• Title/Summary/Keyword: Micro Display

Search Result 480, Processing Time 0.027 seconds

Characteristics of Display -type Spherical Mirror Analyzer (평면 표시형 구면경분석기의 분광 특성)

  • ;A.kurokawa;S.Ichimura;J. Toth;K.Yoshihara
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.3
    • /
    • pp.188-193
    • /
    • 1996
  • A new display -type spherical mirror analyzer has been characterized in terms of the performance and the auger spectra taken by using it. The final goal with the analyzer is to devleop SET(Surface Electron Spectroscopic Tomography) which is capable to provide a 3-dimensional layer-by-layer information nondestructively. This kind of analyzer was originally designed by H.Daimon. The main feature is to display 2-dimensional electronic structures directly onto a screen. In our case, an external micro-electron beam was employed as an excitation source. However, this invokes various problems because of the interference between the electron beam and the analyzer. The problems have been solved through the optimization of various parameters of the analyzer.

  • PDF

Measurement of Electron Temperature and Plasma Density in Coplanar AC Plasma Display Panels.

  • Cho, Il-Ryong;Moon, Min-Yook;Ryu, Chung-Gon;Choi, Myung-Chul;Choi, Eun-Ha
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.748-751
    • /
    • 2003
  • The electron temperature and plasma density in coplanar alternating-current plasma display panels (AC-PDPs) have been experimentally investigated by a micro Langmuir probe and the high speed discharge images in this experiment.

  • PDF

Development of ECG-NIBP Patient Monitoring System (ECG-NIBP 환자감시장치 개발)

  • Kim, N.H.;Shin, W.H.;Lee, G.K.;Ra, S.W.;Kim, G.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.315-318
    • /
    • 1997
  • The ECG-NIBP patient monitor consist of Noninvasive Blood Pressure(NIBP) module that have micro controller inside. This module transfer data by serial communication to the main processor. This system apply the fuzzy inflating method to reduce the blood pressure measuring time, and moving artifact removing algorithm, several parameters used or more accurate measurement. The ECG monitor use the Digital Signal Processor(DSP) or digital filtering, peak detection, heart rate calculation. This system also offer convenient user interface by rotary key, menu bar. With 7" CRT display, auxiliary TFT LCD display adapted to display information on wide screen.

  • PDF

Remote Phosphor with Array of Blue Light-emitting Diodes on Board Used in Liquid-crystal Backlight Module

  • Huang, Hsin-Tao;Tsai, Chuang-Chuang;Huang, Yi-Pai;Lin, Jeremy;Chang, Wen-Chi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.79-82
    • /
    • 2009
  • This work presents a novel lighting technology based on a YAG:$Ce^{3+}$ phosphor converter with micro line lenticular structure, to accompany an array of bare LED chips on a board. This technology is especially effective in TFT-LCD backlight applications as it offers the advantages of high light radiation efficiency, low color deviation, uniform luminance distribution and compact backlight thickness. Additionally, the proposed configuration is low-cost, can be manufactured quickly, and can be mass-produced economically.

  • PDF

Numerical Simulation on Dispersion of Fume Micro-Particles by Particle Suction Flows in Laser Surface Machining (입자 석션유동에 따른 레이저 표면가공의 마이크로 흄 오염입자 산포 특성 해석연구)

  • Kyoungjin Kim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.1-6
    • /
    • 2023
  • In CO2 laser surface machining of plastic films in modern display manufacturing, scattering of fume particles could be a major source of well-recognized film surface contamination. This computational fluid dynamics research investigates the suction air flow patterns over a film surface as well as the dispersion of micron-sized fume particles with low-Reynolds number particle drag model. The numerical results show the recirculatory flow patterns near laser machining point on film surface and also over the surface of vertical suction slot, which may hinder the efficient removal of fume particles from film surface. The dispersion characteristics of fume particles with various particle size have been tested systematically under different levels of suction flow intensity. It is found that suction removal efficiency of fume particles heavily depends on the particle size in highly nonlinear manners and a higher degree of suction does not always results in more efficient particle removal.

  • PDF

A Disposable BioChip for Single Cell Manipulation

  • Yoon, Euisik
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2004.10a
    • /
    • pp.1-15
    • /
    • 2004
  • o Various microfluidic components including mixromixers and micropumps have been developed for disposable biochip applications. o Single cell capturing, positioning and nanoliter drug injection chip has been demostrated. o Multi-channel, two-dimensional micro-well array has been fabricated and cell capturing and specific reagent injection have been performed.

  • PDF

High-Contrast Projection Screen

  • Kuo, Huei Pei
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1430-1432
    • /
    • 2008
  • We have developed a high-contrast ambient-light rejection projection screen with surface micro-structures for front and rear projection displays with an oblique-angle projector. We have fabricated prototype screens that show a better than $10{\times}$ improvement in contrast compared to a matte-white screen under various ambient lighting conditions and screen luminance.

  • PDF

Design of Multiple Temperature Measurement Device for Performance Evaluation of Incubator (보육기 성능 평가를 위한 다접점 온도측정기의 설계)

  • Kim, W.K.;Kim, N.H.;Huh, J.M.;Yoo, S.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.05
    • /
    • pp.86-88
    • /
    • 1991
  • A micro-computer based system has been designed to evaluate the performance of infant incubators. The measurement system used a hybrid of analog electronics for amplification, integration and switches and micro-computer for data storage, data display, and control of relay. This approach has been applied to measure the warm-up time, temperature stability, temperature change due to open/close of door and portholes, and temperature distribution on the mattress. The micro-computer provides on-line access of multi-point temperature data.

  • PDF

Printability of synthesized Silver Nano sol in Micro-patterning of Electrode on ITO Glass

  • Ryu, Beyong-Hwan;Park, Han-Sung;Byun, Jong-Hoon;Choi, Young-Min;Kong, Ki-Jeong;Lee, Jeong-O;Chang, Hyun-Ju
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.981-984
    • /
    • 2004
  • We have studied a printability of synthesized silver nano solon ITO glass substrate. The highly concentrated polymeric dispersant-assisted silver nano sol was prepared by variation of molecular weight and control of initial nucleation and growth of silver nanoparticles, to achive dispersion stability and controlling the size of silver nanoparticles. The synthesized silver nano-sol was tested for printability to explore the possibility of micro-electrodes patterning on ITO glass substrate. The silver micro-electrode with 50${\sim}100{\mu}m$ line width was formed on ITO glass substrate.

  • PDF

Computer-Assisted Multiple Temperature Measurement of Infant Incubator (컴퓨터에 의한 신생아용 보육기의 다접점 온도측정)

  • Kim, Won-Ki;Kim, Nan-Hyun;Yoo, Sun-Kuk
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.9-18
    • /
    • 1991
  • A micro- computer system has been designed to evaluate the performance of commercial infant incubator and to develope the temperature controller of new incubator. The measure- ment system used a hybrid of analog electronics for amplification, integration, and switches and micro-computer for data storage, data display, and control of relay. This approach has been applied to measure the warm-up time, temperature stability, open/close door and port- holes, and temperature distribution on the mattress. The micro-computer provides on-line ac cess of multi-point temperature data, simplifies the analog part of the circuit and gives the flexibility.

  • PDF