• Title/Summary/Keyword: Micro Cooling System

Search Result 106, Processing Time 0.036 seconds

A Review on Cooling Technologies for Micro and Miniature Devices and Systems

  • Yoon, Jae-Sung;Choi, Jong-Won;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.2
    • /
    • pp.70-77
    • /
    • 2007
  • As electric and mechanical devices have been miniaturized and highly integrated, heat generation per unit volume has been greatly increased. Therefore, effective cooling methods for micro and miniature systems have emerged as critical issues nowadays and a lot of studies have been carried out to find an optimum cooling strategy. This paper reviews recent researches on the cooling technologies which are mainly based on micro-fabrication processes. Design, development, experiments and numerical analysis of various cooling devices are discussed and their characteristics, problems and advantages are compared.

Effect of Groove and Channel Size on the Thermal Transport Capacity of Micro-Capillary Pumped Loop for Mobile Electronic Device Cooling System (모바일 전자장비 냉각용 Micro-CPL내 형상크기변화에 따른 열성능 해석)

  • Kim, Byeong-Gi;Seo, Jeong-Se;Hwang, Geon;Mun, Seok-Hwan;Bae, Chan-Hyo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.329-334
    • /
    • 2005
  • As more high power wide band gap devices are being utilized. the thermal management issues associated with these devices need to be resolved. High power small devices dissipate excessive heat that must be cooled, but traditional cooling methods are insufficient to provide such a cooling means. This paper will evaluate a micro-capillary pumped loop thermal management system that is incorporated into the shim of the device, taking advantage of phase-change to increase the thermal conductivity of the system. The results of the modeling of the thermal management system will be discussed.

  • PDF

A Study on Automatic Sensing Device for Water Leakage of Cooling Pipe at Blast Furnace by Use The Electronic System (전자제어 장치를 이용한 용광로 냉각관 누수 지동 감지장치 개발에 관한 연구)

  • Kang, Chang-Soo;Kang, Ki-Seong
    • 전자공학회논문지 IE
    • /
    • v.46 no.4
    • /
    • pp.25-30
    • /
    • 2009
  • The cooling water circulation pipes had been used to drop the temperature of refractory outside shell of blast furnace by cooling plate or stave type. They were attacked by surrounding CO gas and it was the cause that they were corroded and the water inflow in the refractory due to leakage of water. So, the life of refractory material was shorten and changed for the worse the conditions of blast furnace. The automatic sensing device for water leakage of cooling pipe was developed to check the position of trouble by use the micro-process system when cooling water leak and then CO gas will be inflowed into the cooling pipe at the leakage position. The inflowed CO gas will be detected in the micro-process system and delivered the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave the water leakage part immediately and then deliver the signal to main control room by use the micro-process system and wireless-radio relay station. This system will develop the working condition from manual system to unmanned auto alarm system.

A Study on the Automatic Sensing Device for Gas Leakage of Cooling Plate Using the Microprocessor System

  • Wang, Jee-Seok;Yoon, Hee-Jong;Kang, Ki-Seong;Kim, Jong-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.329-334
    • /
    • 2011
  • The cooling water circulation plates had been used to drop the temperature of refractory outside shell of common cooling system by using cooling plate or stave type. When they are attacked by surrounding gas, they are corroded and the water flows in the refractory due to leakage of water. So, the life of refractory material is shortened and changed due to the worse conditions of cooling system. The automatic sensing device for water leakage of cooling plate is developed to check the position of trouble by using the microprocessor system when cooling water leak and gas are flowed into the cooling plate through the leakage position. The flowed gas is detected in the micro-process system which delivers the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave against the water leakage part immediately and then deliver the signal to main control room by using the microprocessor system and wireless-radio relay station. This system will be developed in changing the working condition from manual system to unmanned auto alarm system.

Fabrication of Micro-Heatsink using Nanotemplate (나노 템플레이트를 이용한 마이크로 히트 싱크)

  • 함은주;손원일;홍재민
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.1
    • /
    • pp.7-11
    • /
    • 2003
  • The semiconductor chips or electronic components generate heat, which causes malfunction of the parts when it was not cooled properly. Bulky heat sink and cooling fan are used to get rid of the heat. However, with this bulky system, it is hard to integrate the electronics system in a small scale. The cooling efficiency of the system depends on the surface area of the heat sink, thermal conductivity of the material and the method of integration. In order to develop a novel cooling system, a micro-heatsink with a large surface area while retaining small volume was fabricated by electroless deposition of gold/copper inside a Track-etched membrane. The structure of the micro-heatsink was investigated using SEM or optical microscope. It was also found that the micro-heatsink is more efficient than a flat copper plate.

  • PDF

Cooling System Control of Building Integrated Photovoltaic Generation Using Micro-controller (마이크로 컨트롤러를 이용한 BIPV 발전의 냉각시스템 제어)

  • Choi, Jung-Sik;Ko, Jae-Sub;Jung, Chul-Ho;Kim, Do-Yeon;Jung, Byung-Jin;Park, Ki-Tae;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1120-1121
    • /
    • 2008
  • This paper is proposed cooling system of BIPV(Building Integrated Photovoltaic) by micro-controller. The output power of PV generation system is not systematically tracked and influenced by various factors; solar irradiance, solar cell temperature. The temperature of solar module should be minimized to increase electrical output. Therefore, it is proposed that micro-controller cools to decrease temperature of solar module using thermoelement. The validity of this paper is proved by comparing solar module temperature of cooling system and un-cooling system.

  • PDF

Energy Performance Evaluation of Building Micro-grid System Including Micro-turbine in Hospital Buildings (마이크로터빈이 포함된 빌딩마이크로그리드시스템의 병원건물의 에너지성능평가)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.279-283
    • /
    • 2009
  • Distributed generation(DG) of combined cooling, heat. and power(CCHP)has been gaining momentum in recent year as efficient, secure alternative for meeting increasing energy demands. This paper presents the energy performance of microturbine CCHP system equipped with an absorption chiller by modelling it in hospital building. The orders of study were as following. 1)The list and schedule of energy consumption equipment in hospital were examined such as heating and cooling machine, light etc. 2) Annual report of energy usage and monitoring data were examined as heating, cooling, DHW, lighting, etc. 3) The weather data in 2007 was used for simulation and was arranged by meteorological office data in Daejeon. 4) Reference simulation model was built by comparison of real energy consumption and simulation result by TRNSYS and ESP-r. The energy consumption pattern of building were analyzed by simulation model and energy reduction rate were calculated over the cogeneration. As a result of this study, power generation efficiency of turbine was about 30% after installing micro gas turbine and lighting energy as well as total electricity consumption can be reduced by 40%. If electricity energy and waste heat in turbine are used, 56% of heating energy and 67% of cooling energy can be reduced respectively, and total system efficiency can be increased up to 70%.

  • PDF

Feasibility of using biogas in a micro turbine for supplying heating, cooling and electricity for a small rural building

  • Rajaei, Gh.;Atabi, F.;Ehyaei, M.A.
    • Advances in Energy Research
    • /
    • v.5 no.2
    • /
    • pp.129-145
    • /
    • 2017
  • In this study, the use of a micro gas turbine system using biogas to supply heating, cooling and electricity loads of a rural building located in rural area around Tehran has been studied. Initially, the amount of energy needed by the farmhouse was calculated and then the number of needed microturbines was determined. Accordingly, the amount of substances entering biogas digester as well as tank volume were determined. The results of this study showed that village house loads including electrical, heating and cooling and hot water loads can be supplied by using a microturbine with a nominal power of 30 kW and $33.5m^3/day$ of biogas. Digester tank and reservoir tank volumes are $67m^3$ and $31.2m^3$, respectively. The cost of electricity produced by this system is 0.446 US$/kWh. For rural area in Iran, this system is not compatible with micro gas turbine and IC engine system use urban natural gas due to low price of natural gas in Iran, but it can be compatible by wind turbine, photovoltaic and hybrid system (wind turbine& photovoltaic) systems.

Development of a Blended Corrosion, Scale and Micro-Organism Inhibitor for Open Recirculating Cooling System

  • Choi, Dong-Jin;You, Seung-Jae;Kim, Jung-Gu;Hwang, Woo-Suk
    • Corrosion Science and Technology
    • /
    • v.4 no.3
    • /
    • pp.89-94
    • /
    • 2005
  • This paper presents the results of a study that was undertaken to optimize the ratio of the components of a new multi-component inhibitor blend composed of orthophosphate/ phosphonates/ acrylate copolymer/ isothiazolone. The effects of newly developed inhibitor on carbon steel dissolution in synthetic cooling water were studied through weight loss tests, electrochemical tests, scale tests, and micro-organism tests. The obtained results were compared to blank (uninhibited specimen) and showed that developed inhibitor revealed very good corrosion, scale, and micro-organism inhibition simultaneously. All measurements indicated that the efficiency of the blended mixture exceeded 90 %. The inhibitive effects arose from formation of protective films which might contain calcium phosphate, calcium phosphonate, and iron oxide. The nature of protective films formed on the carbon steel was studied by scanning electron microscopy (SEM) and auger electron spe ctroscopy (AES). Inhibitor used in this study appeared to have better performance for scale inhibition due to their superior crystal modification effect and excellent calcium carbonate scale inhibition properties. The effect of inhibitor on microorganisms was evaluated through minimum inhibitory concentration (MIC) test. All kinds of micro-organisms used in this study were inhibited under 78ppm concentration of inhibitor.