times}3{\times}15mmL$. Crevice corrosion is measured under applied voltage 300mV(SCE) to the external surface. the result of this study showed that 1) the induced time for initiation of crevice is 750seconds, 2) potential is dropped in the crevice from the top of gap opening from -320 to -399mV. The result confirmed that the potential drop(IR mechanism) in the crevice is one of mechanism for crevice corrosion.

  • PDF

Income Inequality Decomposed by Age, Period and Cohort Effects: A Comparison of the Capital and Non-Capital Regions (연령, 시간, 코호트효과를 고려한 소득 불평등: 수도권과 비수도권 간 비교)

  • Jeong, Jun Ho
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.166-181
    • /
    • 2020
  • This paper attempts to compare and analyze the intensity, trend, and regional gap of income inequality, capitalizing upon the Age-Period-Cohort model which considers age, time and cohort effects, with the 1998-2018 Korea Labor Panel (KLIPS) survey data for respondents living in the Capital and Non-Capital Regions. The main analysis results are as follows. First, in the case of both cohort and age effects, those in their 50~60s, including the so-called baby boomers and '386 generation' living in the Capital Region, have relatively lower income inequality effect compared to that of other age groups and cohorts in the Non-Capital Region. Second, the micro-individual characteristics cannot be ignored to account for a regional gap in income inequality, but rather the effects of structural and institutional omitted variables and the social discrimination effects of individual characteristics variables are more significant in explaining it. Overall, intra-and inter-cohort income inequalities appear to overlap.

Development of Pressure Sensor for Identifying Guinea Pig's Large Intestinal Motility Caused by Drug (약물 투여에 따른 기니피그 대장 운동 측정을 위한 압력센서 개발)

  • Park, Jae-Soon;Park, Jung-Ho;Kim, Eung-Bo;Cho, Sung-Hwan;Jang, Su-Jeong;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.1
    • /
    • pp.23-29
    • /
    • 2016
  • In this paper, in order to quantify the peristalsis occurrence in a guinea pig's large intestine, a miniaturized air-gap capacitive pressure sensor was fabricated through micro-electro-mechanical system (MEMS). The proposed pressure sensor is a two-layered biocompatible polyimide substrate consisting of an air-gap capacitive plates between the substrates. The proposed pressure sensor was designed with a careful consideration of the structure and motility mechanism of the guinea pig's large intestine. Artificial pellets were mounted on a prototype pressure sensor to provide some redundancies in the form of size and shape of the guinea pig feces. Capacitance of a prototype sensor was recorded to be 2.5 ~ 3 pF. This capacitance value was later converted to count value using a lab fabricated data conversion system. Sensitivity of the pressure sensor was recorded to be below 1 mmHg per atmospheric pressure. During in vivo testing, artificial peristalsis caused by drug injection was measured by inserting the prototype pressure sensor into the guinea pig's large intestine and pressure data obtained due to artificial peristalsis was graphed using a labview program. The proposed pressure sensor could measure the pressure changes in the proximal, medial, and distal parts of the large intestine. The results of the experiment confirmed that pressure changes of guinea pig's large intestine was proportional to the degree of drug injection.

Heat Transfer Enhancement in Channel Flow by a Streamwise-Periodic Array of Rotating Circular Cylinders (주기적으로 배열된 회전하는 원형 실린더를 이용한 채널유동의 열전달 증진)

  • Jeong, Taekyeong;Yang, Kyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.999-1008
    • /
    • 2014
  • In this study, we consider the heat transfer characteristics of channel flow in the presence of an infinite streamwise array of equispaced identical rotating circular cylinders. This flow configuration can be regarded as a model representing a micro channel or an internal heat exchanger with cylindrical vortex generators. A numerical parametric study has been carried out by varying Reynolds number based on the bulk mean velocity and the cylinder diameter, and the gap between the cylinders and the channel wall for some selected angular speeds. The presence of the rotating circular cylinders arranged periodically in the streamwise direction causes a significant topological change of the flow, leading to heat transfer enhancement on the channel walls. More quantitative results as well as qualitative physical explanations are presented to justify the effectiveness of varying the gap to enhance heat transfer from the channel walls.

Study on the Electromagnetic Excitation System for the Measurement of Dynamic Coefficients of Air Foil Bearing for High Speed Rotor (초고속 회전체용 공기 포일 베어링의 동특성 계수 측정을 위한 전자석 가진장치에 관한 연구)

  • Park, Cheol-Hoon;Choi, Sang-Kyu;Ham, Sang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.3
    • /
    • pp.18-25
    • /
    • 2013
  • Recently the requirement of long-term mobile energy source for mobile robot or small-sized unmanned vehicle is highly increased, and the micro turbine generator(MTG) which is known to have high energy and power density is under development. MTG is designed to have air foil bearing and high speed rotor of which operating speed is 400,000rpm. In the development stage of high speed rotor and bearing, stability analysis for the full operational speed range is essential and the dynamic coefficients such as stiffness and damping coefficients of bearing depending on the rotational speed are required for that. Although perturbation method is usually used to identify the dynamic coefficients, it's not easy to give the perturbation to the high speed rotating rotor. In this study, we present the dynamic coefficients measurement system for air foil bearing which consists of electromagnets, gap sensors, high speed motor and controller. This measurement system can exert the sine sweep force to the rotor-bearing, measure the displacement of rotor and get FRF(Frequency response function) of rotor-bearing. The least square estimation method is applied to identify the dynamic coefficients of bearing from the measured frequency response at the different rpm and the identified dynamic coefficients for the wide rotational speed range are presented.

Ge-doped Boro-Phospho-Silicate Glass Micro-lens Array Produced by Thermal Reflow (가열용융 방법에 의한 Ge-BPSG 마이크로렌즈 어레이 제작)

  • Jeong, Jin-ho;Oh, Jin-Gyeong;Choi, Jun-Seok;Choi, Gi-Seon;Lee, Hyeong-Jong;Bae, Byeong-Seong
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.340-344
    • /
    • 2005
  • Microlens cells of Ge-doped BPSG (Boro-Phospho-Silicate Glass) are fabricated by dicing the film produced by FHD (Flame Hydrolysis Deposition). Microlens arrays of $53.4{\mu}m$ square unit are produced by the thermal reflow of the diced unit cells at $1200^{\circ}C$. The gap between the microlenses was about $70{\mu}m,$ and the thickness of the produced lens was about $28.4{\mu}m$. We analyzed the reflowed shape of the microlens cell by an image-process technique, and the focal length was about $62.2{\mu}m$. This method of fabricating a microlens is simple and inexpensive compared to the conventional method using the photolithographic process. Also, the control of the radius of curvature of the microlens is easier and a more precise microlens way of various types can be fabricated using this method.

Microarray Analysis of Oxygen-Glucose-Deprivation Induced Gene Expression in Cultured Astrocytes

  • Joo, Dae-Hyun;Han, Hyung-Soo;Park, Jae-Sik
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.10 no.5
    • /
    • pp.263-271
    • /
    • 2006
  • Since astrocytes were shown to play a central role in maintaining neuronal viability both under normal conditions and during stress such as ischemia, studies of the astrocytic response to stress are essential to understand many types of brain pathology. The micro array system permitted screening of large numbers of genes in biological or pathological processes. Therefore, the gene expression patterns in the in vitro model of astrocytes following exposure to oxygen-glucose deprivation (OGD) were evaluated by using the micro array analysis. Primary astrocytic cultures were prepared from postnatal Swiss Webster mice. The cells were exposed to OGD for 4 hrs at $37^{\circ}C$ prior to cell harvesting. From the cultured cells, we isolated mRNA, synthesized cDNA, converted to biotinylated cRNA and then reacted with GeneChips. The data were normalized and analyzed using dChip and GenMAPP tools. After 4 hrs exposure to OGD, 4 genes were increased more than 2 folds and 51 genes were decreased more than 2 folds compared with the control condition. The data suggest that the OGD has general suppressive effect on the gene expression with the exception of some genes which are related with ischemic cell death directly or indirectly. These genes are mainly involved in apoptotic and protein translation pathways and gap junction component. These results suggest that microarray analysis of gene expression may be useful for screening novel molecular mediators of astrocyte response to ischemic injury and making profound understanding of the cellular mechanisms as a whole. Such a screening technique should provide insights into the molecular basis of brain disorders and help to identify potential targets for therapy.

An experimental study of the strength and internal structure of solder joint of fixed partial denture (가공의치(架工義齒) 납착부(蠟着部)의 강도(强度)와 내부구조(內部構造)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Park, Sang-Nam;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.23 no.1
    • /
    • pp.39-59
    • /
    • 1985
  • The purpose of this study was to investigate how gap distances of 0.13mm, 0.15mm, 0.20mm, and 0.30mm affects solder joint strength from gold alloys and nickel-chromium base alloys and to examine the composition of solder gold, the solder joint of gold alloys and nickel-chromium base alloys. The tensile test specimens were prepared in the split stainless steel mold with a half dumbbell shape 2.5mm in diameter and l2mm in length. 6 pairs of specimens of each gap distance group of gold alloys and nickel-chromium base alloys were made and 48 pairs of all specimens were soldered with solder gold of 666 fineness. All soldered specimens were machined to a uniform diameter and then a tensile load was applied at a cross-head speed of 0.10mm/min using Instron Universal Testing Machine, Model 1115. The fractured specimens at solder gold of solder joint fracture with each gap distance of 0.13mm, 0.15mm, 0.20mm, and 0.30mm were examined under the Scanning Electron Microscope, JSM-35c and the composition of solder gold, the solder joint of gold alloys and nickel-chromium base alloys was analyzed by Electron Probe Micro Analyzer. The results of this study were obtained as follows: 1. In case of soldering of gold alloys, the tensile strength between gold alloys showed $37.33{\pm}2.52kg/mm^2$ at 0.13, $39.14{\pm}3.35kg/mm^2$ at 0.15mm, $43.76{\pm}2.97kg/mm^2$ at 0.20mm, and $49.18{\pm}4.60kg/mm^2$ at 0.30mm. There was statistically significant difference at each gap distance, and so the greater increase of gap distance showed the greater tensile strength. 2. In case of soldering of nickel-chromium base alloys, the tensile strength between nickel-chromium base alloys showed $34.84{\pm}4.26kg/mm^2$ at 0.13mm, $37.25{\pm}2.49kg/mm^2$ at 0.15mm, $42.91{\pm}4.32kg/mm^2$ at 0.20mm, and $46.93{\pm}4.21kg/mm^2$ at 0.30mm. There was not statistically significant difference only between 0.13mm and 0.15mm and bet ween 0.20 mm and 0.30mm, but generally the greater increase of gap distance showed the greater tensile strength. 3. The greater increase of gap distance shoed less porosities in solder gold at solder joint fracture. 4. In solder gold Au, Cu, Ag, Zn, and Sn were composed and Au and Cu were mostly distributed uniformly. 5. In solder joints of solder gold and gold alloys Au, Cu, Ag, Zn, and Sn were composed in solder gold and Au, Cu, Ag, Pt, and Pd were composed in gold alloys. Au and Cu of solder gold and gold alloys were mostly distributed uniformly and the diffusion of other elements except Pt and Pd around the solder joint was not almost found. In solder joints of solder gold and nickel-chromium base alloys Au, Cu, Ag, Zn, and Sn were composed in solder gold and Ni, Cr, and Al were composed in nickel-chromium base alloys. Au and Cu of solder gold and Ni and Cr of nickel-chromium base alloys were mostly distributed uniformly and the diffusion of other elements except Cr around the solder joint was not almost found.

  • PDF